/[MITgcm]/MITgcm/pkg/seaice/SEAICE_FFIELDS.h
ViewVC logotype

Diff of /MITgcm/pkg/seaice/SEAICE_FFIELDS.h

Parent Directory Parent Directory | Revision Log Revision Log | View Revision Graph Revision Graph | View Patch Patch

revision 1.5 by dimitri, Tue Feb 18 05:33:55 2003 UTC revision 1.6 by dimitri, Wed Apr 30 07:04:08 2003 UTC
# Line 13  C     uwind     :: Surface (10-m) zonal Line 13  C     uwind     :: Surface (10-m) zonal
13  C                  > 0 for increase in uVel, which is west to  C                  > 0 for increase in uVel, which is west to
14  C                      east for cartesian and spherical polar grids  C                      east for cartesian and spherical polar grids
15  C                  Typical range: -10 < uwind < 10  C                  Typical range: -10 < uwind < 10
16  C                  Northeast B-grid U point  C                  Southwest B-grid U point
17  C  C
18  C     vwind     :: Surface (10-m) meridional wind velocity in m/s  C     vwind     :: Surface (10-m) meridional wind velocity in m/s
19  C                  > 0 for increase in vVel, which is south to  C                  > 0 for increase in vVel, which is south to
20  C                      north for cartesian and spherical polar grids  C                      north for cartesian and spherical polar grids
21  C                  Typical range: -10 < vwind < 10  C                  Typical range: -10 < vwind < 10
22  C                  Northeast B-grid V point  C                  Southwest B-grid V point
23  C  C
24  C     evap      :: Evaporation in m/s  C     evap      :: Evaporation in m/s
25  C                  > 0 for increase in salt (ocean salinity)  C                  > 0 for increase in salt (ocean salinity)
26  C                  Typical range: 0 < evap < 2.5e-7  C                  Typical range: 0 < evap < 2.5e-7
27  C                  Northeast B-grid tracer point  C                  Southwest B-grid tracer point
28  C  C
29  C     precip    :: Precipitation in m/s  C     precip    :: Precipitation in m/s
30  C                  > 0 for decrease in salt (ocean salinity)  C                  > 0 for decrease in salt (ocean salinity)
31  C                  Typical range: 0 < precip < 5e-7  C                  Typical range: 0 < precip < 5e-7
32  C                  Northeast B-grid tracer point  C                  Southwest B-grid tracer point
33  C  C
34  C     runoff    :: River and glacier runoff in m/s  C     runoff    :: River and glacier runoff in m/s
35  C                  > 0 for decrease in salt (ocean salinity)  C                  > 0 for decrease in salt (ocean salinity)
36  C                  Typical range: 0 < runoff < ????  C                  Typical range: 0 < runoff < ????
37  C                  Northeast B-grid tracer point  C                  Southwest B-grid tracer point
38  C  C
39  C     atemp     :: Surface (2-m) air temperature in deg K  C     atemp     :: Surface (2-m) air temperature in deg K
40  C                  Typical range: 200 < atemp < 300  C                  Typical range: 200 < atemp < 300
41  C                  Northeast B-grid tracer point  C                  Southwest B-grid tracer point
42  C  C
43  C     aqh       :: Surface (2m) specific humidity in kg/kg  C     aqh       :: Surface (2m) specific humidity in kg/kg
44  C                  Typical range: 0 < aqh < 0.02  C                  Typical range: 0 < aqh < 0.02
45  C                  Northeast B-grid tracer point  C                  Southwest B-grid tracer point
46  C  C
47  C     swdown    :: Downward shortwave radiation in W/m^2  C     swdown    :: Downward shortwave radiation in W/m^2
48  C                  > 0 for increase in theta (ocean warming)  C                  > 0 for increase in theta (ocean warming)
49  C                  Typical range: 0 < swdown < 450  C                  Typical range: 0 < swdown < 450
50  C                  Northeast B-grid tracer point  C                  Southwest B-grid tracer point
51  C  C
52  C     lwdown    :: Downward longwave radiation in W/m^2  C     lwdown    :: Downward longwave radiation in W/m^2
53  C                  > 0 for increase in theta (ocean warming)  C                  > 0 for increase in theta (ocean warming)
54  C                  Typical range: 50 < lwdown < 450  C                  Typical range: 50 < lwdown < 450
55  C                  Northeast B-grid tracer point  C                  Southwest B-grid tracer point
56  C  C
57  C  C
58  C     NOTES:  C     NOTES:

Legend:
Removed from v.1.5  
changed lines
  Added in v.1.6

  ViewVC Help
Powered by ViewVC 1.1.22