/[MITgcm]/MITgcm_contrib/natl_12/code/ini_theta.F
ViewVC logotype

Annotation of /MITgcm_contrib/natl_12/code/ini_theta.F

Parent Directory Parent Directory | Revision Log Revision Log | View Revision Graph Revision Graph


Revision 1.1 - (hide annotations) (download)
Tue Aug 5 21:22:43 2003 UTC (21 years, 11 months ago) by cnh
Branch: MAIN
CVS Tags: HEAD
Adding set of files for 1/12 Atlantic configuration

1 cnh 1.1 C $Header: /u/u0/gcmpack/MITgcm/model/src/ini_theta.F,v 1.16 2001/09/26 18:09:15 cnh Exp $
2     C $Name: $
3    
4     #include "CPP_OPTIONS.h"
5    
6     CBOP
7     C !ROUTINE: INI_THETA
8     C !INTERFACE:
9     SUBROUTINE INI_THETA( myThid )
10     C !DESCRIPTION: \bv
11     C *==========================================================*
12     C | SUBROUTINE INI_THETA
13     C | o Set model initial temperature field.
14     C *==========================================================*
15     C | There are several options for setting the initial
16     C | temperature file
17     C | 1. Inline code
18     C | 2. Vertical profile ( uniform T in X and Y )
19     C | 3. Three-dimensional data from a file. For example from
20     C | Levitus or from a checkpoint file from a previous
21     C | integration.
22     C | In addition to setting the temperature field we also
23     C | set the initial temperature tendency term here.
24     C *==========================================================*
25     C \ev
26    
27     C !USES:
28     IMPLICIT NONE
29     C === Global variables ===
30     #include "SIZE.h"
31     #include "EEPARAMS.h"
32     #include "PARAMS.h"
33     #include "GRID.h"
34     #include "DYNVARS.h"
35     #include "FFIELDS.h"
36    
37     C !INPUT/OUTPUT PARAMETERS:
38     C == Routine arguments ==
39     C myThid - Number of this instance of INI_THETA
40     INTEGER myThid
41    
42     C !LOCAL VARIABLES:
43     C == Local variables ==
44     C iC, jC - Center of domain
45     C iD, jD - Disitance from domain center.
46     C rad - Radius of initial patch
47     C rD - Radial displacement of point I,J
48     C iG, jG - Global coordinate index
49     C bi,bj - Loop counters
50     C I,J,K
51     INTEGER iC, jC, iD, jD
52     INTEGER iG, jG
53     INTEGER bi, bj
54     INTEGER I, J, K, localWarnings
55     _RL rad, rD
56     CHARACTER*(MAX_LEN_MBUF) msgBuf
57     CEOP
58    
59     C-- Initialise temperature field to the vertical reference profile
60     DO bj = myByLo(myThid), myByHi(myThid)
61     DO bi = myBxLo(myThid), myBxHi(myThid)
62     DO K=1,Nr
63     DO J=1-Oly,sNy+Oly
64     DO I=1-Olx,sNx+Olx
65     theta(I,J,K,bi,bj) = tRef(K)
66     ENDDO
67     ENDDO
68     ENDDO
69     ENDDO
70     ENDDO
71    
72     IF ( hydrogThetaFile .NE. ' ' ) THEN
73     _BEGIN_MASTER( myThid )
74     CALL READ_FLD_XYZ_RL( hydrogThetaFile, ' ', theta, 0, myThid )
75     _END_MASTER(myThid)
76     _EXCH_XYZ_R8(theta,myThid)
77     ENDIF
78    
79     C Apply mask and test consistancy
80     localWarnings=0
81     DO bj = myByLo(myThid), myByHi(myThid)
82     DO bi = myBxLo(myThid), myBxHi(myThid)
83     DO K=1,Nr
84     DO J=1,sNy
85     DO I=1,sNx
86     IF (hFacC(I,J,K,bi,bj).EQ.0) theta(I,J,K,bi,bj) = 0.
87     IF (hFacC(I,J,K,bi,bj).NE.0.AND.theta(I,J,K,bi,bj).EQ.0.
88     & .AND. tRef(k).NE.0.) THEN
89     localWarnings=localWarnings+1
90     WRITE(6,*) I,J,K,bi,bj
91     ENDIF
92     thetaRef(i,j,k,bi,bj) = theta(i,j,k,bi,bj)
93     ENDDO
94     ENDDO
95     ENDDO
96     ENDDO
97     ENDDO
98     _EXCH_XYZ_R8(thetaRef,myThid)
99     IF (localWarnings.NE.0) THEN
100     WRITE(msgBuf,'(A,A)')
101     & 'S/R INI_THETA: theta = 0 identically. If this is intentional',
102     & 'you will need to edit ini_theta.F to avoid this safety check'
103     CALL PRINT_ERROR( msgBuf , myThid)
104     STOP 'ABNORMAL END: S/R INI_THETA'
105     ENDIF
106    
107     CALL PLOT_FIELD_XYZRL( theta, 'Initial Temperature' ,
108     & Nr, 1, myThid )
109    
110     RETURN
111     END

  ViewVC Help