--- manual/s_examples/tracer_adjsens/co2sens.tex 2001/10/25 18:36:54 1.2 +++ manual/s_examples/tracer_adjsens/co2sens.tex 2001/11/13 18:19:18 1.3 @@ -1,4 +1,4 @@ -% $Header: /home/ubuntu/mnt/e9_copy/manual/s_examples/tracer_adjsens/Attic/co2sens.tex,v 1.2 2001/10/25 18:36:54 cnh Exp $ +% $Header: /home/ubuntu/mnt/e9_copy/manual/s_examples/tracer_adjsens/Attic/co2sens.tex,v 1.3 2001/11/13 18:19:18 adcroft Exp $ % $Name: $ \section{Example: Centennial Time Scale Sensitivities} @@ -176,7 +176,7 @@ \subsubsection{Numerical Stability Criteria} The Laplacian dissipation coefficient, $A_{h}$, is set to $400 m s^{-1}$. -This value is chosen to yield a Munk layer width \cite{Adcroft_thesis}, +This value is chosen to yield a Munk layer width \cite{adcroft:95}, \begin{eqnarray} \label{EQ:munk_layer} @@ -190,7 +190,7 @@ \noindent The model is stepped forward with a time step $\delta t=1200$secs. With this time step the stability -parameter to the horizontal Laplacian friction \cite{Adcroft_thesis} +parameter to the horizontal Laplacian friction \cite{adcroft:95} \begin{eqnarray} \label{EQ:laplacian_stability} @@ -216,7 +216,7 @@ \\ \noindent The numerical stability for inertial oscillations -\cite{Adcroft_thesis} +\cite{adcroft:95} \begin{eqnarray} \label{EQ:inertial_stability} @@ -227,7 +227,7 @@ limit for stability. \\ -\noindent The advective CFL \cite{Adcroft_thesis} for a extreme maximum +\noindent The advective CFL \cite{adcroft:95} for a extreme maximum horizontal flow speed of $ | \vec{u} | = 2 ms^{-1}$ @@ -241,7 +241,7 @@ \\ \noindent The stability parameter for internal gravity waves -\cite{Adcroft_thesis} +\cite{adcroft:95} \begin{eqnarray} \label{EQ:cfl_stability}