/[MITgcm]/MITgcm/pkg/diagnostics/diagnostics_out.F
ViewVC logotype

Diff of /MITgcm/pkg/diagnostics/diagnostics_out.F

Parent Directory Parent Directory | Revision Log Revision Log | View Revision Graph Revision Graph | View Patch Patch

revision 1.5 by edhill, Wed Dec 29 02:13:38 2004 UTC revision 1.29 by jmc, Mon Jun 5 18:17:23 2006 UTC
# Line 9  C     !ROUTINE: DIAGNOSTICS_OUT Line 9  C     !ROUTINE: DIAGNOSTICS_OUT
9    
10  C     !INTERFACE:  C     !INTERFACE:
11        SUBROUTINE  DIAGNOSTICS_OUT(        SUBROUTINE  DIAGNOSTICS_OUT(
12       I     listnum,       I     listId,
13       I     myIter,       I     myIter,
14         I     myTime,
15       I     myThid )       I     myThid )
16    
17  C     !DESCRIPTION:  C     !DESCRIPTION:
18  C     Write output for diagnostics fields.  C     Write output for diagnostics fields.
19          
20  C     !USES:  C     !USES:
21        IMPLICIT NONE        IMPLICIT NONE
22  #include "SIZE.h"  #include "SIZE.h"
23  #include "EEPARAMS.h"  #include "EEPARAMS.h"
24  #include "PARAMS.h"  #include "PARAMS.h"
25    #include "GRID.h"
26  #include "DIAGNOSTICS_SIZE.h"  #include "DIAGNOSTICS_SIZE.h"
27  #include "DIAGNOSTICS.h"  #include "DIAGNOSTICS.h"
28    
# Line 33  C     !USES: Line 35  C     !USES:
35    
36    
37  C     !INPUT PARAMETERS:  C     !INPUT PARAMETERS:
38  C     listnum :: Diagnostics list number being written  C     listId  :: Diagnostics list number being written
39  C     myIter  :: current iteration number  C     myIter  :: current iteration number
40    C     myTime  :: current time of simulation (s)
41  C     myThid  :: my Thread Id number  C     myThid  :: my Thread Id number
42        INTEGER listnum, myIter, myThid        _RL     myTime
43          INTEGER listId, myIter, myThid
44  CEOP  CEOP
45    
46  C     !LOCAL VARIABLES:  C     !LOCAL VARIABLES:
47        INTEGER i, j, k, m, n, bi, bj  C     i,j,k :: loop indices
48    C     lm    :: loop index (averageCycle)
49    C     md    :: field number in the list "listId".
50    C     ndId  :: diagnostics  Id number (in available diagnostics list)
51    C     mate  :: counter mate Id number (in available diagnostics list)
52    C     ip    :: diagnostics  pointer to storage array
53    C     im    :: counter-mate pointer to storage array
54          INTEGER i, j, k, lm
55          INTEGER bi, bj
56          INTEGER md, ndId, ip, im
57          INTEGER mate, mVec
58        CHARACTER*8 parms1        CHARACTER*8 parms1
       CHARACTER*3 mate_index  
       INTEGER mate  
59        _RL qtmp1(1-OLx:sNx+OLx,1-OLy:sNy+OLy,Nr+Nrphys,nSx,nSy)        _RL qtmp1(1-OLx:sNx+OLx,1-OLy:sNy+OLy,Nr+Nrphys,nSx,nSy)
       _RL qtmp2(1-OLx:sNx+OLx,1-OLy:sNy+OLy,Nr+Nrphys,nSx,nSy)  
60        _RL undef, getcon        _RL undef, getcon
61        EXTERNAL getcon        EXTERNAL getcon
62        INTEGER ILNBLNK        INTEGER ILNBLNK
63        EXTERNAL ILNBLNK        EXTERNAL ILNBLNK
64        INTEGER ilen        INTEGER ilen
65          INTEGER nlevsout
66    
67        CHARACTER*(MAX_LEN_FNAM) pref        INTEGER ioUnit
68          CHARACTER*(MAX_LEN_FNAM) fn
69        CHARACTER*(MAX_LEN_MBUF) suff        CHARACTER*(MAX_LEN_MBUF) suff
70        CHARACTER*(MAX_LEN_MBUF) msgBuf        CHARACTER*(MAX_LEN_MBUF) msgBuf
71        CHARACTER*(80) fn  #ifdef ALLOW_MDSIO
72        LOGICAL glf        LOGICAL glf
73          INTEGER nRec
74    #endif
75  #ifdef ALLOW_MNC  #ifdef ALLOW_MNC
76        INTEGER ii        INTEGER ii
77        CHARACTER*(MAX_LEN_FNAM) diag_mnc_bn        CHARACTER*(MAX_LEN_FNAM) diag_mnc_bn
   
78        INTEGER CW_DIMS, NLEN        INTEGER CW_DIMS, NLEN
79        PARAMETER ( CW_DIMS = 10 )        PARAMETER ( CW_DIMS = 10 )
80        PARAMETER ( NLEN    = 80 )        PARAMETER ( NLEN    = 80 )
81        INTEGER dim(CW_DIMS), ib(CW_DIMS), ie(CW_DIMS)        INTEGER dim(CW_DIMS), ib(CW_DIMS), ie(CW_DIMS)
82        CHARACTER*(NLEN) dn(CW_DIMS)        CHARACTER*(NLEN) dn(CW_DIMS)
83          CHARACTER*(NLEN) d_cw_name
84        CHARACTER*(NLEN) dn_blnk        CHARACTER*(NLEN) dn_blnk
85    #ifdef DIAG_MNC_COORD_NEEDSWORK
86          CHARACTER*(5) ctmp
87          _RS ztmp(Nr+Nrphys)
88    #endif
89  #endif /*  ALLOW_MNC  */  #endif /*  ALLOW_MNC  */
90    
91  C---+----1----+----2----+----3----+----4----+----5----+----6----+----7-|--+----|  C---+----1----+----2----+----3----+----4----+----5----+----6----+----7-|--+----|
92    
93          ioUnit= standardMessageUnit
94        undef = getcon('UNDEF')        undef = getcon('UNDEF')
       glf = globalFiles  
95        WRITE(suff,'(I10.10)') myIter        WRITE(suff,'(I10.10)') myIter
96        pref = fnames(listnum)        ilen = ILNBLNK(fnames(listId))
97        ilen=ILNBLNK( pref )        WRITE( fn, '(A,A,A)' ) fnames(listId)(1:ilen),'.',suff(1:10)
       WRITE( fn, '(A,A,A)' ) pref(1:ilen),'.',suff(1:10)  
98    
99  #ifdef ALLOW_MNC  #ifdef ALLOW_MNC
100        IF (useMNC .AND. diag_mnc) THEN        IF (useMNC .AND. diag_mnc) THEN
# Line 86  C---+----1----+----2----+----3----+----4 Line 104  C---+----1----+----2----+----3----+----4
104          DO i = 1,NLEN          DO i = 1,NLEN
105            dn_blnk(i:i) = ' '            dn_blnk(i:i) = ' '
106          ENDDO          ENDDO
107  c       WRITE( diag_mnc_bn, '(A,A)' ) 'diag.', pref(1:ilen)          WRITE( diag_mnc_bn, '(A)' ) fnames(listId)(1:ilen)
         WRITE( diag_mnc_bn, '(A)' ) pref(1:ilen)  
108    
109  C       Update the record dimension by writing the iteration number  C       Update the record dimension by writing the iteration number
110          CALL MNC_CW_SET_UDIM(diag_mnc_bn, -1, myThid)          CALL MNC_CW_SET_UDIM(diag_mnc_bn, -1, myThid)
111          CALL MNC_CW_I_W_S('I',diag_mnc_bn,0,0,'T',myIter,myThid)          CALL MNC_CW_RL_W_S('D',diag_mnc_bn,0,0,'T',myTime,myThid)
112          CALL MNC_CW_SET_UDIM(diag_mnc_bn, 0, myThid)          CALL MNC_CW_SET_UDIM(diag_mnc_bn, 0, myThid)
113            CALL MNC_CW_I_W_S('I',diag_mnc_bn,0,0,'iter',myIter,myThid)
114    
115    C       NOTE: at some point it would be a good idea to add a time_bounds
116    C       variable that has dimension (2,T) and clearly denotes the
117    C       beginning and ending times for each diagnostics period
118    
119          dn(1)(1:NLEN) = dn_blnk(1:NLEN)          dn(1)(1:NLEN) = dn_blnk(1:NLEN)
120          WRITE(dn(1),'(a,i6.6)') 'Zd', nlevels(listnum)          WRITE(dn(1),'(a,i6.6)') 'Zmd', nlevels(listId)
121          dim(1) = nlevels(listnum)          dim(1) = nlevels(listId)
122          ib(1)  = 1          ib(1)  = 1
123          ie(1)  = nlevels(listnum)          ie(1)  = nlevels(listId)
124    
125          CALL MNC_CW_ADD_GNAME('diag_levels', 1,          CALL MNC_CW_ADD_GNAME('diag_levels', 1,
126       &       dim, dn, ib, ie, myThid)       &       dim, dn, ib, ie, myThid)
127          CALL MNC_CW_ADD_VNAME(dn(1), 'diag_levels',          CALL MNC_CW_ADD_VNAME('diag_levels', 'diag_levels',
128       &       0,0, myThid)       &       0,0, myThid)
129          CALL MNC_CW_ADD_VATTR_TEXT(dn(1),'description',          CALL MNC_CW_ADD_VATTR_TEXT('diag_levels','description',
130       &    'Idicies of vertical levels within the data source arrays',       &       'Idicies of vertical levels within the source arrays',
131       &       myThid)       &       myThid)
           
         CALL MNC_CW_RL_W('I',diag_mnc_bn,0,0,  
      &       dn(1), levs(1,listnum), myThid)  
132    
133          CALL MNC_CW_DEL_VNAME(dn(1), myThid)          CALL MNC_CW_RL_W('D',diag_mnc_bn,0,0,
134         &       'diag_levels', levs(1,listId), myThid)
135    
136            CALL MNC_CW_DEL_VNAME('diag_levels', myThid)
137          CALL MNC_CW_DEL_GNAME('diag_levels', myThid)          CALL MNC_CW_DEL_GNAME('diag_levels', myThid)
138    
139    #ifdef DIAG_MNC_COORD_NEEDSWORK
140    C       This part has been placed in an #ifdef because, as its currently
141    C       written, it will only work with variables defined on a dynamics
142    C       grid.  As we start using diagnostics for physics grids, ice
143    C       levels, land levels, etc. the different vertical coordinate
144    C       dimensions will have to be taken into account.
145    
146    C       20051021 JMC & EH3 : We need to extend this so that a few
147    C       variables each defined on different grids do not have the same
148    C       vertical dimension names so we should be using a pattern such
149    C       as: Z[uml]td000000 where the 't' is the type as specified by
150    C       gdiag(10)
151    
152    C       Now define:  Zmdxxxxxx, Zudxxxxxx, Zldxxxxxx
153            ctmp(1:5) = 'mul  '
154            DO i = 1,3
155              dn(1)(1:NLEN) = dn_blnk(1:NLEN)
156              WRITE(dn(1),'(3a,i6.6)') 'Z',ctmp(i:i),'d',nlevels(listId)
157              CALL MNC_CW_ADD_GNAME(dn(1), 1, dim, dn, ib, ie, myThid)
158              CALL MNC_CW_ADD_VNAME(dn(1), dn(1), 0,0, myThid)
159    
160    C         The following three ztmp() loops should eventually be modified
161    C         to reflect the fractional nature of levs(j,l) -- they should
162    C         do something like:
163    C            ztmp(j) = rC(INT(FLOOR(levs(j,l))))
164    C                      + ( rC(INT(FLOOR(levs(j,l))))
165    C                          + rC(INT(CEIL(levs(j,l)))) )
166    C                        / ( levs(j,l) - FLOOR(levs(j,l)) )
167    C         for averaged levels.
168              IF (i .EQ. 1) THEN
169                DO j = 1,nlevels(listId)
170                  ztmp(j) = rC(NINT(levs(j,listId)))
171                ENDDO
172                CALL MNC_CW_ADD_VATTR_TEXT(dn(1),'description',
173         &           'Dimensional coordinate value at the mid point',
174         &           myThid)
175              ELSEIF (i .EQ. 2) THEN
176                DO j = 1,nlevels(listId)
177                  ztmp(j) = rF(NINT(levs(j,listId)) + 1)
178                ENDDO
179                CALL MNC_CW_ADD_VATTR_TEXT(dn(1),'description',
180         &           'Dimensional coordinate value at the upper point',
181         &           myThid)
182              ELSEIF (i .EQ. 3) THEN
183                DO j = 1,nlevels(listId)
184                  ztmp(j) = rF(NINT(levs(j,listId)))
185                ENDDO
186                CALL MNC_CW_ADD_VATTR_TEXT(dn(1),'description',
187         &           'Dimensional coordinate value at the lower point',
188         &           myThid)
189              ENDIF
190              CALL MNC_CW_RS_W('D',diag_mnc_bn,0,0, dn(1), ztmp, myThid)
191              CALL MNC_CW_DEL_VNAME(dn(1), myThid)
192              CALL MNC_CW_DEL_GNAME(dn(1), myThid)
193            ENDDO
194    #endif /*  DIAG_MNC_COORD_NEEDSWORK  */
195    
196        ENDIF        ENDIF
197  #endif /*  ALLOW_MNC  */  #endif /*  ALLOW_MNC  */
198    
199        DO n = 1,nfields(listnum)  C---+----1----+----2----+----3----+----4----+----5----+----6----+----7-|--+----|
200          m = jdiag(n,listnum)  
201          parms1 = gdiag(m)(1:8)        DO md = 1,nfields(listId)
202          IF ( idiag(m).NE.0 .AND. parms1(5:5).NE.'D' ) THEN          ndId = jdiag(md,listId)
203            parms1 = gdiag(ndId)(1:8)
204            mate = 0
205            mVec = 0
206            IF ( parms1(5:5).EQ.'C' ) THEN
207    C-      Check for Mate of a Counter Diagnostic
208               READ(parms1,'(5X,I3)') mate
209            ELSEIF ( parms1(1:1).EQ.'U' .OR. parms1(1:1).EQ.'V' ) THEN
210    C-      Check for Mate of a Vector Diagnostic
211               READ(parms1,'(5X,I3)') mVec
212            ENDIF
213            IF ( idiag(md,listId).NE.0 .AND. parms1(5:5).NE.'D' ) THEN
214  C--     Start processing 1 Fld :  C--     Start processing 1 Fld :
215             DO lm=1,averageCycle(listId)
216    
217              ip = ABS(idiag(md,listId)) + kdiag(ndId)*(lm-1)
218              im = mdiag(md,listId)
219              IF (mate.GT.0) im = im + kdiag(mate)*(lm-1)
220              IF (mVec.GT.0) im = im + kdiag(mVec)*(lm-1)
221    
222            IF ( ndiag(m).EQ.0 ) THEN            IF ( ndiag(ip,1,1).EQ.0 ) THEN
223  C-        Empty diagnostics case :  C-        Empty diagnostics case :
224    
225              _BEGIN_MASTER( myThid )              _BEGIN_MASTER( myThid )
226              WRITE(msgBuf,'(A,I10)')              WRITE(msgBuf,'(A,I10)')
227       &        '- WARNING - from DIAGNOSTICS_OUT at iter=', myIter       &        '- WARNING - from DIAGNOSTICS_OUT at iter=', myIter
228              CALL PRINT_MESSAGE( msgBuf, errorMessageUnit,              CALL PRINT_MESSAGE( msgBuf, errorMessageUnit,
229       &                          SQUEEZE_RIGHT, myThid)       &                          SQUEEZE_RIGHT, myThid)
230              WRITE(msgBuf,'(A,I4,3A,I3,2A)')              WRITE(msgBuf,'(A,I4,3A,I3,2A)')
231       &       '- WARNING -   diag.#',m, ' : ',flds(n,listnum),       &       '- WARNING -   diag.#',ndId, ' : ',flds(md,listId),
232       &       ' (#',n,' ) in outp.Stream: ',fnames(listnum)       &       ' (#',md,' ) in outp.Stream: ',fnames(listId)
233              CALL PRINT_MESSAGE( msgBuf, errorMessageUnit,              CALL PRINT_MESSAGE( msgBuf, errorMessageUnit,
234       &                          SQUEEZE_RIGHT, myThid)       &                          SQUEEZE_RIGHT, myThid)
235              WRITE(msgBuf,'(A,I2,A)')              IF ( averageCycle(listId).GT.1 ) THEN
236       &       '- WARNING -   has not been filled (ndiag=',ndiag(m),' )'               WRITE(msgBuf,'(A,2(I2,A))')
237              CALL PRINT_MESSAGE( msgBuf, errorMessageUnit,       &        '- WARNING -   has not been filled (ndiag(lm=',lm,')=',
238         &                                            ndiag(ip,1,1), ' )'
239                ELSE
240                 WRITE(msgBuf,'(A,2(I2,A))')
241         &        '- WARNING -   has not been filled (ndiag=',
242         &                                            ndiag(ip,1,1), ' )'
243                ENDIF
244                CALL PRINT_MESSAGE( msgBuf, errorMessageUnit,
245       &                          SQUEEZE_RIGHT, myThid)       &                          SQUEEZE_RIGHT, myThid)
246              WRITE(msgBuf,'(A)')              WRITE(msgBuf,'(A)')
247       &       'WARNING DIAGNOSTICS_OUT  => write ZEROS instead'       &       'WARNING DIAGNOSTICS_OUT  => write ZEROS instead'
248              CALL PRINT_MESSAGE( msgBuf, errorMessageUnit,              CALL PRINT_MESSAGE( msgBuf, errorMessageUnit,
249       &                          SQUEEZE_RIGHT, myThid)       &                          SQUEEZE_RIGHT, myThid)
250              _END_MASTER( myThid )              _END_MASTER( myThid )
251              DO bj = myByLo(myThid), myByHi(myThid)              DO bj = myByLo(myThid), myByHi(myThid)
252                DO bi = myBxLo(myThid), myBxHi(myThid)                DO bi = myBxLo(myThid), myBxHi(myThid)
253                  DO k = 1,nlevels(listnum)                  DO k = 1,nlevels(listId)
254                    DO j = 1-OLy,sNy+OLy                    DO j = 1-OLy,sNy+OLy
255                      DO i = 1-OLx,sNx+OLx                      DO i = 1-OLx,sNx+OLx
256                        qtmp1(i,j,k,bi,bj) = 0. _d 0                        qtmp1(i,j,k,bi,bj) = 0. _d 0
# Line 159  C-        Empty diagnostics case : Line 263  C-        Empty diagnostics case :
263            ELSE            ELSE
264  C-        diagnostics is not empty :  C-        diagnostics is not empty :
265    
266              IF ( myThid.EQ.1 )              IF ( debugLevel.GE.debLevA .AND. myThid.EQ.1 ) THEN
267       &             WRITE(6,2000) m,cdiag(m),ndiag(m),gdiag(m)                WRITE(ioUnit,'(A,I3,3A,I8,2A)')
268              IF ( parms1(5:5).NE.'C' ) THEN       &         ' Computing Diagnostic # ', ndId, '  ', cdiag(ndId),
269         &         '     Counter:',ndiag(ip,1,1),'   Parms: ',gdiag(ndId)
270                DO k = 1,nlevels(listnum)                IF ( mate.GT.0 ) THEN
271                  CALL GETDIAG (levs(k,listnum),m,undef,qtmp1,myThid)                 WRITE(ioUnit,'(3A,I3,2A)')
272                ENDDO       &         '       use Counter Mate for  ', cdiag(ndId),
273         &         '     Diagnostic # ',mate, '  ', cdiag(mate)
274  C             Check for Mate of a Vector Diagnostic                ELSEIF ( mVec.GT.0 ) THEN
275  C             -------------------------------------                  IF ( im.GT.0 .AND. ndiag(MAX(1,im),1,1).GT.0 ) THEN
276                IF ( parms1(1:1).EQ.'U' .OR. parms1(1:1).EQ.'V' ) THEN                   WRITE(ioUnit,'(3A,I3,3A)')
277                  mate_index = parms1(6:8)       &             '           Vector  Mate for  ', cdiag(ndId),
278                  READ (mate_index,'(I3)') mate       &             '     Diagnostic # ',mVec, '  ', cdiag(mVec),
279                  IF ( idiag(mate).NE.0 ) THEN       &             ' exists '
                   IF ( myThid.EQ.1 )  
      &                 WRITE(6,2001) cdiag(m),mate,cdiag(mate)  
280                  ELSE                  ELSE
281                    IF ( myThid.EQ.1 )                   WRITE(ioUnit,'(3A,I3,3A)')
282       &                 WRITE(6,2002) cdiag(m),mate,cdiag(mate)       &             '           Vector  Mate for  ', cdiag(ndId),
283         &             '     Diagnostic # ',mVec, '  ', cdiag(mVec),
284         &             ' not enabled'
285                  ENDIF                  ENDIF
286                ENDIF                ENDIF
287                                ENDIF
             ELSE  
288    
289  C             Check for Mate of a Counter Diagnostic              DO bj = myByLo(myThid), myByHi(myThid)
290  C             --------------------------------------               DO bi = myBxLo(myThid), myBxHi(myThid)
291                mate_index = parms1(6:8)                DO k = 1,nlevels(listId)
292                READ (mate_index,'(I3)') mate                  CALL GETDIAG(
293                IF ( myThid.EQ.1 )       I                       levs(k,listId),undef,
294       &                 WRITE(6,2003) cdiag(m),mate,cdiag(mate)       O                       qtmp1(1-OLx,1-OLy,k,bi,bj),
295                DO k = 1,nlevels(listnum)       I                       ndId,mate,ip,im,bi,bj,myThid)
                 CALL getdiag2(levs(k,listnum),m,undef,qtmp1,myThid)  
                 CALL getdiag2(levs(k,listnum),mate,undef,qtmp2,myThid)  
                 DO bj = myByLo(myThid), myByHi(myThid)  
                   DO bi = myBxLo(myThid), myBxHi(myThid)  
                     DO j = 1,sNy  
                       DO i = 1,sNx  
                         IF (qtmp2(i,j,k,bi,bj).NE.0.) THEN  
                           qtmp1(i,j,k,bi,bj) =  
      &                         qtmp1(i,j,k,bi,bj) / qtmp2(i,j,k,bi,bj)  
                         ELSE  
                           qtmp1(i,j,k,bi,bj) = undef  
                         ENDIF  
                       ENDDO  
                     ENDDO  
                   ENDDO  
                 ENDDO  
296                ENDDO                ENDDO
297                 ENDDO
298              ENDIF              ENDDO
299    
300  C-        end of empty diag / not empty block  C-        end of empty diag / not empty block
301            ENDIF            ENDIF
302    
303              nlevsout = nlevels(listId)
304    
305    C-----------------------------------------------------------------------
306    C         Check to see if we need to interpolate before output
307    C-----------------------------------------------------------------------
308              IF ( fflags(listId)(2:2).EQ.'P' ) THEN
309    C-        Do vertical interpolation:
310    c          IF ( fluidIsAir ) THEN
311    C jmc: for now, this can only work in an atmospheric set-up (fluidIsAir);
312    C      find some problems with 5-levels AIM => use it only with FIZHI
313               IF ( useFIZHI ) THEN
314                CALL DIAGNOSTICS_INTERP_VERT(
315         I                     listId, md, ndId, ip, im,
316         U                     nlevsout,
317         U                     qtmp1,
318         I                     undef,
319         I                     myTime, myIter, myThid )
320               ELSE
321                 WRITE(msgBuf,'(2A)') 'DIAGNOSTICS_OUT: ',
322         &         'INTERP_VERT not safe in this config'
323                 CALL PRINT_ERROR( msgBuf , myThid )
324                 WRITE(msgBuf,'(2A,I3,2A)') 'DIAGNOSTICS_OUT: ',
325         &         ' for list l=', listId, ', filename: ', fnames(listId)
326                 CALL PRINT_ERROR( msgBuf , myThid )
327                 STOP 'ABNORMAL END: S/R DIAGNOSTICS_OUT'
328               ENDIF
329              ENDIF
330    
331  #ifdef ALLOW_MDSIO  #ifdef ALLOW_MDSIO
332  C         Prepare for mdsio optionality  C         Prepare for mdsio optionality
333            IF (diag_mdsio) THEN            IF (diag_mdsio) THEN
334              CALL mdswritefield_new(fn,writeBinaryPrec,glf,'RL',              glf = globalFiles
335       &           Nr+Nrphys,nlevels(listnum),qtmp1,n,myIter,myThid)              nRec = lm + (md-1)*averageCycle(listId)
336                IF (fflags(listId)(1:1) .EQ. 'R') THEN
337    C             Force it to be 32-bit precision
338                  CALL MDSWRITEFIELD_NEW(fn,precFloat32,glf,.FALSE.,
339         &             'RL',Nr+Nrphys,nlevsout,qtmp1,nRec,myIter,myThid)
340                ELSEIF (fflags(listId)(1:1) .EQ. 'D') THEN
341    C             Force it to be 64-bit precision
342                  CALL MDSWRITEFIELD_NEW(fn,precFloat64,glf,.FALSE.,
343         &             'RL',Nr+Nrphys,nlevsout,qtmp1,nRec,myIter,myThid)
344                ELSE
345    C             This is the old default behavior
346                  CALL MDSWRITEFIELD_NEW(fn,writeBinaryPrec,glf,.FALSE.,
347         &             'RL',Nr+Nrphys,nlevsout,qtmp1,nRec,myIter,myThid)
348                ENDIF
349            ENDIF            ENDIF
350  #endif /*  ALLOW_MDSIO  */  #endif /*  ALLOW_MDSIO  */
351    
# Line 227  C         Prepare for mdsio optionality Line 355  C         Prepare for mdsio optionality
355              _BEGIN_MASTER( myThid )              _BEGIN_MASTER( myThid )
356    
357              DO ii = 1,CW_DIMS              DO ii = 1,CW_DIMS
358                  d_cw_name(1:NLEN) = dn_blnk(1:NLEN)
359                dn(ii)(1:NLEN) = dn_blnk(1:NLEN)                dn(ii)(1:NLEN) = dn_blnk(1:NLEN)
360              ENDDO              ENDDO
361    
362    C           Note that the "d_cw_name" variable is a hack that hides a
363    C           subtlety within MNC.  Basically, each MNC-wrapped file is
364    C           caching its own concept of what each "grid name" (that is, a
365    C           dimension group name) means.  So one cannot re-use the same
366    C           "grid" name for different collections of dimensions within a
367    C           given file.  By appending the "ndId" values to each name, we
368    C           guarantee uniqueness within each MNC-produced file.
369                WRITE(d_cw_name,'(a,i6.6)') 'd_cw_',ndId
370    
371  C           XY dimensions  C           XY dimensions
372              dim(1)       = sNx + 2*OLx              dim(1)       = sNx + 2*OLx
373              dim(2)       = sNy + 2*OLy              dim(2)       = sNy + 2*OLy
374              ib(1)        = OLx + 1              ib(1)        = OLx + 1
375              ib(2)        = OLy + 1              ib(2)        = OLy + 1
376              IF (gdiag(n)(2:2) .EQ. 'M') THEN              IF (gdiag(ndId)(2:2) .EQ. 'M') THEN
377                dn(1)(1:2) = 'X'                dn(1)(1:2) = 'X'
378                ie(1)      = OLx + sNx                ie(1)      = OLx + sNx
379                dn(2)(1:2) = 'Y'                dn(2)(1:2) = 'Y'
380                ie(2)      = OLy + sNy                ie(2)      = OLy + sNy
381              ELSEIF (gdiag(n)(2:2) .EQ. 'U') THEN              ELSEIF (gdiag(ndId)(2:2) .EQ. 'U') THEN
382                dn(1)(1:3) = 'Xp1'                dn(1)(1:3) = 'Xp1'
383                ie(1)      = OLx + sNx + 1                ie(1)      = OLx + sNx + 1
384                dn(2)(1:2) = 'Y'                dn(2)(1:2) = 'Y'
385                ie(2)      = OLy + sNy                ie(2)      = OLy + sNy
386              ELSEIF (gdiag(n)(2:2) .EQ. 'V') THEN              ELSEIF (gdiag(ndId)(2:2) .EQ. 'V') THEN
387                dn(1)(1:2) = 'X'                dn(1)(1:2) = 'X'
388                ie(1)      = OLx + sNx                ie(1)      = OLx + sNx
389                dn(2)(1:3) = 'Yp1'                dn(2)(1:3) = 'Yp1'
390                ie(2)      = OLy + sNy + 1                ie(2)      = OLy + sNy + 1
391              ELSEIF (gdiag(n)(2:2) .EQ. 'Z') THEN              ELSEIF (gdiag(ndId)(2:2) .EQ. 'Z') THEN
392                dn(1)(1:3) = 'Xp1'                dn(1)(1:3) = 'Xp1'
393                ie(1)      = OLx + sNx + 1                ie(1)      = OLx + sNx + 1
394                dn(2)(1:3) = 'Yp1'                dn(2)(1:3) = 'Yp1'
395                ie(2)      = OLy + sNy + 1                ie(2)      = OLy + sNy + 1
396              ENDIF              ENDIF
397                
398  C           Z is special since it varies  C           Z is special since it varies
399              WRITE(dn(3),'(a,i6.6)') 'Zd', nlevels(listnum)              WRITE(dn(3),'(a,i6.6)') 'Zd', nlevsout
400                IF ( (gdiag(ndId)(10:10) .EQ. 'R')
401         &           .AND. (gdiag(ndId)(9:9) .EQ. 'M') ) THEN
402                  WRITE(dn(3),'(a,i6.6)') 'Zmd', nlevsout
403                ENDIF
404                IF ( (gdiag(ndId)(10:10) .EQ. 'R')
405         &           .AND. (gdiag(ndId)(9:9) .EQ. 'L') ) THEN
406                  WRITE(dn(3),'(a,i6.6)') 'Zld', nlevsout
407                ENDIF
408                IF ( (gdiag(ndId)(10:10) .EQ. 'R')
409         &           .AND. (gdiag(ndId)(9:9) .EQ. 'U') ) THEN
410                  WRITE(dn(3),'(a,i6.6)') 'Zud', nlevsout
411                ENDIF
412              dim(3) = Nr+Nrphys              dim(3) = Nr+Nrphys
413              ib(3)  = 1              ib(3)  = 1
414              ie(3)  = nlevels(listnum)              ie(3)  = nlevsout
415    
416  C           Time dimension  C           Time dimension
417              dn(4)(1:1) = 'T'              dn(4)(1:1) = 'T'
# Line 269  C           Time dimension Line 419  C           Time dimension
419              ib(4)  = 1              ib(4)  = 1
420              ie(4)  = 1              ie(4)  = 1
421    
422              CALL MNC_CW_ADD_GNAME('diag_cw_temp', 4,              CALL MNC_CW_ADD_GNAME(d_cw_name, 4,
423       &             dim, dn, ib, ie, myThid)       &             dim, dn, ib, ie, myThid)
424              CALL MNC_CW_ADD_VNAME(cdiag(m), 'diag_cw_temp',              CALL MNC_CW_ADD_VNAME(cdiag(ndId), d_cw_name,
425       &             4,5, myThid)       &             4,5, myThid)
426              CALL MNC_CW_ADD_VATTR_TEXT(cdiag(m),'description',              CALL MNC_CW_ADD_VATTR_TEXT(cdiag(ndId),'description',
427       &             tdiag(m),myThid)       &             tdiag(ndId),myThid)
428              CALL MNC_CW_ADD_VATTR_TEXT(cdiag(m),'units',              CALL MNC_CW_ADD_VATTR_TEXT(cdiag(ndId),'units',
429       &             udiag(m),myThid)       &             udiag(ndId),myThid)
430    
431              CALL MNC_CW_RL_W('D',diag_mnc_bn,0,0,  C           Per the observations of Baylor, this has been commented out
432       &             cdiag(m), qtmp1, myThid)  C           until we have code that can write missing_value attributes
433    C           in a way thats compatible with most of the more popular
434    C           netCDF tools including ferret.  Using all-zeros completely
435    C           breaks ferret.
436    
437    C           CALL MNC_CW_ADD_VATTR_DBL(cdiag(ndId),'missing_value',
438    C           &             0.0 _d 0,myThid)
439    
440                IF ( ( (writeBinaryPrec .EQ. precFloat32)
441         &           .AND. (fflags(listId)(1:1) .NE. 'D')
442         &           .AND. (fflags(listId)(1:1) .NE. 'R') )
443         &           .OR. (fflags(listId)(1:1) .EQ. 'R')) THEN
444                  CALL MNC_CW_RL_W('R',diag_mnc_bn,0,0,
445         &             cdiag(ndId), qtmp1, myThid)
446                ELSEIF ( (writeBinaryPrec .EQ. precFloat64)
447         &             .OR. (fflags(listId)(1:1) .EQ. 'D') ) THEN
448                  CALL MNC_CW_RL_W('D',diag_mnc_bn,0,0,
449         &             cdiag(ndId), qtmp1, myThid)
450                ENDIF
451    
452              CALL MNC_CW_DEL_VNAME(cdiag(m), myThid)              CALL MNC_CW_DEL_VNAME(cdiag(ndId), myThid)
453              CALL MNC_CW_DEL_GNAME('diag_cw_temp', myThid)              CALL MNC_CW_DEL_GNAME(d_cw_name, myThid)
454    
455              _END_MASTER( myThid )              _END_MASTER( myThid )
456    
457            ENDIF            ENDIF
458  #endif /*  ALLOW_MNC  */  #endif /*  ALLOW_MNC  */
459    
460  C--     end of Processing Fld # n           ENDDO
461    C--     end of Processing Fld # md
462          ENDIF          ENDIF
463        ENDDO        ENDDO
464    
465   2000 format(1x,'Computing Diagnostic # ',i3,2x,a8,5x,'Counter: ',        RETURN
      &     i4,6x,'Parms: ',a16)  
  2001 format(1x,'          Vector  Mate for  ',a8,5x,  
      &     'Diagnostic # ',i3,2x,a8,' exists ')  
  2002 format(1x,'        Vector  Mate for  ',a8,5x,  
      &     'Diagnostic # ',i3,2x,a8,' not enabled')  
  2003 format(1x,'      use Counter Mate for  ',a8,5x,  
      &     'Diagnostic # ',i3,2x,a8)  
         
       RETURN  
466        END        END
467                                                                        
468  C---+----1----+----2----+----3----+----4----+----5----+----6----+----7-|--+----|  C---+----1----+----2----+----3----+----4----+----5----+----6----+----7-|--+----|

Legend:
Removed from v.1.5  
changed lines
  Added in v.1.29

  ViewVC Help
Powered by ViewVC 1.1.22