/[MITgcm]/MITgcm/pkg/ocn_compon_interf/cpl_readparms.F
ViewVC logotype

Contents of /MITgcm/pkg/ocn_compon_interf/cpl_readparms.F

Parent Directory Parent Directory | Revision Log Revision Log | View Revision Graph Revision Graph


Revision 1.1 - (show annotations) (download)
Mon Dec 15 02:49:09 2003 UTC (20 years, 6 months ago) by jmc
Branch: MAIN
CVS Tags: checkpoint52l_pre, checkpoint52e_pre, hrcube4, checkpoint52n_post, checkpoint52j_post, checkpoint52e_post, checkpoint52l_post, checkpoint52k_post, checkpoint53b_pre, checkpoint52m_post, checkpoint53a_post, checkpoint53b_post, checkpoint53, checkpoint52d_post, checkpoint52f_post, hrcube5, checkpoint52i_post, checkpoint52j_pre, checkpoint52i_pre, checkpoint52h_pre, checkpoint52f_pre, hrcube_2, hrcube_3
Ocean interface S/R to exchange with the coupler.

1 C $Header: $
2 C $Name: $
3
4 #include "PACKAGES_CONFIG.h"
5 #include "CPP_OPTIONS.h"
6
7 CBOP
8 C !ROUTINE: CPL_READPARMS
9 C !INTERFACE:
10 SUBROUTINE CPL_READPARMS( myThid )
11
12 C !DESCRIPTION: \bv
13 C *==========================================================*
14 C | S/R CPL_READPARMS
15 C | o Read Coupling parameters that control import/export
16 C | from/to the coupler layer
17 C *==========================================================*
18 C | this version is specific to 1 component (ocean)
19 C *==========================================================*
20 C \ev
21
22 C !USES:
23 IMPLICIT NONE
24
25 C == Global variables ===
26
27 #include "SIZE.h"
28
29 #include "EEPARAMS.h"
30 #include "PARAMS.h"
31 #include "CPL_PARAMS.h"
32
33 C !INPUT/OUTPUT PARAMETERS:
34 C == Routine Arguments ==
35 C myThid - Number of this instance
36 INTEGER myThid
37 CEOP
38
39 #ifdef COMPONENT_MODULE
40
41 C Functions
42 INTEGER ILNBLNK
43
44 C == Local Variables ==
45 C msgBuf :: Informational/error meesage buffer
46 C iUnit :: Work variable for IO unit number
47 C k :: loop counter
48 C iL :: Work variable for length of file-name
49 CHARACTER*(MAX_LEN_MBUF) msgBuf
50 INTEGER iUnit, k, iL
51
52 C---+----1----+----2----+----3----+----4----+----5----+----6----+----7-|--+----|
53
54 C-- Coupling parameters:
55 C useImportHFlx :: True => use the Imported HeatFlux from couler
56 C useImportFW :: True => use the Imported Fresh Water flux fr cpl
57 C useImportTau :: True => use the Imported Wind-Stress from couler
58 C cpl_taveFreq :: Frequency^-1 for time-Aver. output (s)
59 NAMELIST /CPL_OCN_PARAM/
60 & useImportHFlx, useImportFW, useImportTau,
61 & cpl_taveFreq
62
63 C---+----1----+----2----+----3----+----4----+----5----+----6----+----7-|--+----|
64
65 C- Set default value:
66 useImportHFlx = .TRUE.
67 useImportFW = .TRUE.
68 useImportTau = .TRUE.
69 cpl_taveFreq = taveFreq
70
71 _BEGIN_MASTER(myThid)
72
73 WRITE(msgBuf,'(A)') ' CPL_READPARMS: opening data.cpl'
74 CALL PRINT_MESSAGE(msgBuf,standardMessageUnit,SQUEEZE_RIGHT,1)
75
76 CALL OPEN_COPY_DATA_FILE( 'data.cpl', 'CPL_READPARMS',
77 O iUnit, myThid )
78
79 C-- Read parameters from open data file:
80
81 C- Parameters for coupling interface:
82 READ(UNIT=iUnit,NML=CPL_OCN_PARAM)
83
84 WRITE(msgBuf,'(A)')
85 & ' CPL_READPARMS: finished reading data.cpl'
86 CALL PRINT_MESSAGE(msgBuf,standardMessageUnit,SQUEEZE_RIGHT,1)
87
88 C-- Close the open data file
89 CLOSE(iUnit)
90
91 C---+----1----+----2----+----3----+----4----+----5----+----6----+----7-|--+----|
92 C-- Check parameters and model configuration
93
94 C- If land_taveFreq is positive, then must compile the land-diagnostics code
95 #ifndef ALLOW_TIMEAVE
96 IF (cpl_taveFreq.GT.0.) THEN
97 WRITE(msgBuf,'(A)')
98 & 'CPL_READPARMS: cpl_taveFreq > 0 but ALLOW_TIMEAVE undefined'
99 CALL PRINT_ERROR( msgBuf, myThid)
100 WRITE(msgBuf,'(2A)')
101 & 'Re-compile with: #define ALLOW_TIMEAVE',
102 & ' or -DALLOW_TIMEAVE'
103 CALL PRINT_ERROR( msgBuf, myThid)
104 STOP 'ABNORMAL END: S/R CPL_READPARMS'
105 ENDIF
106 #endif /* ALLOW_TIMEAVE */
107
108 C- derive other parameters:
109
110 C---+----1----+----2----+----3----+----4----+----5----+----6----+----7-|--+----|
111 C-- Print out parameter values :
112
113 iUnit = standardMessageUnit
114 WRITE(msgBuf,'(A)') ' '
115 CALL PRINT_MESSAGE(msgBuf,iUnit,SQUEEZE_RIGHT,1)
116 WRITE(msgBuf,'(A)') '// ==================================='
117 CALL PRINT_MESSAGE(msgBuf,iUnit,SQUEEZE_RIGHT,1)
118 WRITE(msgBuf,'(A)') '// Coupling package parameters :'
119 CALL PRINT_MESSAGE(msgBuf,iUnit,SQUEEZE_RIGHT,1)
120 WRITE(msgBuf,'(A)') '// ==================================='
121 CALL PRINT_MESSAGE(msgBuf,iUnit,SQUEEZE_RIGHT,1)
122
123 C- namelist LAND_MODEL_PAR:
124 CALL WRITE_0D_L( useImportHFlx, INDEX_NONE,
125 & 'useImportHFlx=',
126 & ' /* use Imported Heat-Flx fr Coupler on/off flag */')
127 CALL WRITE_0D_L( useImportFW , INDEX_NONE,
128 & 'useImportFW =',
129 & ' /* use Imported Fresh-Water fr Cpl. on/off flag */')
130 CALL WRITE_0D_L( useImportTau , INDEX_NONE,
131 & 'useImportTau =',
132 & ' /* use Imported Wind-Stress fr Cpl. on/off flag */')
133 CALL WRITE_0D_R8( cpl_taveFreq, INDEX_NONE, 'cpl_taveFreq =',
134 & ' /* Frequency^-1 for time-Aver. output (s) */')
135
136 C---+----1----+----2----+----3----+----4----+----5----+----6----+----7-|--+----|
137
138 _END_MASTER(myThid)
139
140 C-- Everyone else must wait for the parameters to be loaded
141 _BARRIER
142
143 #endif /* COMPONENT_MODULE */
144
145 RETURN
146 END

  ViewVC Help