/[MITgcm]/MITgcm/pkg/monitor/monitor_ad.F
ViewVC logotype

Contents of /MITgcm/pkg/monitor/monitor_ad.F

Parent Directory Parent Directory | Revision Log Revision Log | View Revision Graph Revision Graph


Revision 1.12 - (show annotations) (download)
Sat Jul 28 20:04:15 2012 UTC (11 years, 9 months ago) by jmc
Branch: MAIN
CVS Tags: checkpoint64a, checkpoint64c, checkpoint64b, checkpoint64e, checkpoint64d, checkpoint63q, checkpoint63r, checkpoint63s, checkpoint64
Changes since 1.11: +105 -45 lines
- implement new method (copy+adexch) for monitor of main model ad-vars ;
- remove monitor of ad-CFL (or CFL of ad-velocity ? not clear what it was)

1 C $Header: /u/gcmpack/MITgcm/pkg/monitor/monitor_ad.F,v 1.11 2012/07/06 23:06:31 jmc Exp $
2 C $Name: $
3
4 #include "MONITOR_OPTIONS.h"
5 #include "AD_CONFIG.h"
6
7 C---+----1----+----2----+----3----+----4----+----5----+----6----+----7-|--+----|
8 CBOP
9 C !ROUTINE: MONITOR
10
11 C !INTERFACE:
12 SUBROUTINE ADMONITOR(
13 I myTime, myIter, myThid )
14
15 C !DESCRIPTION:
16 C Monitor key dynamical variables: calculate over the full domain
17 C some simple statistics (e.g., min,max,average) and write them.
18
19 C !USES:
20 IMPLICIT NONE
21 #include "SIZE.h"
22 #include "EEPARAMS.h"
23 #include "PARAMS.h"
24 #include "GRID.h"
25 #include "MONITOR.h"
26 #ifdef ALLOW_MNC
27 # include "MNC_PARAMS.h"
28 #endif
29 #ifdef ALLOW_AUTODIFF
30 # include "AUTODIFF_PARAMS.h"
31 # ifdef ALLOW_AUTODIFF_MONITOR
32 # include "adcommon.h"
33 # endif
34 #endif
35
36 C !INPUT PARAMETERS:
37 _RL myTime
38 INTEGER myIter
39 INTEGER myThid
40 CEOP
41
42 #if (defined (ALLOW_ADJOINT_RUN) || defined (ALLOW_ADMTLM))
43 #if (defined (ALLOW_AUTODIFF) && defined (ALLOW_AUTODIFF_MONITOR))
44
45 C === Functions ====
46 LOGICAL DIFFERENT_MULTIPLE
47 EXTERNAL DIFFERENT_MULTIPLE
48 LOGICAL MASTER_CPU_IO
49 EXTERNAL MASTER_CPU_IO
50
51 C !LOCAL VARIABLES:
52 CHARACTER*(MAX_LEN_MBUF) msgBuf
53 _RL dummyRL(6)
54 INTEGER k
55 _RL var2Du(1-OLx:sNx+OLx,1-OLy:sNy+OLy,nSx,nSy)
56 _RL var2Dv(1-OLx:sNx+OLx,1-OLy:sNy+OLy,nSx,nSy)
57 _RL var3Du(1-OLx:sNx+OLx,1-OLy:sNy+OLy,Nr,nSx,nSy)
58 _RL var3Dv(1-OLx:sNx+OLx,1-OLy:sNy+OLy,Nr,nSx,nSy)
59 _RS dumRS(1)
60 _RL dumRL(1)
61
62 IF ( DIFFERENT_MULTIPLE(adjmonitorFreq,myTime,deltaTClock) ) THEN
63
64 IF ( MASTER_CPU_IO(myThid) ) THEN
65 C-- only the master thread is allowed to switch On/Off mon_write_stdout
66 C & mon_write_mnc (since it is the only thread that uses those flags):
67
68 IF (monitor_stdio) THEN
69 mon_write_stdout = .TRUE.
70 ELSE
71 mon_write_stdout = .FALSE.
72 ENDIF
73 mon_write_mnc = .FALSE.
74 #ifdef ALLOW_MNC
75 IF (useMNC .AND. monitor_mnc) THEN
76 DO k = 1,MAX_LEN_MBUF
77 mon_fname(k:k) = ' '
78 ENDDO
79 mon_fname(1:9) = 'admonitor'
80 CALL MNC_CW_APPEND_VNAME(
81 & 'T', '-_-_--__-__t', 0,0, myThid)
82 CALL MNC_CW_SET_UDIM(mon_fname, -1, myThid)
83 CALL MNC_CW_RL_W_S(
84 & 'D',mon_fname,1,1,'T', myTime, myThid)
85 CALL MNC_CW_SET_UDIM(mon_fname, 0, myThid)
86 mon_write_mnc = .TRUE.
87 ENDIF
88 #endif /* ALLOW_MNC */
89
90 C Dynamics field monitor start
91 IF ( mon_write_stdout ) THEN
92 WRITE(msgBuf,'(2A)') '// ==========================',
93 & '============================='
94 CALL PRINT_MESSAGE( msgBuf, mon_ioUnit, SQUEEZE_RIGHT , 1)
95 WRITE(msgBuf,'(A)')
96 & '// Begin MONITOR dynamic field statistics'
97 CALL PRINT_MESSAGE( msgBuf, mon_ioUnit, SQUEEZE_RIGHT , 1)
98 WRITE(msgBuf,'(2A)') '// ==========================',
99 & '============================='
100 CALL PRINT_MESSAGE( msgBuf, mon_ioUnit, SQUEEZE_RIGHT , 1)
101 ENDIF
102
103 C-- endif master cpu io
104 ENDIF
105
106 C Print the time to make grepping the stdout easier
107 CALL MON_SET_PREF('ad_time',myThid)
108 CALL MON_OUT_I( '_tsnumber', myIter,mon_string_none,myThid)
109 CALL MON_OUT_RL('_secondsf', myTime,mon_string_none,myThid)
110
111 C Print the basic statistics of model state variables
112 CALL MON_SET_PREF('ad_dynstat',myThid)
113 IF ( mon_AdVarExch.EQ.1 ) THEN
114 #ifndef AUTODIFF_TAMC_COMPATIBILITY
115 CALL ADEXCH_3D_RL( adEtaN, 1 , myThid )
116 CALL ADEXCH_UV_3D_RL( aduVel, advVel, .TRUE., Nr, myThid )
117 CALL ADEXCH_3D_RL( adwVel, Nr, myThid )
118 CALL ADEXCH_3D_RL( adTheta, Nr, myThid )
119 CALL ADEXCH_3D_RL( adSalt, Nr, myThid )
120 #endif
121 ENDIF
122 IF ( mon_AdVarExch.NE.2 ) THEN
123 CALL MON_WRITESTATS_RL( 1, adEtaN, '_adeta',
124 & maskInC, maskInC, rA , drF, dummyRL, myThid )
125 CALL MON_WRITESTATS_RL( Nr, aduVel, '_aduvel',
126 & hFacW, maskInW, rAw, drF, dummyRL, myThid )
127 CALL MON_WRITESTATS_RL( Nr, advVel, '_advvel',
128 & hFacS, maskInS, rAs, drF, dummyRL, myThid )
129 CALL MON_WRITESTATS_RL( Nr, adwVel, '_adwvel',
130 & maskC, maskInC, rA , drC, dummyRL, myThid )
131 CALL MON_WRITESTATS_RL( Nr, adTheta,'_adtheta',
132 & hFacC, maskInC, rA , drF, dummyRL, myThid )
133 CALL MON_WRITESTATS_RL( Nr, adSalt, '_adsalt',
134 & hFacC, maskInC, rA , drF, dummyRL, myThid )
135 IF ( monitorSelect.GE.3 .AND.
136 & nSx.EQ.1 .AND. nSy.EQ.1 ) THEN
137 C- print stats only if nSx=nSy=1 since otherwise stats are wrong
138 k = 1
139 IF ( usingPCoords ) k = Nr
140 CALL MON_WRITESTATS_RL( 1, adTheta(1-OLx,1-OLy,k,1,1),
141 & '_adsst', maskInC, maskInC, rA, drF, dummyRL, myThid )
142 CALL MON_WRITESTATS_RL( 1, adSalt(1-OLx,1-OLy,k,1,1),
143 & '_adsss', maskInC, maskInC, rA, drF, dummyRL, myThid )
144 ENDIF
145 ELSE
146 C case dumpAdVarExch = 2
147 CALL COPY_ADVAR_OUTP( dumRS, adEtaN, var2Du, 1 , 12, myThid )
148 CALL MON_WRITESTATS_RL( 1, var2Du, '_adeta',
149 & maskInC, maskInC, rA , drF, dummyRL, myThid )
150
151 CALL COPY_AD_UV_OUTP( dumRS, dumRS, aduVel, advVel,
152 & var3Du, var3Dv, Nr, 34, myThid )
153 CALL MON_WRITESTATS_RL( Nr, var3Du, '_aduvel',
154 & hFacW, maskInW, rAw, drF, dummyRL, myThid )
155 CALL MON_WRITESTATS_RL( Nr, var3Dv, '_advvel',
156 & hFacS, maskInS, rAs, drF, dummyRL, myThid )
157
158 CALL COPY_ADVAR_OUTP( dumRS, adwVel, var3Du, Nr, 12, myThid )
159 CALL MON_WRITESTATS_RL( Nr, var3Du, '_adwvel',
160 & maskC, maskInC, rA , drC, dummyRL, myThid )
161 CALL COPY_ADVAR_OUTP( dumRS, adTheta,var3Du, Nr, 12, myThid )
162 CALL COPY_ADVAR_OUTP( dumRS, adSalt, var3Dv, Nr, 12, myThid )
163 CALL MON_WRITESTATS_RL( Nr, var3Du, '_adtheta',
164 & hFacC, maskInC, rA , drF, dummyRL, myThid )
165 CALL MON_WRITESTATS_RL( Nr, var3Dv, '_adsalt',
166 & hFacC, maskInC, rA , drF, dummyRL, myThid )
167 IF ( monitorSelect.GE.3 .AND.
168 & nSx.EQ.1 .AND. nSy.EQ.1 ) THEN
169 C- print stats only if nSx=nSy=1 since otherwise stats are wrong
170 k = 1
171 IF ( usingPCoords ) k = Nr
172 CALL MON_WRITESTATS_RL( 1, var3Du(1-OLx,1-OLy,k,1,1),
173 & '_adsst', maskInC, maskInC, rA, drF, dummyRL, myThid )
174 CALL MON_WRITESTATS_RL( 1, var3Dv(1-OLx,1-OLy,k,1,1),
175 & '_adsss', maskInC, maskInC, rA, drF, dummyRL, myThid )
176 ENDIF
177 ENDIF
178
179 C Print the basic statistics of external forcing
180 IF ( monitorSelect.GE.3 ) THEN
181 CALL MON_SET_PREF('ad_forcing',myThid)
182 IF ( mon_AdVarExch.NE.2 ) THEN
183 CALL MON_WRITESTATS_RS( 1, adQnet, '_adqnet',
184 & maskInC, maskInC, rA , drF, dummyRL, myThid )
185 #ifdef SHORTWAVE_HEATING
186 CALL MON_WRITESTATS_RS( 1, adQsw , '_adqsw',
187 & maskInC, maskInC, rA , drF, dummyRL, myThid )
188 #endif
189 CALL MON_WRITESTATS_RS( 1, adEmPmR,'_adempmr',
190 & maskInC, maskInC, rA , drF, dummyRL, myThid )
191 CALL MON_WRITESTATS_RS( 1, adfu , '_adfu',
192 & maskInW, maskInW, rAw, drF, dummyRL, myThid )
193 CALL MON_WRITESTATS_RS( 1, adfv , '_adfv',
194 & maskInS, maskInS, rAs, drF, dummyRL, myThid )
195 ELSE
196 C case dumpAdVarExch = 2
197 CALL COPY_ADVAR_OUTP( adQnet, dumRL, var2Du, 1, 11, myThid )
198 CALL MON_WRITESTATS_RL( 1, var2Du, '_adqnet',
199 & maskInC, maskInC, rA , drF, dummyRL, myThid )
200 #ifdef SHORTWAVE_HEATING
201 CALL COPY_ADVAR_OUTP( adQsw, dumRL, var2Du, 1, 11, myThid )
202 CALL MON_WRITESTATS_RL( 1, var2Du, '_adqsw',
203 & maskInC, maskInC, rA , drF, dummyRL, myThid )
204 #endif
205 CALL COPY_ADVAR_OUTP( adEmPmR,dumRL, var2Du, 1, 11, myThid )
206 CALL MON_WRITESTATS_RL( 1, var2Du, '_adempmr',
207 & maskInC, maskInC, rA , drF, dummyRL, myThid )
208 CALL COPY_AD_UV_OUTP( adFu, adFv, dumRL, dumRL,
209 & var2Du, var2Dv, 1, 33, myThid )
210 CALL MON_WRITESTATS_RL( 1, var2Du, '_adfu',
211 & maskInW, maskInW, rAw, drF, dummyRL, myThid )
212 CALL MON_WRITESTATS_RL( 1, var2Dv, '_adfv',
213 & maskInS, maskInS, rAs, drF, dummyRL, myThid )
214 ENDIF
215 ENDIF
216
217 C Dynamics field monitor finish
218 IF ( MASTER_CPU_IO(myThid) ) THEN
219 C-- only the master thread is allowed to switch On/Off mon_write_stdout
220 C & mon_write_mnc (since it is the only thread that uses those flags):
221
222 IF ( mon_write_stdout ) THEN
223 WRITE(msgBuf,'(2A)') '// ==========================',
224 & '============================='
225 CALL PRINT_MESSAGE( msgBuf, mon_ioUnit, SQUEEZE_RIGHT , 1)
226 WRITE(msgBuf,'(A)')
227 & '// End MONITOR dynamic field statistics'
228 CALL PRINT_MESSAGE( msgBuf, mon_ioUnit, SQUEEZE_RIGHT , 1)
229 WRITE(msgBuf,'(2A)') '// ==========================',
230 & '============================='
231 CALL PRINT_MESSAGE( msgBuf, mon_ioUnit, SQUEEZE_RIGHT , 1)
232 ENDIF
233
234 mon_write_stdout = .FALSE.
235 mon_write_mnc = .FALSE.
236
237 C-- endif master cpu io
238 ENDIF
239
240 C endif different multiple
241 ENDIF
242
243 #ifdef ALLOW_EXF
244 cph This case is handled separately in exf_adjoint_snapshots_ad.F
245 #endif
246
247 #ifdef ALLOW_SEAICE
248 CALL ADSEAICE_MONITOR ( myTime, myIter, myThid )
249 #endif
250
251 #ifdef ALLOW_PTRACERS
252 CALL ADPTRACERS_MONITOR ( myTime, myIter, myThid )
253 #endif
254
255 #endif /* ALLOW_AUTODIFF_MONITOR */
256 #endif /* ALLOW_ADJOINT_RUN */
257
258 RETURN
259 END

  ViewVC Help