1 |
C $Header: /u/gcmpack/MITgcm/pkg/atm_compon_interf/atm_cpl_read_pickup.F,v 1.8 2016/01/13 21:36:26 jmc Exp $ |
2 |
C $Name: $ |
3 |
|
4 |
#include "ATM_CPL_OPTIONS.h" |
5 |
|
6 |
CBOP |
7 |
C !ROUTINE: ATM_CPL_READ_PICKUP |
8 |
C !INTERFACE: |
9 |
SUBROUTINE ATM_CPL_READ_PICKUP( myIter, myThid ) |
10 |
|
11 |
C !DESCRIPTION: \bv |
12 |
C *==========================================================* |
13 |
C | SUBROUTINE ATM_CPL_READ_PICKUP |
14 |
C | o Reads fields from a pickup file for a restart |
15 |
C *==========================================================* |
16 |
C *==========================================================* |
17 |
C \ev |
18 |
|
19 |
C !USES: |
20 |
IMPLICIT NONE |
21 |
|
22 |
C == Global variables == |
23 |
#include "SIZE.h" |
24 |
#include "EEPARAMS.h" |
25 |
#include "PARAMS.h" |
26 |
#include "CPL_PARAMS.h" |
27 |
#include "ATMCPL.h" |
28 |
|
29 |
C !INPUT/OUTPUT PARAMETERS: |
30 |
C myIter :: Current time-step number |
31 |
C myThid :: my Thread Id number |
32 |
INTEGER myIter |
33 |
INTEGER myThid |
34 |
|
35 |
#ifdef COMPONENT_MODULE |
36 |
C !LOCAL VARIABLES: |
37 |
C fn :: character buffer for creating filename |
38 |
C fp :: precision of pickup files |
39 |
C filePrec :: pickup-file precision (read from meta file) |
40 |
C nbFields :: number of fields in pickup file (read from meta file) |
41 |
C missFldList :: List of missing fields (attempted to read but not found) |
42 |
C missFldDim :: Dimension of missing fields list array: missFldList |
43 |
C nMissing :: Number of missing fields (attempted to read but not found) |
44 |
C j :: loop index |
45 |
C nj :: record number |
46 |
C ioUnit :: temp for writing msg unit |
47 |
C msgBuf :: Informational/error message buffer |
48 |
INTEGER fp |
49 |
INTEGER filePrec, nbFields |
50 |
INTEGER missFldDim, nMissing |
51 |
INTEGER j, nj, ioUnit |
52 |
PARAMETER( missFldDim = 18 ) |
53 |
CHARACTER*(10) suff |
54 |
CHARACTER*(MAX_LEN_FNAM) fn |
55 |
CHARACTER*(8) missFldList(missFldDim) |
56 |
CHARACTER*(MAX_LEN_MBUF) msgBuf |
57 |
INTEGER i, bi, bj |
58 |
CEOP |
59 |
|
60 |
C---+----1----+----2----+----3----+----4----+----5----+----6----+----7-|--+----| |
61 |
|
62 |
IF ( pickupSuff.EQ.' ' ) THEN |
63 |
IF ( rwSuffixType.EQ.0 ) THEN |
64 |
WRITE(fn,'(A,I10.10)') 'pickup_cpl.', myIter |
65 |
ELSE |
66 |
CALL RW_GET_SUFFIX( suff, startTime, myIter, myThid ) |
67 |
WRITE(fn,'(A,A)') 'pickup_cpl.', suff |
68 |
ENDIF |
69 |
ELSE |
70 |
WRITE(fn,'(A,A10)') 'pickup_cpl.', pickupSuff |
71 |
ENDIF |
72 |
fp = precFloat64 |
73 |
|
74 |
CALL READ_MFLDS_SET( |
75 |
I fn, |
76 |
O nbFields, filePrec, |
77 |
I Nr, myIter, myThid ) |
78 |
_BEGIN_MASTER( myThid ) |
79 |
c IF ( filePrec.NE.0 .AND. filePrec.NE.fp ) THEN |
80 |
IF ( nbFields.GE.0 .AND. filePrec.NE.fp ) THEN |
81 |
WRITE(msgBuf,'(2A,I4)') 'ATM_CPL_READ_PICKUP: ', |
82 |
& 'pickup-file binary precision do not match !' |
83 |
CALL PRINT_ERROR( msgBuf, myThid ) |
84 |
WRITE(msgBuf,'(A,2(A,I4))') 'ATM_CPL_READ_PICKUP: ', |
85 |
& 'file prec.=', filePrec, ' but expecting prec.=', fp |
86 |
CALL PRINT_ERROR( msgBuf, myThid ) |
87 |
CALL ALL_PROC_DIE( 0 ) |
88 |
STOP 'ABNORMAL END: S/R ATM_CPL_READ_PICKUP (data-prec Pb)' |
89 |
ENDIF |
90 |
_END_MASTER( myThid ) |
91 |
|
92 |
IF ( nbFields.LE.0 ) THEN |
93 |
C- No meta-file or old meta-file without List of Fields |
94 |
ioUnit = errorMessageUnit |
95 |
IF ( pickupStrictlyMatch ) THEN |
96 |
WRITE(msgBuf,'(4A)') 'ATM_CPL_READ_PICKUP: ', |
97 |
& 'no field-list found in meta-file', |
98 |
& ' => cannot check for strick-matching' |
99 |
CALL PRINT_ERROR( msgBuf, myThid ) |
100 |
WRITE(msgBuf,'(4A)') 'ATM_CPL_READ_PICKUP: ', |
101 |
& 'try with " pickupStrictlyMatch=.FALSE.,"', |
102 |
& ' in file: "data", NameList: "PARM03"' |
103 |
CALL PRINT_MESSAGE( msgBuf, ioUnit, SQUEEZE_RIGHT, myThid ) |
104 |
CALL ALL_PROC_DIE( myThid ) |
105 |
STOP 'ABNORMAL END: S/R ATM_CPL_READ_PICKUP' |
106 |
ELSE |
107 |
WRITE(msgBuf,'(4A)') 'WARNING >> ATM_CPL_READ_PICKUP: ', |
108 |
& ' no field-list found' |
109 |
CALL PRINT_MESSAGE( msgBuf, ioUnit, SQUEEZE_RIGHT, myThid ) |
110 |
IF ( nbFields.EQ.-1 ) THEN |
111 |
C- No meta-file |
112 |
WRITE(msgBuf,'(4A)') 'WARNING >> ', |
113 |
& ' try to read pickup as currently written' |
114 |
CALL PRINT_MESSAGE( msgBuf, ioUnit, SQUEEZE_RIGHT, myThid ) |
115 |
ELSE |
116 |
C- Old meta-file without List of Fields |
117 |
WRITE(msgBuf,'(4A)') 'WARNING >> ', |
118 |
& ' try to read pickup as it used to be written' |
119 |
CALL PRINT_MESSAGE( msgBuf, ioUnit, SQUEEZE_RIGHT, myThid ) |
120 |
WRITE(msgBuf,'(4A)') 'WARNING >> ', |
121 |
& ' until checkpoint65r (2015 Dec 21)' |
122 |
CALL PRINT_MESSAGE( msgBuf, ioUnit, SQUEEZE_RIGHT, myThid ) |
123 |
c WRITE(msgBuf,'(4A)') 'ATM_CPL_READ_PICKUP: ', |
124 |
c & 'no field-list found in meta-file' |
125 |
c CALL PRINT_ERROR( msgBuf, myThid ) |
126 |
c CALL ALL_PROC_DIE( myThid ) |
127 |
c STOP 'ABNORMAL END: S/R ATM_CPL_READ_PICKUP' |
128 |
ENDIF |
129 |
ENDIF |
130 |
ENDIF |
131 |
|
132 |
C---+----1----+----2----+----3----+----4----+----5----+----6----+----7-|--+----| |
133 |
|
134 |
IF ( nbFields.EQ.0 ) THEN |
135 |
C--- Old way to read pickup: |
136 |
|
137 |
c CALL READ_REC_3D_RL( fn, fp, 1, ocMxlD , 1, myIter,myThid ) |
138 |
c CALL READ_REC_3D_RL( fn, fp, 1, SSTocn , 2, myIter,myThid ) |
139 |
c CALL READ_REC_3D_RL( fn, fp, 1, SSSocn , 3, myIter,myThid ) |
140 |
c CALL READ_REC_3D_RL( fn, fp, 1, vSqocn , 4, myIter,myThid ) |
141 |
c CALL READ_REC_3D_RL( fn, fp, 1, atmSLPr , 5, myIter,myThid ) |
142 |
CALL READ_REC_3D_RL( fn, fp, 1, HeatFlux , 6, myIter,myThid ) |
143 |
CALL READ_REC_3D_RL( fn, fp, 1, qShortWave, 7, myIter,myThid ) |
144 |
CALL READ_REC_3D_RL( fn, fp, 1, tauX , 8, myIter,myThid ) |
145 |
CALL READ_REC_3D_RL( fn, fp, 1, tauY , 9, myIter,myThid ) |
146 |
CALL READ_REC_3D_RL( fn, fp, 1, EvMPrFlux , 10, myIter,myThid ) |
147 |
#ifdef ALLOW_LAND |
148 |
CALL READ_REC_3D_RL( fn, fp, 1, RunOffFlux, 11, myIter,myThid ) |
149 |
CALL READ_REC_3D_RL( fn, fp, 1, RunOffEnFx, 12, myIter,myThid ) |
150 |
#endif /* ALLOW_LAND */ |
151 |
#ifdef ALLOW_THSICE |
152 |
CALL READ_REC_3D_RL( fn, fp, 1, iceSaltFlx, 13, myIter,myThid ) |
153 |
c CALL READ_REC_3D_RL( fn, fp, 1, seaIceMass, 14, myIter,myThid ) |
154 |
#endif /* ALLOW_THSICE */ |
155 |
#ifdef ALLOW_AIM |
156 |
IF ( atm_cplExch_DIC ) THEN |
157 |
c CALL READ_REC_3D_RL( fn,fp, 1, flxCO2ocn , 15, myIter,myThid ) |
158 |
CALL READ_REC_3D_RL( fn,fp, 1, airCO2 , 16, myIter,myThid ) |
159 |
CALL READ_REC_3D_RL( fn,fp, 1, sWSpeed , 17, myIter,myThid ) |
160 |
# ifdef ALLOW_THSICE |
161 |
c CALL READ_REC_3D_RL( fn,fp,1,sIceFrac_cpl, 18, myIter,myThid ) |
162 |
# endif /* ALLOW_THSICE */ |
163 |
ENDIF |
164 |
#endif /* ALLOW_AIM */ |
165 |
|
166 |
ELSE |
167 |
C--- New way to read ATM_CPL pickup: |
168 |
nj = 0 |
169 |
C--- read ATM_CPL 3-D fields for restart |
170 |
nj = nj*Nr |
171 |
|
172 |
C--- read ATM_CPL 2-D fields for restart |
173 |
CALL READ_MFLDS_3D_RL( 'qHeatFlx', HeatFlux, |
174 |
& nj, fp, 1 , myIter, myThid ) |
175 |
CALL READ_MFLDS_3D_RL( 'qShortW ', qShortWave, |
176 |
& nj, fp, 1 , myIter, myThid ) |
177 |
CALL READ_MFLDS_3D_RL( 'surfTauX', tauX, |
178 |
& nj, fp, 1 , myIter, myThid ) |
179 |
CALL READ_MFLDS_3D_RL( 'surfTauY', tauY, |
180 |
& nj, fp, 1 , myIter, myThid ) |
181 |
CALL READ_MFLDS_3D_RL( 'Evp-Prec', EvMPrFlux, |
182 |
& nj, fp, 1 , myIter, myThid ) |
183 |
#ifdef ALLOW_LAND |
184 |
IF ( atm_cplExch_RunOff ) THEN |
185 |
CALL READ_MFLDS_3D_RL('RunOffFx', RunOffFlux, |
186 |
& nj, fp, 1 , myIter, myThid ) |
187 |
CALL READ_MFLDS_3D_RL('RnOfEnFx', RunOffEnFx, |
188 |
& nj, fp, 1 , myIter, myThid ) |
189 |
ENDIF |
190 |
#endif /* ALLOW_LAND */ |
191 |
#ifdef ALLOW_THSICE |
192 |
IF ( atm_cplExch1W_sIce ) THEN |
193 |
CALL READ_MFLDS_3D_RL('saltFlux', iceSaltFlx, |
194 |
& nj, fp, 1 , myIter, myThid ) |
195 |
ENDIF |
196 |
IF ( atm_cplExch_SaltPl ) THEN |
197 |
CALL READ_MFLDS_3D_RL('sltPlmFx', saltPlmFlx_cpl, |
198 |
& nj, fp, 1 , myIter, myThid ) |
199 |
ENDIF |
200 |
#endif /* ALLOW_THSICE */ |
201 |
#ifdef ALLOW_AIM |
202 |
IF ( atm_cplExch_DIC ) THEN |
203 |
CALL READ_MFLDS_3D_RL('atm-CO2 ', airCO2, |
204 |
& nj, fp, 1 , myIter, myThid ) |
205 |
CALL READ_MFLDS_3D_RL('wndSpeed', sWSpeed, |
206 |
& nj, fp, 1 , myIter, myThid ) |
207 |
ENDIF |
208 |
#endif /* ALLOW_AIM */ |
209 |
|
210 |
C-- end: new way to read pickup file |
211 |
ENDIF |
212 |
|
213 |
C-- Check for missing fields: |
214 |
nMissing = missFldDim |
215 |
CALL READ_MFLDS_CHECK( |
216 |
O missFldList, |
217 |
U nMissing, |
218 |
I myIter, myThid ) |
219 |
IF ( nMissing.GT.missFldDim ) THEN |
220 |
WRITE(msgBuf,'(2A,I4)') 'ATM_CPL_READ_PICKUP: ', |
221 |
& 'missing fields list has been truncated to', missFldDim |
222 |
CALL PRINT_ERROR( msgBuf, myThid ) |
223 |
CALL ALL_PROC_DIE( myThid ) |
224 |
STOP 'ABNORMAL END: S/R ATM_CPL_READ_PICKUP (list-size Pb)' |
225 |
ENDIF |
226 |
IF ( nMissing.GE.1 ) THEN |
227 |
ioUnit = errorMessageUnit |
228 |
DO j=1,nMissing |
229 |
WRITE(msgBuf,'(4A)') 'ATM_CPL_READ_PICKUP: ', |
230 |
& 'cannot restart without field "',missFldList(nj),'"' |
231 |
CALL PRINT_ERROR( msgBuf, myThid ) |
232 |
ENDDO |
233 |
CALL ALL_PROC_DIE( myThid ) |
234 |
STOP 'ABNORMAL END: S/R ATM_CPL_READ_PICKUP' |
235 |
ENDIF |
236 |
|
237 |
C-- Update overlap regions: |
238 |
|
239 |
C---+----1----+----2----+----3----+----4----+----5----+----6----+----7-|--+----| |
240 |
|
241 |
IF ( cpl_oldPickup ) THEN |
242 |
_BARRIER |
243 |
C- EmP & RunOff were (before checkpoint59h) in m/s , but are now in kg/m2/s: |
244 |
DO bj = myByLo(myThid), myByHi(myThid) |
245 |
DO bi = myBxLo(myThid), myBxHi(myThid) |
246 |
DO j=1-OLy,sNy+OLy |
247 |
DO i=1-OLx,sNx+OLx |
248 |
EvMPrFlux (i,j,bi,bj) = EvMPrFlux (i,j,bi,bj)*rhoConstFresh |
249 |
#ifdef ALLOW_LAND |
250 |
RunOffFlux(i,j,bi,bj) = RunOffFlux(i,j,bi,bj)*rhoConstFresh |
251 |
#endif /* ALLOW_LAND */ |
252 |
ENDDO |
253 |
ENDDO |
254 |
ENDDO |
255 |
ENDDO |
256 |
ENDIF |
257 |
|
258 |
#endif /* COMPONENT_MODULE */ |
259 |
|
260 |
RETURN |
261 |
END |