/[MITgcm]/MITgcm_contrib/submesoscale/code/ini_grid.F
ViewVC logotype

Contents of /MITgcm_contrib/submesoscale/code/ini_grid.F

Parent Directory Parent Directory | Revision Log Revision Log | View Revision Graph Revision Graph


Revision 1.1 - (show annotations) (download)
Sat May 31 00:13:54 2008 UTC (17 years, 1 month ago) by dimitri
Branch: MAIN
Adding ini_grid.F and obcs_check.F (checkpoint59r) in preparation to
fixing dxC and dyC in the overlap regions.

1 C $Header: /u/gcmpack/MITgcm/model/src/ini_grid.F,v 1.31 2006/11/28 22:47:13 jmc Exp $
2 C $Name: $
3
4 #include "PACKAGES_CONFIG.h"
5 #include "CPP_OPTIONS.h"
6
7 CBOP
8 C !ROUTINE: INI_GRID
9
10 C !INTERFACE:
11 SUBROUTINE INI_GRID( myThid )
12 C !DESCRIPTION:
13 C These arrays are used throughout the code in evaluating gradients,
14 C integrals and spatial avarages. This routine is called separately
15 C by each thread and initializes only the region of the domain it is
16 C "responsible" for.
17
18 C !USES:
19 IMPLICIT NONE
20 #include "SIZE.h"
21 #include "EEPARAMS.h"
22 #include "PARAMS.h"
23 #include "GRID.h"
24 #ifdef ALLOW_MNC
25 #include "MNC_PARAMS.h"
26 #endif
27 #ifdef ALLOW_MONITOR
28 #include "MONITOR.h"
29 #endif
30
31 C !INPUT/OUTPUT PARAMETERS:
32 C myThid :: my Thread Id number
33 INTEGER myThid
34 CEOP
35
36 C === Functions ====
37 LOGICAL MASTER_CPU_IO
38 EXTERNAL MASTER_CPU_IO
39
40 C !LOCAL VARIABLES:
41 C msgBuf :: Informational/error message buffer
42 CHARACTER*(MAX_LEN_MBUF) msgBuf
43 #ifdef ALLOW_MNC
44 INTEGER i
45 #endif
46
47 C load grid spacing (vector) from files
48 CALL LOAD_GRID_SPACING( myThid )
49
50 C Set up reference vertical profile (vector) for state variables
51 C jmc: this call will not stay here but will move to S/R INITIALISE_FIXED
52 C (a better place) once anelatic initialisation is cleaned-up.
53 CALL INI_REFERENCE_STATE( myThid )
54
55 C Set up vertical grid and coordinate system
56 CALL INI_VERTICAL_GRID( myThid )
57
58 C Two examples are shown in this code. One illustrates the
59 C initialization of a cartesian grid. The other shows the
60 C inialization of a spherical polar grid. Other orthonormal grids
61 C can be fitted into this design. In this case custom metric terms
62 C also need adding to account for the projections of velocity
63 C vectors onto these grids. The structure used here also makes it
64 C possible to implement less regular grid mappings. In particular:
65 C o Schemes which leave out blocks of the domain that are
66 C all land could be supported.
67 C o Multi-level schemes such as icosohedral or cubic
68 C grid projectedions onto a sphere can also be fitted
69 C within the strategy we use.
70 C Both of the above also require modifying the support
71 C routines that map computational blocks to simulation
72 C domain blocks.
73
74 C Set up horizontal grid and coordinate system
75 IF ( usingCartesianGrid ) THEN
76 CALL INI_CARTESIAN_GRID( myThid )
77 ELSEIF ( usingSphericalPolarGrid ) THEN
78 CALL INI_SPHERICAL_POLAR_GRID( myThid )
79 ELSEIF ( usingCurvilinearGrid ) THEN
80 CALL INI_CURVILINEAR_GRID( myThid )
81 ELSEIF ( usingCylindricalGrid ) THEN
82 CALL INI_CYLINDER_GRID( myThid )
83 ELSE
84 _BEGIN_MASTER(myThid)
85 WRITE(msgBuf,'(2A)') 'S/R INI_GRID: ',
86 & 'No grid coordinate system has been selected'
87 CALL PRINT_ERROR( msgBuf , myThid)
88 STOP 'ABNORMAL END: S/R INI_GRID'
89 _END_MASTER(myThid)
90 ENDIF
91
92 #ifdef ALLOW_MONITOR
93 IF ( MASTER_CPU_IO(myThid) ) THEN
94 C-- only the master thread is allowed to switch On/Off mon_write_stdout
95 C & mon_write_mnc (since it's the only thread that uses those flags):
96
97 IF (monitor_stdio) THEN
98 mon_write_stdout = .TRUE.
99 ELSE
100 mon_write_stdout = .FALSE.
101 ENDIF
102 mon_write_mnc = .FALSE.
103 #ifdef ALLOW_MNC
104 IF (useMNC .AND. monitor_mnc) THEN
105 DO i = 1,MAX_LEN_MBUF
106 mon_fname(i:i) = ' '
107 ENDDO
108 mon_fname(1:12) = 'monitor_grid'
109 CALL MNC_CW_SET_UDIM(mon_fname, 1, myThid)
110 mon_write_mnc = .TRUE.
111 ENDIF
112 #endif /* ALLOW_MNC */
113
114 ENDIF
115
116 C Print out statistics of each horizontal grid array (helps when
117 C debugging)
118 CALL MON_PRINTSTATS_RS(1,xC,'XC',myThid)
119 CALL MON_PRINTSTATS_RS(1,xG,'XG',myThid)
120 CALL MON_PRINTSTATS_RS(1,dxC,'DXC',myThid)
121 CALL MON_PRINTSTATS_RS(1,dxF,'DXF',myThid)
122 CALL MON_PRINTSTATS_RS(1,dxG,'DXG',myThid)
123 CALL MON_PRINTSTATS_RS(1,dxV,'DXV',myThid)
124 CALL MON_PRINTSTATS_RS(1,yC,'YC',myThid)
125 CALL MON_PRINTSTATS_RS(1,yG,'YG',myThid)
126 CALL MON_PRINTSTATS_RS(1,dyC,'DYC',myThid)
127 CALL MON_PRINTSTATS_RS(1,dyF,'DYF',myThid)
128 CALL MON_PRINTSTATS_RS(1,dyG,'DYG',myThid)
129 CALL MON_PRINTSTATS_RS(1,dyU,'DYU',myThid)
130 CALL MON_PRINTSTATS_RS(1,rA,'RA',myThid)
131 CALL MON_PRINTSTATS_RS(1,rAw,'RAW',myThid)
132 CALL MON_PRINTSTATS_RS(1,rAs,'RAS',myThid)
133 CALL MON_PRINTSTATS_RS(1,rAz,'RAZ',myThid)
134 CALL MON_PRINTSTATS_RS(1,angleCosC,'AngleCS',myThid)
135 CALL MON_PRINTSTATS_RS(1,angleSinC,'AngleSN',myThid)
136
137 IF ( MASTER_CPU_IO(myThid) ) THEN
138 mon_write_stdout = .FALSE.
139 mon_write_mnc = .FALSE.
140 ENDIF
141 #endif /* ALLOW_MONITOR */
142
143 C-- Everyone else must wait for the grid to be set
144 _BARRIER
145
146 RETURN
147 END

  ViewVC Help