CVS Tags: checkpoint64i, checkpoint64h, checkpoint64j, checkpoint64a, checkpoint64c, checkpoint64b, checkpoint64e, checkpoint64d, checkpoint64g, checkpoint64f, checkpoint63p, checkpoint63q, checkpoint63r, checkpoint63s, checkpoint63l, checkpoint63m, checkpoint63n, checkpoint63o, checkpoint63h, checkpoint63i, checkpoint63j, checkpoint63k, checkpoint63d, checkpoint63e, checkpoint63f, checkpoint63g, checkpoint63a, checkpoint63b, checkpoint63c, checkpoint64, checkpoint63, checkpoint62c, checkpoint62b, checkpoint62a, checkpoint62g, checkpoint62f, checkpoint62e, checkpoint62d, checkpoint62k, checkpoint62j, checkpoint62i, checkpoint62h, checkpoint62o, checkpoint62n, checkpoint62m, checkpoint62l, checkpoint62s, checkpoint62r, checkpoint62q, checkpoint62p, checkpoint62w, checkpoint62v, checkpoint62u, checkpoint62t, checkpoint62z, checkpoint62y, checkpoint62x
Changes since 1.6: +17 -14 lines
fix for multi-threaded

1 C $Header: /u/gcmpack/MITgcm/pkg/aim_compon_interf/cpl_readparms.F,v 1.6 2009/04/28 23:27:24 jmc Exp $
2 C $Name: $
3
4 #include "CPP_OPTIONS.h"
5
6 CBOP
7 C !ROUTINE: CPL_READPARMS
8 C !INTERFACE:
9 SUBROUTINE CPL_READPARMS( myThid )
10
11 C !DESCRIPTION: \bv
12 C *==========================================================*
13 C | S/R CPL_READPARMS
14 C | o Read Coupling parameters that control import/export
15 C | from/to the coupler layer
16 C *==========================================================*
17 C | this version is specific to 1 component (atmos)
18 C *==========================================================*
19 C \ev
20
21 C !USES:
22 IMPLICIT NONE
23
24 C == Global variables ===
25
26 #include "SIZE.h"
27
28 #include "EEPARAMS.h"
29 #include "PARAMS.h"
30 #include "CPL_PARAMS.h"
31 #include "ATMIDS.h"
32
33 C !INPUT/OUTPUT PARAMETERS:
34 C == Routine Arguments ==
35 C myThid :: my Thread Id. number
36 INTEGER myThid
37 CEOP
38
39 #ifdef COMPONENT_MODULE
40
41 C !FUNCTIONS:
42 c INTEGER ILNBLNK
43
44 C !LOCAL VARIABLES:
45 C == Local Variables ==
46 C msgBuf :: Informational/error message buffer
47 C iUnit :: Work variable for IO unit number
48 C k :: loop counter
49 C iL :: Work variable for length of file-name
50 CHARACTER*(MAX_LEN_MBUF) msgBuf
51 INTEGER iUnit
52 c INTEGER k, iL
53 _RL cpl_atmSendFrq
54
55 C---+----1----+----2----+----3----+----4----+----5----+----6----+----7-|--+----|
56
57 C-- Coupling parameters:
58 C cpl_earlyExpImpCall :: call coupler early in the time stepping call sequence
59 C cpl_oldPickup :: restart from an old pickup (= until checkpoint 59h)
60 C useImportMxlD :: True => use Imported Mix.Layer Detph from coupler
61 C useImportSST :: True => use the Imported SST from coupler
62 C useImportSSS :: True => use the Imported SSS from coupler
63 C useImportVsq :: True => use the Imported Surf. velocity^2
64 C useImportFlxCO2 :: True => use the Imported air-sea CO2 fluxes from coupler
65 C cpl_atmSendFrq :: Frequency^-1 for sending data to coupler (s)
66 NAMELIST /CPL_ATM_PARAM/
67 & cpl_earlyExpImpCall,
68 & cpl_oldPickup,
69 & useImportMxlD, useImportSST, useImportSSS,
70 & useImportVsq, useImportFlxCO2,
71 & cpl_atmSendFrq
72
73 C---+----1----+----2----+----3----+----4----+----5----+----6----+----7-|--+----|
74
75 _BEGIN_MASTER(myThid)
76
77 C-- Open the data file
78 WRITE(msgBuf,'(A)') ' CPL_READPARMS: opening data.cpl'
79 CALL PRINT_MESSAGE(msgBuf,standardMessageUnit,SQUEEZE_RIGHT,1)
80
81 CALL OPEN_COPY_DATA_FILE( 'data.cpl', 'CPL_READPARMS',
82 O iUnit, myThid )
83
84 C- Set default value:
85 cpl_earlyExpImpCall = .TRUE.
86 cpl_oldPickup = .FALSE.
87 useImportMxlD = .TRUE.
88 useImportSST = .TRUE.
89 useImportSSS = .TRUE.
90 useImportVsq = .TRUE.
91 IF ( atmCpl_exchange_DIC ) THEN
92 useImportFlxCO2 = .TRUE.
93 ELSE
94 useImportFlxCO2 = .FALSE.
95 ENDIF
96 cpl_atmSendFrq= deltaTClock
97
98 C-- Read parameters from open data file:
99
100 C- Parameters for coupling interface:
101 READ(UNIT=iUnit,NML=CPL_ATM_PARAM)
102
103 WRITE(msgBuf,'(A)')
104 & ' CPL_READPARMS: finished reading data.cpl'
105 CALL PRINT_MESSAGE(msgBuf,standardMessageUnit,SQUEEZE_RIGHT,1)
106
107 C-- Close the open data file
108 CLOSE(iUnit)
109
110 C---+----1----+----2----+----3----+----4----+----5----+----6----+----7-|--+----|
111 C-- Check parameters and model configuration
112 IF ( useImportFlxCO2 .AND. .NOT.atmCpl_exchange_DIC ) THEN
113 WRITE(msgBuf,'(2A)') 'CPL_READPARMS: useImportFlxCO2',
114 & ' requires atmCpl_exchange_DIC TRUE'
115 CALL PRINT_ERROR( msgBuf, myThid)
116 STOP 'ABNORMAL END: S/R CPL_READPARMS'
117 ENDIF
118
119 C- derive other parameters:
120 cplSendFrq_iter = NINT( cpl_atmSendFrq / deltaTClock )
121 IF ( cplSendFrq_iter .LT. 1) cplSendFrq_iter = 1
122
123 C---+----1----+----2----+----3----+----4----+----5----+----6----+----7-|--+----|
124 C-- Print out parameter values :
125
126 iUnit = standardMessageUnit
127 WRITE(msgBuf,'(A)') ' '
128 CALL PRINT_MESSAGE(msgBuf,iUnit,SQUEEZE_RIGHT,1)
129 WRITE(msgBuf,'(A)') '// ==================================='
130 CALL PRINT_MESSAGE(msgBuf,iUnit,SQUEEZE_RIGHT,1)
131 WRITE(msgBuf,'(A)') '// Coupling package parameters :'
132 CALL PRINT_MESSAGE(msgBuf,iUnit,SQUEEZE_RIGHT,1)
133 WRITE(msgBuf,'(A)') '// ==================================='
134 CALL PRINT_MESSAGE(msgBuf,iUnit,SQUEEZE_RIGHT,1)
135
136 C- namelist CPL_ATM_PARAM:
137 CALL WRITE_0D_L( cpl_earlyExpImpCall, INDEX_NONE,
138 & 'cpl_earlyExpImpCall=',
139 & ' /* call coupler early in the time-stepping */')
140 CALL WRITE_0D_L( cpl_oldPickup , INDEX_NONE,
141 & 'cpl_oldPickup =',
142 & ' /* restart from old pickup on/off flag */')
143 CALL WRITE_0D_L( useImportMxlD , INDEX_NONE,
144 & 'useImportMxlD =',
145 & ' /* use Imported MxL. Depth from Coupler flag */')
146 CALL WRITE_0D_L( useImportSST , INDEX_NONE,
147 & 'useImportSST =',
148 & ' /* use Imported SST from Coupler on/off flag */')
149 CALL WRITE_0D_L( useImportSSS , INDEX_NONE,
150 & 'useImportSSS =',
151 & ' /* use Imported SSS from Coupler on/off flag */')
152 CALL WRITE_0D_L( useImportVsq , INDEX_NONE,
153 & 'useImportVsq =',
154 & ' /* use Imported surf.Vel^2 from Coupler flag */')
155 CALL WRITE_0D_L( useImportFlxCO2 , INDEX_NONE,
156 & 'useImportFlxCO2 =',
157 & ' /* use Imported air-sea CO2 flux from Coupler flag */')
158 CALL WRITE_0D_RL( cpl_atmSendFrq, INDEX_NONE, 'cpl_atmSendFrq =',
159 & ' /* Frequency^o-1 for sending data to Coupler (s) */')
160 C cpl_atmSendFrq :: Frequency^-1 for sending data to coupler (s)
161 CALL WRITE_0D_I( cplSendFrq_iter, INDEX_NONE,'cplSendFrq_iter =',
162 &' /* send data to coupler every "cplSendFrq" iter */')
163
164 C---+----1----+----2----+----3----+----4----+----5----+----6----+----7-|--+----|
165
166 _END_MASTER(myThid)
167
168 C-- Everyone else must wait for the parameters to be loaded
169 _BARRIER
170
171 #endif /* COMPONENT_MODULE */
172
173 RETURN
174 END