/[MITgcm]/MITgcm/pkg/mnc/mnc_cw_readwrite.template
ViewVC logotype

Diff of /MITgcm/pkg/mnc/mnc_cw_readwrite.template

Parent Directory Parent Directory | Revision Log Revision Log | View Revision Graph Revision Graph | View Patch Patch

revision 1.1 by edhill, Sat Jan 31 04:13:09 2004 UTC revision 1.22 by edhill, Wed Oct 20 21:26:14 2004 UTC
# Line 4  C $Name$ Line 4  C $Name$
4  #include "MNC_OPTIONS.h"  #include "MNC_OPTIONS.h"
5                
6  C---+----1----+----2----+----3----+----4----+----5----+----6----+----7-|--+----|  C---+----1----+----2----+----3----+----4----+----5----+----6----+----7-|--+----|
7    CBOP 0
8    C !ROUTINE: MNC_CW_RX_W_S
9    
10        SUBROUTINE MNC_CW_RX_WRITES_YY(  C !INTERFACE:
11       I     myThid,        SUBROUTINE MNC_CW_RX_W_S(
12         I     stype,
13       I     fbname, bi,bj,       I     fbname, bi,bj,
14       I     vtype,       I     vtype,
15       I     indu,       I     var,
16       I     var )       I     myThid )
17    
18    C     !DESCRIPTION:
19    C     A scalar version of MNC_CW_RX_W() for compilers that cannot
20    C     gracefully handle the conversion on their own.
21          
22    C     !USES:
23          implicit none
24    
25    C     !INPUT PARAMETERS:
26          integer myThid, bi,bj
27          character*(*) stype, fbname, vtype
28          __V var
29          __V var_arr(1)
30    CEOP
31    
32          var_arr(1) = var
33          CALL MNC_CW_RX_W(stype,fbname,bi,bj,vtype, var_arr, myThid)
34    
35          RETURN
36          END
37    
38    C---+----1----+----2----+----3----+----4----+----5----+----6----+----7-|--+----|
39    CBOP 0
40    C !ROUTINE: MNC_CW_RX_W
41    
42    C !INTERFACE:
43          SUBROUTINE MNC_CW_RX_W(
44         I     stype,
45         I     fbname, bi,bj,
46         I     vtype,
47         I     var,
48         I     myThid )
49    
50    C     !DESCRIPTION:
51    C     A scalar version of MNC_CW_RX_W() for compilers that cannot
52    C     gracefully handle the conversion on their own.
53          
54    C     !USES:
55        implicit none        implicit none
56    
57    C     !INPUT PARAMETERS:
58          integer myThid, bi,bj
59          character*(*) stype, fbname, vtype
60          __V var(*)
61          INTEGER offsets(9)
62    CEOP
63          INTEGER i
64    
65          DO i = 1,9
66            offsets(i) = 0
67          ENDDO
68          CALL MNC_CW_RX_W_OFFSET(stype,fbname,bi,bj,vtype, var,
69         &     offsets, myThid)
70    
71          RETURN
72          END
73    
74    C---+----1----+----2----+----3----+----4----+----5----+----6----+----7-|--+----|
75    CBOP 0
76    C !ROUTINE: MNC_CW_RX_W_OFFSET
77    
78    C !INTERFACE:
79          SUBROUTINE MNC_CW_RX_W_OFFSET(
80         I     stype,
81         I     fbname, bi,bj,
82         I     vtype,
83         I     var,
84         I     offsets,
85         I     myThid )
86    
87    C     !DESCRIPTION:
88    C     This subroutine writes one variable to a file or a file group,
89    C     depending upon the tile indicies.
90          
91    C     !USES:
92          implicit none
93  #include "netcdf.inc"  #include "netcdf.inc"
94  #include "mnc_common.h"  #include "mnc_common.h"
95    #include "SIZE.h"
96  #include "EEPARAMS.h"  #include "EEPARAMS.h"
 #include "EESUPPORT.h"  
97  #include "PARAMS.h"  #include "PARAMS.h"
98  #include "GRID.h"  #include "MNC_PARAMS.h"
99    
100  C     Arguments  C     !INPUT PARAMETERS:
101        integer myThid, bi,bj, indu        integer myThid, bi,bj
102        character*(*) fbname, vtype        character*(*) stype, fbname, vtype
103        _RX var(*)        __V var(*)
104          INTEGER offsets(*)
105    CEOP
106    
107    C     !LOCAL VARIABLES:
108          integer i,j,k, indv,nvf,nvl, n1,n2, igrid, ntot, indu
109          integer bis,bie, bjs,bje, uniq_tnum, nfname, iseq
110          integer fid, idv, indvids, ndim, indf, err
111          integer lbi,lbj, bidim,bjdim, unlim_sz, kr
112          integer p(9),s(9),e(9), dimnc(9)
113          integer vstart(9),vcount(9), udo(9)
114          integer j1,j2,j3,j4,j5,j6,j7, k1,k2,k3,k4,k5,k6,k7
115          integer indfg, fg1,fg2, npath
116          character*(MAX_LEN_MBUF) msgbuf
117          character*(MNC_MAX_CHAR) fname
118          character*(MNC_MAX_CHAR) path_fname
119          REAL*8  resh_d( sNx + 2*OLx + sNy + 2*OLy )
120          REAL*4  resh_r( sNx + 2*OLx + sNy + 2*OLy )
121          INTEGER resh_i( sNx + 2*OLx + sNy + 2*OLy )
122    
123  C     Functions  C     Functions
124        integer IFNBLNK, ILNBLNK        integer IFNBLNK, ILNBLNK
125    
126  C     Local Variables  C     Only do I/O if I am the master thread
127        integer i, indv,nvf,nvl, n1,n2        _BEGIN_MASTER( myThid )
128        integer bis,bie, bjs,bje, iG,jG, uniq_tnum  
129        integer tile_num  C     Get the current index for the unlimited dimension from the file
130    C     group (or base) name
131          fg1 = IFNBLNK(fbname)
132          fg2 = ILNBLNK(fbname)
133          CALL MNC_GET_IND(MNC_MAX_ID, fbname, mnc_cw_fgnm, indfg, myThid)
134          IF (indfg .LT. 1) THEN
135            write(msgbuf,'(3a)')
136         &       'MNC_CW_RX_W ERROR: file group name ''',
137         &       fbname(fg1:fg2), ''' is not defined'
138            CALL print_error(msgbuf, mythid)
139            STOP 'ABNORMAL END: S/R MNC_CW_RX_W'
140          ENDIF
141          indu = mnc_cw_fgud(indfg)
142          iseq = mnc_cw_fgis(indfg)
143    
144    C     Check that the Variable Type exists
145          nvf = IFNBLNK(vtype)
146          nvl = ILNBLNK(vtype)
147          CALL MNC_GET_IND(MNC_MAX_ID, vtype, mnc_cw_vname, indv, myThid)
148          IF (indv .LT. 1) THEN
149            write(msgbuf,'(3a)') 'MNC_CW_RX_W ERROR: vtype ''',
150         &       vtype(nvf:nvl), ''' is not defined'
151            CALL print_error(msgbuf, mythid)
152            STOP 'ABNORMAL END: S/R MNC_CW_RX_W'
153          ENDIF
154          igrid = mnc_cw_vgind(indv)
155    
156    C     Set the bi,bj indicies
157          bis = bi
158          bie = bi
159          IF (bi .LT. 1) THEN
160            bis = 1
161            bie = nSx
162          ENDIF
163          bjs = bj
164          bje = bj
165          IF (bj .LT. 1) THEN
166            bjs = 1
167            bje = nSy
168          ENDIF
169    
170          DO lbj = bjs,bje
171            DO lbi = bis,bie
172    
173    C         Create the file name
174              CALL MNC_CW_GET_TILE_NUM(lbi,lbj, uniq_tnum, myThid)
175              fname(1:MNC_MAX_CHAR) = mnc_blank_name(1:MNC_MAX_CHAR)
176              n1 = IFNBLNK(fbname)
177              n2 = ILNBLNK(fbname)
178              ntot = n2 - n1 + 1
179              fname(1:ntot) = fbname(n1:n2)
180              ntot = ntot + 1
181              fname(ntot:ntot) = '.'
182              write(fname((ntot+1):(ntot+14)),'(i4.4,a1,i6.6,a3)')
183         &         iseq,'.',uniq_tnum, '.nc'
184              nfname = ntot + 14
185    
186    C         Add the path to the file name
187              IF (mnc_use_outdir) THEN
188                path_fname(1:MNC_MAX_CHAR) = mnc_blank_name(1:MNC_MAX_CHAR)
189                npath = ILNBLNK(mnc_out_path)
190                path_fname(1:npath) = mnc_out_path(1:npath)
191                path_fname((npath+1):(npath+nfname)) = fname(1:nfname)
192                fname(1:MNC_MAX_CHAR) = path_fname(1:MNC_MAX_CHAR)
193                nfname = npath + nfname
194              ENDIF
195    
196    C         Append to an existing or create a new file
197              CALL MNC_CW_FILE_AORC(fname, indf, myThid)
198              fid = mnc_f_info(indf,2)
199    
200    C         Ensure that all the NetCDF dimensions are defined and create a
201    C         local copy of them
202              DO i = 1,9
203                dimnc(i) = 1
204              ENDDO
205              DO i = 1,mnc_cw_ndim(igrid)
206                IF (mnc_cw_dims(i,igrid) .EQ. -1) THEN
207                  dimnc(i) = -1
208                ELSE
209                  dimnc(i) = mnc_cw_ie(i,igrid) - mnc_cw_is(i,igrid) + 1
210                ENDIF
211                CALL MNC_DIM_INIT(fname,
212         &           mnc_cw_dn(i,igrid), dimnc(i), myThid)
213              ENDDO
214    
215    C         Ensure that the "grid" is defined
216              CALL MNC_GRID_INIT(fname, mnc_cw_gname(igrid),
217         &        mnc_cw_ndim(igrid), mnc_cw_dn(1,igrid), myThid)
218    
219    C         Ensure that the variable is defined
220              IF (stype(1:1) .EQ. 'D')
221         &         CALL MNC_VAR_INIT_DBL(
222         &         fname, mnc_cw_gname(igrid), vtype, myThid)
223              IF (stype(1:1) .EQ. 'R')
224         &         CALL MNC_VAR_INIT_REAL(
225         &         fname, mnc_cw_gname(igrid), vtype, myThid)
226              IF (stype(1:1) .EQ. 'I')
227         &         CALL MNC_VAR_INIT_INT(
228         &         fname, mnc_cw_gname(igrid), vtype, myThid)
229    
230              DO i = 1,mnc_fv_ids(indf,1)
231                j = 2 + 3*(i - 1)
232                IF (mnc_v_names(mnc_fv_ids(indf,j)) .EQ. vtype) THEN
233                  idv = mnc_fv_ids(indf,j+1)
234                  indvids = mnc_fd_ind(indf, mnc_f_info(indf,
235         &             (mnc_fv_ids(indf,j+2) + 1)) )
236                  GOTO 10
237                ENDIF
238              ENDDO
239              write(msgbuf,'(4a)') 'MNC_MNC_CW_RX_W ERROR: ',
240         &         'cannot reference variable ''', vtype, ''''
241              CALL print_error(msgbuf, mythid)
242              STOP 'ABNORMAL END: package MNC'
243     10       CONTINUE
244    
245    C         Check for bi,bj indicies
246              bidim = mnc_cw_vbij(1,indv)
247              bjdim = mnc_cw_vbij(2,indv)
248    CEH3      write(*,*) 'bidim,bjdim = ', bidim,bjdim
249    
250    C         Set the dimensions for the in-memory array
251              ndim = mnc_cw_ndim(igrid)
252              k = mnc_cw_dims(1,igrid)
253              IF (k .GT. 0) THEN
254                p(1) = k
255              ELSE
256                p(1) = 1
257              ENDIF
258              DO i = 2,9
259                k = mnc_cw_dims(i,igrid)
260                IF (k .LT. 1) THEN
261                  k = 1
262                ENDIF
263                IF ((bidim .GT. 0) .AND. (i .EQ. bidim)) THEN
264                  p(i) = nSx * p(i-1)
265                ELSEIF ((bjdim .GT. 0) .AND. (i .EQ. bjdim)) THEN
266                  p(i) = nSy * p(i-1)
267                ELSE
268                  p(i) = k * p(i-1)
269                ENDIF
270                IF (offsets(i) .GT. 0) THEN
271                  k = 1
272                  p(i) = k * p(i-1)
273                ENDIF
274              ENDDO
275    
276    C         Set starting and ending indicies for the in-memory array and
277    C         the unlimited dimension offset for the NetCDF array
278              DO i = 1,9
279                udo(i) = 0
280                s(i) = 1
281                e(i) = 1
282                IF (i .LE. ndim) THEN
283                  s(i) = mnc_cw_is(i,igrid)
284                  e(i) = mnc_cw_ie(i,igrid)
285                ENDIF
286    C           Check for the unlimited dimension
287                IF ((i .EQ. ndim)
288         &           .AND. (mnc_cw_dims(i,igrid) .EQ. -1)) THEN
289                  IF (indu .GT. 0) THEN
290    C               Use the indu value
291                    udo(i) = indu - 1
292                  ELSEIF (indu .EQ. -1) THEN
293    C               Append one to the current unlimited dim size
294                    CALL MNC_DIM_UNLIM_SIZE( fname, unlim_sz, myThid)
295                    udo(i) = unlim_sz
296                  ELSE
297    C               Use the current unlimited dim size
298                    CALL MNC_DIM_UNLIM_SIZE( fname, unlim_sz, myThid)
299                    udo(i) = unlim_sz - 1
300                  ENDIF
301                ENDIF
302              ENDDO
303              IF (bidim .GT. 0) THEN
304                s(bidim) = lbi
305                e(bidim) = lbi
306              ENDIF
307              IF (bjdim .GT. 0) THEN
308                s(bjdim) = lbj
309                e(bjdim) = lbj
310              ENDIF
311              
312    C         Check the offsets
313              DO i = 1,9
314                IF (offsets(i) .GT. 0) THEN
315                  udo(i) = udo(i) + offsets(i) - 1
316                  s(i) = 1
317                  e(i) = 1
318                ENDIF
319              ENDDO
320    
321    C         Add the global attributes
322              CALL MNC_CW_SET_GATTR( fname, lbi,lbj, uniq_tnum, myThid)
323    
324    C         Add the per-variable attributes
325              DO i = 1,mnc_cw_vnat(1,indv)
326                CALL MNC_VAR_ADD_ATTR_STR( fname, vtype,
327         &           mnc_cw_vtnm(i,indv), mnc_cw_vtat(i,indv), myThid)
328              ENDDO
329              DO i = 1,mnc_cw_vnat(2,indv)
330                CALL MNC_VAR_ADD_ATTR_INT( fname, vtype,
331         &           mnc_cw_vinm(i,indv), 1, mnc_cw_viat(i,indv), myThid)
332              ENDDO
333              DO i = 1,mnc_cw_vnat(3,indv)
334                CALL MNC_VAR_ADD_ATTR_DBL( fname, vtype,
335         &           mnc_cw_vdnm(i,indv), 1, mnc_cw_vdat(i,indv), myThid)
336              ENDDO
337    
338              CALL MNC_FILE_ENDDEF(fname, myThid)
339    
340              write(msgbuf,'(5a)') 'writing variable type ''',
341         &         vtype(nvf:nvl), ''' within file ''',
342         &         fname(1:nfname), ''''
343    
344    C         DO i = 1,9
345    C         write(*,*) 'i,p(i),s(i),e(i),udo(i),offsets(i) = ',
346    C         &        i,p(i),s(i),e(i),udo(i),offsets(i)
347    C         ENDDO
348    
349    C         Write the variable one vector at a time
350              DO j7 = s(7),e(7)
351                k7 = (j7 - 1)*p(6)
352                vstart(7) = udo(7) + j7 - s(7) + 1
353                vcount(7) = 1
354                DO j6 = s(6),e(6)
355                  k6 = (j6 - 1)*p(5) + k7
356                  vstart(6) = udo(6) + j6 - s(6) + 1
357                  vcount(6) = 1
358                  DO j5 = s(5),e(5)
359                    k5 = (j5 - 1)*p(4) + k6
360                    vstart(5) = udo(5) + j5 - s(5) + 1
361                    vcount(5) = 1
362                    DO j4 = s(4),e(4)
363                      k4 = (j4 - 1)*p(3) + k5
364                      vstart(4) = udo(4) + j4 - s(4) + 1
365                      vcount(4) = 1
366                      DO j3 = s(3),e(3)
367                        k3 = (j3 - 1)*p(2) + k4
368                        vstart(3) = udo(3) + j3 - s(3) + 1
369                        vcount(3) = 1
370                        DO j2 = s(2),e(2)
371                          k2 = (j2 - 1)*p(1) + k3
372                          vstart(2) = udo(2) + j2 - s(2) + 1
373                          vcount(2) = 1
374    
375          kr = 0
376          vstart(1) = udo(1) + 1
377          vcount(1) = e(1) - s(1) + 1
378    
379          IF (stype(1:1) .EQ. 'D') THEN
380            DO j1 = s(1),e(1)
381              k1 = k2 + j1
382              kr = kr + 1
383              resh_d(kr) = var(k1)
384            ENDDO
385            err = NF_PUT_VARA_DOUBLE(fid, idv, vstart, vcount, resh_d)
386          ENDIF
387          IF (stype(1:1) .EQ. 'R') THEN
388            DO j1 = s(1),e(1)
389              k1 = k2 + j1
390              kr = kr + 1
391              resh_r(kr) = var(k1)
392            ENDDO
393            err = NF_PUT_VARA_REAL(fid, idv, vstart, vcount, resh_r)
394          ENDIF
395          IF (stype(1:1) .EQ. 'I') THEN
396            DO j1 = s(1),e(1)
397              k1 = k2 + j1
398              kr = kr + 1
399              resh_i(kr) = var(k1)
400            ENDDO
401            err = NF_PUT_VARA_INT(fid, idv, vstart, vcount, resh_i)
402          ENDIF
403    
404          CALL MNC_HANDLE_ERR(err, msgbuf, myThid)
405    
406                        ENDDO
407                      ENDDO
408                    ENDDO
409                  ENDDO
410                ENDDO
411              ENDDO
412    
413    C         Sync the file
414              err = NF_SYNC(fid)
415              write(msgbuf,'(3a)') 'sync for file ''', fname,
416         &         ''' in S/R MNC_CW_RX_W'
417              CALL MNC_HANDLE_ERR(err, msgbuf, myThid)
418    
419            ENDDO
420          ENDDO
421    
422          _END_MASTER( myThid )
423    
424          RETURN
425          END
426          
427    
428    C---+----1----+----2----+----3----+----4----+----5----+----6----+----7-|--+----|
429    CBOP 0
430    C !ROUTINE: MNC_CW_RX_R_S
431    
432    C !INTERFACE:
433          SUBROUTINE MNC_CW_RX_R_S(
434         I     stype,
435         I     fbname, bi,bj,
436         I     vtype,
437         I     var,
438         I     myThid )
439    
440    C     !DESCRIPTION:
441    C     A scalar version of MNC_CW_RX_R() for compilers that cannot
442    C     gracefully handle the conversion on their own.
443          
444    C     !USES:
445          implicit none
446    
447    C     !INPUT PARAMETERS:
448          integer myThid, bi,bj
449          character*(*) stype, fbname, vtype
450          __V var
451          __V var_arr(1)
452    CEOP
453          var_arr(1) = var
454    
455          CALL MNC_CW_RX_R(stype,fbname,bi,bj,vtype, var_arr, myThid)
456    
457          RETURN
458          END
459    
460    
461    C---+----1----+----2----+----3----+----4----+----5----+----6----+----7-|--+----|
462    CBOP 0
463    C !ROUTINE: MNC_CW_RX_R
464    
465    C !INTERFACE:
466          SUBROUTINE MNC_CW_RX_R(
467         I     stype,
468         I     fbname, bi,bj,
469         I     vtype,
470         I     var,
471         I     myThid )
472    
473    C     !DESCRIPTION:
474    C     This subroutine reads one variable from a file or a file group,
475    C     depending upon the tile indicies.
476          
477    C     !USES:
478          implicit none
479    #include "netcdf.inc"
480    #include "mnc_common.h"
481    #include "SIZE.h"
482    #include "EEPARAMS.h"
483    #include "PARAMS.h"
484    #include "MNC_PARAMS.h"
485    
486    C     !INPUT PARAMETERS:
487          integer myThid, bi,bj
488          character*(*) stype, fbname, vtype
489          __V var(*)
490    CEOP
491    
492    C     !LOCAL VARIABLES:
493          integer i,k, nvf,nvl, n1,n2, igrid, ntot, indu
494          integer bis,bie, bjs,bje, uniq_tnum, nfname, fid, idv
495          integer ndim, indf, err, lbi,lbj, bidim,bjdim, unlim_sz, kr
496          integer ind_fv_ids, ind_vt, ierr, atype, alen
497          integer f_sNx,f_sNy, npath
498          integer p(9),s(9),e(9), vstart(9),vcount(9), udo(9)
499          integer j1,j2,j3,j4,j5,j6,j7, k1,k2,k3,k4,k5,k6,k7
500        character*(MAX_LEN_MBUF) msgbuf        character*(MAX_LEN_MBUF) msgbuf
501        character*(MNC_MAX_CHAR) fname        character*(MNC_MAX_CHAR) fname
502          character*(MNC_MAX_CHAR) path_fname
503          integer indfg, fg1,fg2
504          REAL*8  resh_d( sNx + 2*OLx + sNy + 2*OLy )
505          REAL*4  resh_r( sNx + 2*OLx + sNy + 2*OLy )
506          INTEGER resh_i( sNx + 2*OLx + sNy + 2*OLy )
507    
508  C     Temporary storage for the simultaneous type conversion and  C     Functions
509  C     re-shaping before passing to NetCDF        integer IFNBLNK, ILNBLNK
 #define mnc_rtype_YY  
 #ifdef  mnc_rtype_D  
       REAL*8 resh( sNx + 2*OLx + sNy + 2*OLy )  
 #endif  
 #ifdef  mnc_rtype_R  
       REAL*4 resh( sNx + 2*OLx + sNy + 2*OLy )  
 #endif  
 #undef mnc_rtype_YY  
510    
511  C     Only do I/O if I am the master thread  C     Only do I/O if I am the master thread
512        _BEGIN_MASTER( myThid )        _BEGIN_MASTER( myThid )
513    
514    C     Get the current index for the unlimited dimension from the file
515    C     group (or base) name
516          fg1 = IFNBLNK(fbname)
517          fg2 = ILNBLNK(fbname)
518          CALL MNC_GET_IND(MNC_MAX_ID, fbname, mnc_cw_fgnm, indfg, myThid)
519          IF (indfg .LT. 1) THEN
520            write(msgbuf,'(3a)')
521         &       'MNC_CW_RX_W ERROR: file group name ''',
522         &       fbname(fg1:fg2), ''' is not defined'
523            CALL print_error(msgbuf, mythid)
524            STOP 'ABNORMAL END: S/R MNC_CW_RX_W'
525          ENDIF
526          indu = mnc_cw_fgud(indfg)
527    
528  C     Check that the Variable Type exists  C     Check that the Variable Type exists
529        nvf = IFNBLNK(vtype)        nvf = IFNBLNK(vtype)
530        nvl = ILNBLNK(vtype)        nvl = ILNBLNK(vtype)
531        CALL MNC_GET_IND(myThid, MNC_MAX_ID, vtype, mnc_cw_vname, indv)        CALL MNC_GET_IND( MNC_MAX_ID, vtype, mnc_cw_vname, ind_vt, myThid)
532        IF (indg .LT. 1) THEN        IF (ind_vt .LT. 1) THEN
533          write(msgbuf,'(3a)') 'MNC_CW_RX_WRITES_YY ERROR: vtype ''',          write(msgbuf,'(3a)') 'MNC_CW_RX_R ERROR: vtype ''',
534       &       vtype(nff:nfl), ''' is not defined'       &       vtype(nvf:nvl), ''' is not defined'
535          CALL print_error(msgbuf, mythid)          CALL print_error(msgbuf, mythid)
536          stop 'ABNORMAL END: S/R MNC_CW_RX_WRITES_YY'          STOP 'ABNORMAL END: S/R MNC_CW_RX_R'
537        ENDIF        ENDIF
538          igrid = mnc_cw_vgind(ind_vt)
539    
540    C     Check for bi,bj indicies
541          bidim = mnc_cw_vbij(1,ind_vt)
542          bjdim = mnc_cw_vbij(2,ind_vt)
543    
544    C     Set the bi,bj indicies
545          bis = bi
546          bie = bi
547        IF (bi .LT. 1) THEN        IF (bi .LT. 1) THEN
548          bis = 1          bis = 1
549          bie = nSx          bie = nSx
       ELSE  
         bis = bi  
         bie = bi  
550        ENDIF        ENDIF
551          bjs = bj
552          bje = bj
553        IF (bj .LT. 1) THEN        IF (bj .LT. 1) THEN
554          bjs = 1          bjs = 1
555          bje = nSy          bje = nSy
       ELSE  
         bjs = bj  
         bje = bj  
556        ENDIF        ENDIF
557    
558        DO bj = bjs,bje        DO lbj = bjs,bje
559          DO bi = bis,bie          DO lbi = bis,bie
560    
561  C         Create the file name  C         Create the file name
562            CALL MNC_CW_GET_TILE_NUM(myThid, bi,bj, uniq_tnum)            CALL MNC_CW_GET_TILE_NUM( lbi,lbj, uniq_tnum, myThid)
563            fname(1:MNC_MAX_CHAR) = mnc_blank_name(1:MNC_MAX_CHAR)            fname(1:MNC_MAX_CHAR) = mnc_blank_name(1:MNC_MAX_CHAR)
564            n1 = IFNBLNK(fbname)            n1 = IFNBLNK(fbname)
565            n2 = ILNBLNK(fbname)            n2 = ILNBLNK(fbname)
# Line 89  C         Create the file name Line 568  C         Create the file name
568            ntot = ntot + 1            ntot = ntot + 1
569            fname(ntot:ntot) = '.'            fname(ntot:ntot) = '.'
570            write(fname((ntot+1):(ntot+9)),'(i6.6,a3)') uniq_tnum, '.nc'            write(fname((ntot+1):(ntot+9)),'(i6.6,a3)') uniq_tnum, '.nc'
571              nfname = ntot+9
572    
573  C         Append to existing or create new file  C         Add the path to the file name
574            CALL MNC_CW_FILE_AORC(myThid, fname)            IF (mnc_use_indir) THEN
575                path_fname(1:MNC_MAX_CHAR) = mnc_blank_name(1:MNC_MAX_CHAR)
576                npath = ILNBLNK(mnc_indir_str)
577                path_fname(1:npath) = mnc_indir_str(1:npath)
578                path_fname((npath+1):(npath+nfname)) = fname(1:nfname)
579                fname(1:MNC_MAX_CHAR) = path_fname(1:MNC_MAX_CHAR)
580                nfname = npath + nfname
581              ENDIF
582    
583    C         Open the existing file
584              CALL MNC_FILE_TRY_READ( fname, ierr, indf, myThid)
585    
586    C         Check that the variable (VType) is defined within the file
587              CALL MNC_GET_FVINDS( fname, vtype, indf, ind_fv_ids, myThid)
588              IF ((indf .LT. 1) .OR. (ind_fv_ids .LT. 1)) THEN
589                write(msgbuf,'(4a)') 'MNC_CW_RX_R ERROR: vtype ''',
590         &           vtype(nvf:nvl), ''' is not defined within file ''',
591         &           fname(1:nfname)
592                CALL print_error(msgbuf, mythid)
593                STOP 'ABNORMAL END: S/R MNC_CW_RX_R'
594              ENDIF
595              fid = mnc_f_info(indf,2)
596              idv = mnc_fv_ids(indf,ind_fv_ids+1)
597    
598    C         Check that the current sNy,sNy values and the in-file values
599    C         are compatible and WARN (only warn) if not
600              f_sNx = -1
601              f_sNy = -1
602              err = NF_INQ_ATT(fid,NF_GLOBAL, 'sNx',atype,alen)
603              IF ((err .EQ. NF_NOERR) .AND. (alen .EQ. 1)) THEN
604                err = NF_GET_ATT_INT(fid, NF_GLOBAL, 'sNx', f_sNx)
605                CALL MNC_HANDLE_ERR(err,
606         &           'reading attribute ''sNx'' in S/R MNC_CW_RX_R',
607         &           myThid)
608              ENDIF
609              err = NF_INQ_ATT(fid,NF_GLOBAL, 'sNy',atype,alen)
610              IF ((err .EQ. NF_NOERR) .AND. (alen .EQ. 1)) THEN
611                err = NF_GET_ATT_INT(fid, NF_GLOBAL, 'sNy', f_sNy)
612                CALL MNC_HANDLE_ERR(err,
613         &           'reading attribute ''sNy'' in S/R MNC_CW_RX_R',
614         &           myThid)
615              ENDIF
616              IF ((f_sNx .NE. sNx) .OR. (f_sNy .NE. sNy)) THEN
617                write(msgbuf,'(5a)') 'MNC_CW_RX_R WARNING: the ',
618         &           'attributes ''sNx'' and ''sNy'' within the file ''',
619         &           fname(1:nfname), ''' do not exist or do not match ',
620         &           'the current sizes within the model'
621                CALL print_error(msgbuf, mythid)
622              ENDIF
623    
624    C         Check that the in-memory variable and the in-file variables
625    C         are of compatible sizes
626    C           ires = 1
627    C           CALL MNC_CHK_VTYP_R_NCVAR( ind_vt,
628    C      &         indf, ind_fv_ids, indu, ires)
629    C           IF (ires .LT. 0) THEN
630    C             write(msgbuf,'(7a)') 'MNC_CW_RX_R WARNING: the sizes ',
631    C      &           'of the in-program variable ''', vtype(nvf:nvl),
632    C      &           ''' and the corresponding variable within file ''',
633    C      &           fname(1:nfname), ''' are not compatible -- please ',
634    C      &           'check the sizes'
635    C             CALL print_error(msgbuf, mythid)
636    C             STOP 'ABNORMAL END: S/R MNC_CW_RX_R'
637    C           ENDIF
638    
639    C         Check for bi,bj indicies
640              bidim = mnc_cw_vbij(1,ind_vt)
641              bjdim = mnc_cw_vbij(2,ind_vt)
642    
643    C         Set the dimensions for the in-memory array
644              ndim = mnc_cw_ndim(igrid)
645              k = mnc_cw_dims(1,igrid)
646              IF (k .GT. 0) THEN
647                p(1) = k
648              ELSE
649                p(1) = 1
650              ENDIF
651              DO i = 2,9
652                k = mnc_cw_dims(i,igrid)
653                IF (k .LT. 1) THEN
654                  k = 1
655                ENDIF
656                IF ((bidim .GT. 0) .AND. (i .EQ. bidim)) THEN
657                  p(i) = nSx * p(i-1)
658                ELSEIF ((bjdim .GT. 0) .AND. (i .EQ. bjdim)) THEN
659                  p(i) = nSy * p(i-1)
660                ELSE
661                  p(i) = k * p(i-1)
662                ENDIF
663              ENDDO
664    
665    C         Set starting and ending indicies for the in-memory array and
666    C         the unlimited dimension offset for the NetCDF array
667              DO i = 1,9
668                udo(i) = 0
669                s(i) = 1
670                e(i) = 1
671                IF (i .LE. ndim) THEN
672                  s(i) = mnc_cw_is(i,igrid)
673                  e(i) = mnc_cw_ie(i,igrid)
674                ENDIF
675    C           Check for the unlimited dimension
676                IF ((i .EQ. ndim)
677         &           .AND. (mnc_cw_dims(i,igrid) .EQ. -1)) THEN
678                  IF (indu .GT. 0) THEN
679    C               Use the indu value
680                    udo(i) = indu - 1
681                  ELSEIF (indu .EQ. -1) THEN
682    C               Append one to the current unlimited dim size
683                    CALL MNC_DIM_UNLIM_SIZE( fname, unlim_sz, myThid)
684                    udo(i) = unlim_sz
685                  ELSE
686    C               Use the current unlimited dim size
687                    CALL MNC_DIM_UNLIM_SIZE( fname, unlim_sz, myThid)
688                    udo(i) = unlim_sz - 1
689                  ENDIF
690                ENDIF
691              ENDDO
692              IF (bidim .GT. 0) THEN
693                s(bidim) = lbi
694                e(bidim) = lbi
695              ENDIF
696              IF (bjdim .GT. 0) THEN
697                s(bjdim) = lbj
698                e(bjdim) = lbj
699              ENDIF
700    
701    C     DO i = 9,1,-1
702    C     write(*,*) 'i,p(i),s(i),e(i) = ', i,': ',p(i),s(i),e(i)
703    C     ENDDO
704              
705              CALL MNC_FILE_ENDDEF(fname, myThid)
706    
707              write(msgbuf,'(5a)') 'reading variable type ''',
708         &         vtype(nvf:nvl), ''' within file ''',
709         &         fname(1:nfname), ''''
710    
711    C         Read the variable one vector at a time
712              DO j7 = s(7),e(7)
713                k7 = (j7 - 1)*p(6)
714                vstart(7) = udo(7) + j7 - s(7) + 1
715                vcount(7) = 1
716                DO j6 = s(6),e(6)
717                  k6 = (j6 - 1)*p(5) + k7
718                  vstart(6) = udo(6) + j6 - s(6) + 1
719                  vcount(6) = 1
720                  DO j5 = s(5),e(5)
721                    k5 = (j5 - 1)*p(4) + k6
722                    vstart(5) = udo(5) + j5 - s(5) + 1
723                    vcount(5) = 1
724                    DO j4 = s(4),e(4)
725                      k4 = (j4 - 1)*p(3) + k5
726                      vstart(4) = udo(4) + j4 - s(4) + 1
727                      vcount(4) = 1
728                      DO j3 = s(3),e(3)
729                        k3 = (j3 - 1)*p(2) + k4
730                        vstart(3) = udo(3) + j3 - s(3) + 1
731                        vcount(3) = 1
732                        DO j2 = s(2),e(2)
733                          k2 = (j2 - 1)*p(1) + k3
734                          vstart(2) = udo(2) + j2 - s(2) + 1
735                          vcount(2) = 1
736    
737          kr = 0
738          vstart(1) = udo(1) + 1
739          vcount(1) = e(1) - s(1) + 1
740          
741          IF (stype(1:1) .EQ. 'D') THEN
742            err = NF_GET_VARA_DOUBLE(fid, idv, vstart, vcount, resh_d)
743            CALL MNC_HANDLE_ERR(err, msgbuf, myThid)
744            DO j1 = s(1),e(1)
745              k1 = k2 + j1
746              kr = kr + 1
747              var(k1) = resh_d(kr)
748            ENDDO
749          ENDIF
750          IF (stype(1:1) .EQ. 'R') THEN
751            err = NF_GET_VARA_REAL(fid, idv, vstart, vcount, resh_r)
752            CALL MNC_HANDLE_ERR(err, msgbuf, myThid)
753            DO j1 = s(1),e(1)
754              k1 = k2 + j1
755              kr = kr + 1
756              var(k1) = resh_r(kr)
757            ENDDO
758          ENDIF
759          IF (stype(1:1) .EQ. 'I') THEN
760            err = NF_GET_VARA_INT(fid, idv, vstart, vcount, resh_i)
761            CALL MNC_HANDLE_ERR(err, msgbuf, myThid)
762            DO j1 = s(1),e(1)
763              k1 = k2 + j1
764              kr = kr + 1
765              var(k1) = resh_i(kr)
766            ENDDO
767          ENDIF
768    
769  C         Write the variable one row at a time        
770    
771                        ENDDO
772                      ENDDO
773                    ENDDO
774                  ENDDO
775                ENDDO
776              ENDDO
777    
778    C         Close the file
779              CALL MNC_FILE_CLOSE(fname, myThid)
780    
781    C         End the lbj,lbi loops
782          ENDDO          ENDDO
783        ENDDO        ENDDO
784    

Legend:
Removed from v.1.1  
changed lines
  Added in v.1.22

  ViewVC Help
Powered by ViewVC 1.1.22