/[MITgcm]/MITgcm/pkg/atm_ocn_coupler/cpl_check_cplconfig.F
ViewVC logotype

Annotation of /MITgcm/pkg/atm_ocn_coupler/cpl_check_cplconfig.F

Parent Directory Parent Directory | Revision Log Revision Log | View Revision Graph Revision Graph


Revision 1.1 - (hide annotations) (download)
Mon Dec 2 23:25:38 2013 UTC (10 years, 6 months ago) by jmc
Branch: MAIN
CVS Tags: checkpoint64y, checkpoint64x, checkpoint64z, checkpoint64s, checkpoint64r, checkpoint64u, checkpoint64t, checkpoint64w, checkpoint64v, checkpoint65p, checkpoint65j, checkpoint65k, checkpoint65h, checkpoint65i, checkpoint65n, checkpoint65o, checkpoint65l, checkpoint65m, checkpoint65b, checkpoint65c, checkpoint65a, checkpoint65f, checkpoint65g, checkpoint65d, checkpoint65e, checkpoint65
- Send to coupler the number of coupler time-steps to do for this run:
  this allows to check for consistency and don't need anymore to be
  specified in parameter file "data"
- change the config check to test the agreement of Ocean Depth
  with ATM land/sea mask (instead of ATM orography)
   rename: atmDepthName --> atmLandName and Hatm --> landMask
- check consistency of RunOff map versus Ocean Depth and ATM land/sea mask.

1 jmc 1.1 C $Header: /u/gcmpack/MITgcm/pkg/atm_ocn_coupler/cpl_send_ocn_atmconfig.F,v 1.3 2006/06/15 23:29:17 jmc Exp $
2     C $Name: $
3    
4     #include "CPP_OPTIONS.h"
5    
6     CBOP 0
7     C !ROUTINE: CPL_CHECK_CPLCONFIG
8    
9     C !INTERFACE:
10     SUBROUTINE CPL_CHECK_CPLCONFIG(
11     I msgUnit,
12     U errFlag, errMsg )
13    
14     C !DESCRIPTION:
15     C *==========================================================*
16     C | SUBROUTINE CPL_CHECK_CPLCONFIG
17     C | o Routine to check Coupler config
18     C *==========================================================*
19     C | This routine also set the number of coupler time-step
20     C | to run
21     C *==========================================================*
22    
23     C !USES:
24     IMPLICIT NONE
25     C == Global variables ==
26     #include "ATMSIZE.h"
27     #include "OCNSIZE.h"
28     #include "ATMVARS.h"
29     #include "OCNVARS.h"
30     #include "CPL_PARAMS.h"
31     #include "CPL_MAP2GRIDS.h"
32    
33     C !INPUT/OUTPUT PARAMETERS:
34     C msgUnit :: log-file I/O unit
35     C errFlag :: logical flag to report an error
36     C errMsg :: error message to print
37     INTEGER msgUnit
38     LOGICAL errFlag
39     CHARACTER*(*) errMsg
40    
41     C !LOCAL VARIABLES:
42     INTEGER i, j, n
43     INTEGER ijo, ija
44     LOGICAL tmpVar(Nx_atm,Ny_atm)
45     CEOP
46    
47     C-- Define length of the run (number of coupler time-step)
48     WRITE(msgUnit,'(2A,I9)') ' CPL_CHECK_CPLCONFIG: ',
49     & 'Nb of time-steps to run (ATM) =', nSteps_atm
50     WRITE(msgUnit,'(2A,I9)') ' CPL_CHECK_CPLCONFIG: ',
51     & 'Nb of time-steps to run (OCN) =', nSteps_ocn
52     IF ( nSteps_atm .EQ. nSteps_ocn ) THEN
53     nCouplingSteps = nSteps_ocn
54     WRITE(msgUnit,'(2A,I9)') ' CPL_CHECK_CPLCONFIG: ',
55     & 'Nb of time-steps to run (CPL) =', nCouplingSteps
56     ELSE
57     errFlag = .TRUE.
58     nCouplingSteps = 0
59     WRITE(msgUnit,'(2A)') ' *** ERROR *** CPL_CHECK_CPLCONFIG: ',
60     & ' wrong Nb of time-steps to run'
61     ENDIF
62    
63     C-- Check for consistent RunOff mapping regarding Land/Sea mask:
64     DO j=1,Ny_atm
65     DO i=1,Nx_atm
66     tmpVar(i,j) = landMask_atm(i,j) .EQ. 1. _d 0
67     ENDDO
68     ENDDO
69     DO n=1,nROmap
70     C a) check that RunOff drain a land point
71     ija = ijROatm(n) - 1
72     i = 1 + MOD(ija,Nx_atm)
73     j = 1 + ija/Nx_atm
74     IF ( landMask_atm(i,j).EQ.0. ) THEN
75     errFlag = .TRUE.
76     WRITE(msgUnit,'(A,2I8,A)')
77     & ' *** ERROR *** RunOff Mapp: i,j=', i, j, ' not Land point'
78     ENDIF
79     tmpVar(i,j) = .FALSE.
80     C b) and supply an ocean point
81     ijo = ijROocn(n) - 1
82     i = 1 + MOD(ijo,Nx_ocn)
83     j = 1 + ijo/Nx_ocn
84     IF ( OcMxlD_ocn(i,j).EQ.0. ) THEN
85     errFlag = .TRUE.
86     WRITE(msgUnit,'(A,2I8,A)')
87     & ' *** ERROR *** RunOff Mapp: i,j=', i, j, ' not Oce point'
88     ENDIF
89     ENDDO
90     C c) check that all land-points are drained,
91     C note: would need to know ATM grid-cell area to check that
92     C RunOff Mapping conserve water.
93     DO j=1,Ny_atm
94     DO i=1,Nx_atm
95     IF ( tmpVar(i,j) ) THEN
96     WRITE(msgUnit,'(A,2I8,A)')
97     & ' ** WARNING ** Land point: i,j=', i, j, ' not drained'
98     ENDIF
99     ENDDO
100     ENDDO
101    
102     IF ( errFlag ) THEN
103     errMsg = 'in CPL_CHECK_CPLCONFIG'
104     ELSE
105     WRITE(msgUnit,'(2A)') ' CPL_CHECK_CPLCONFIG: ','done'
106     ENDIF
107    
108     RETURN
109     END

  ViewVC Help