16 |
C | This routine help to prevent the use of parameters |
C | This routine help to prevent the use of parameters |
17 |
C | that are not compatible with the model configuration. |
C | that are not compatible with the model configuration. |
18 |
C *=========================================================* |
C *=========================================================* |
19 |
C \ev |
C \ev |
20 |
|
|
21 |
C !USES: |
C !USES: |
22 |
IMPLICIT NONE |
IMPLICIT NONE |
34 |
|
|
35 |
C !LOCAL VARIABLES: |
C !LOCAL VARIABLES: |
36 |
C == Local variables == |
C == Local variables == |
37 |
C msgBuf :: Informational/error meesage buffer |
C msgBuf :: Informational/error message buffer |
38 |
CHARACTER*(MAX_LEN_MBUF) msgBuf |
CHARACTER*(MAX_LEN_MBUF) msgBuf |
39 |
|
INTEGER errCount |
40 |
CEOP |
CEOP |
41 |
|
|
42 |
C- check that CPP option is "defined" when running-flag parameter is on: |
C-- MPI + multi-threads: seems to be OK to let master-thread check & stop |
43 |
|
C (as long as all procs finish cleanly by calling ALL_PROC_DIE) |
44 |
|
_BEGIN_MASTER(myThid) |
45 |
|
errCount = 0 |
46 |
|
|
47 |
#ifndef ALLOW_MNC |
C- check that CPP option is "defined" when running-flag parameter is on: |
|
IF (useMNC) THEN |
|
|
WRITE(msgBuf,'(2A)') '**WARNNING** ', |
|
|
& 'CONFIG_CHECK: useMNC is TRUE and #undef ALLOW_MNC' |
|
|
CALL PRINT_MESSAGE( msgBuf, errorMessageUnit, |
|
|
& SQUEEZE_RIGHT , myThid) |
|
|
ENDIF |
|
|
#endif |
|
48 |
|
|
49 |
#ifndef ALLOW_CD_CODE |
C o If diffKrFile is set, then we should make sure the corresponing |
50 |
IF (useCDscheme) THEN |
C code is being compiled |
51 |
|
#ifndef ALLOW_3D_DIFFKR |
52 |
|
IF (diffKrFile.NE.' ') THEN |
53 |
WRITE(msgBuf,'(A)') |
WRITE(msgBuf,'(A)') |
54 |
& 'CONFIG_CHECK: useCDscheme is TRUE and #undef ALLOW_CD_CODE' |
& 'CONFIG_CHECK: diffKrFile is set but never used.' |
55 |
CALL PRINT_ERROR( msgBuf , myThid) |
CALL PRINT_ERROR( msgBuf, myThid ) |
|
STOP 'ABNORMAL END: S/R CONFIG_CHECK' |
|
|
ENDIF |
|
|
IF (tauCD.NE.0.) THEN |
|
56 |
WRITE(msgBuf,'(A)') |
WRITE(msgBuf,'(A)') |
57 |
& 'CONFIG_CHECK: tauCD has been set but the cd_code package is', |
& 'Re-compile with: #define ALLOW_3D_DIFFKR' |
58 |
& ' enabled' |
CALL PRINT_ERROR( msgBuf, myThid ) |
59 |
CALL PRINT_ERROR( msgBuf , myThid) |
errCount = errCount + 1 |
|
STOP 'ABNORMAL END: S/R CONFIG_CHECK' |
|
60 |
ENDIF |
ENDIF |
61 |
#endif |
#endif |
62 |
|
|
63 |
#ifndef ALLOW_NONHYDROSTATIC |
#ifndef ALLOW_NONHYDROSTATIC |
64 |
IF (nonHydrostatic) THEN |
IF (use3Dsolver) THEN |
|
WRITE(msgBuf,'(A)') |
|
|
& 'CONFIG_CHECK: #undef ALLOW_NONHYDROSTATIC and' |
|
|
CALL PRINT_ERROR( msgBuf , myThid) |
|
65 |
WRITE(msgBuf,'(A)') |
WRITE(msgBuf,'(A)') |
66 |
|
& 'CONFIG_CHECK: #undef ALLOW_NONHYDROSTATIC and' |
67 |
|
CALL PRINT_ERROR( msgBuf, myThid ) |
68 |
|
IF ( implicitIntGravWave ) WRITE(msgBuf,'(A)') |
69 |
|
& 'CONFIG_CHECK: implicitIntGravWave is TRUE' |
70 |
|
IF ( nonHydrostatic ) WRITE(msgBuf,'(A)') |
71 |
& 'CONFIG_CHECK: nonHydrostatic is TRUE' |
& 'CONFIG_CHECK: nonHydrostatic is TRUE' |
72 |
CALL PRINT_ERROR( msgBuf , myThid) |
CALL PRINT_ERROR( msgBuf, myThid ) |
73 |
STOP 'ABNORMAL END: S/R CONFIG_CHECK' |
errCount = errCount + 1 |
74 |
ENDIF |
ENDIF |
75 |
#endif |
#endif |
76 |
|
|
78 |
IF ( alph_AB.NE.UNSET_RL .OR. beta_AB.NE.UNSET_RL ) THEN |
IF ( alph_AB.NE.UNSET_RL .OR. beta_AB.NE.UNSET_RL ) THEN |
79 |
WRITE(msgBuf,'(2A)') 'CONFIG_CHECK: ', |
WRITE(msgBuf,'(2A)') 'CONFIG_CHECK: ', |
80 |
& '#undef ALLOW_ADAMSBASHFORTH_3 but alph_AB,beta_AB' |
& '#undef ALLOW_ADAMSBASHFORTH_3 but alph_AB,beta_AB' |
81 |
CALL PRINT_ERROR( msgBuf , myThid) |
CALL PRINT_ERROR( msgBuf, myThid ) |
82 |
WRITE(msgBuf,'(A,1P2E20.7)') |
WRITE(msgBuf,'(A,1P2E20.7)') |
83 |
& 'CONFIG_CHECK: are set to:',alph_AB,beta_AB |
& 'CONFIG_CHECK: are set to:',alph_AB,beta_AB |
84 |
CALL PRINT_ERROR( msgBuf , myThid) |
CALL PRINT_ERROR( msgBuf, myThid ) |
85 |
STOP 'ABNORMAL END: S/R CONFIG_CHECK' |
errCount = errCount + 1 |
86 |
ENDIF |
ENDIF |
87 |
#endif |
#endif |
88 |
|
|
89 |
#ifndef INCLUDE_IMPLVERTADV_CODE |
#ifndef INCLUDE_IMPLVERTADV_CODE |
90 |
IF ( momImplVertAdv ) THEN |
IF ( momImplVertAdv ) THEN |
91 |
WRITE(msgBuf,'(A)') |
WRITE(msgBuf,'(A)') |
92 |
& 'CONFIG_CHECK: #undef INCLUDE_IMPLVERTADV_CODE' |
& 'CONFIG_CHECK: #undef INCLUDE_IMPLVERTADV_CODE' |
93 |
CALL PRINT_ERROR( msgBuf , myThid) |
CALL PRINT_ERROR( msgBuf, myThid ) |
94 |
WRITE(msgBuf,'(A)') |
WRITE(msgBuf,'(A)') |
95 |
& 'CONFIG_CHECK: but momImplVertAdv is TRUE' |
& 'CONFIG_CHECK: but momImplVertAdv is TRUE' |
96 |
CALL PRINT_ERROR( msgBuf , myThid) |
CALL PRINT_ERROR( msgBuf, myThid ) |
97 |
STOP 'ABNORMAL END: S/R CONFIG_CHECK' |
errCount = errCount + 1 |
98 |
ENDIF |
ENDIF |
99 |
IF ( tempImplVertAdv ) THEN |
IF ( tempImplVertAdv ) THEN |
100 |
WRITE(msgBuf,'(A)') |
WRITE(msgBuf,'(A)') |
101 |
& 'CONFIG_CHECK: #undef INCLUDE_IMPLVERTADV_CODE' |
& 'CONFIG_CHECK: #undef INCLUDE_IMPLVERTADV_CODE' |
102 |
CALL PRINT_ERROR( msgBuf , myThid) |
CALL PRINT_ERROR( msgBuf, myThid ) |
103 |
WRITE(msgBuf,'(A)') |
WRITE(msgBuf,'(A)') |
104 |
& 'CONFIG_CHECK: but tempImplVertAdv is TRUE' |
& 'CONFIG_CHECK: but tempImplVertAdv is TRUE' |
105 |
CALL PRINT_ERROR( msgBuf , myThid) |
CALL PRINT_ERROR( msgBuf, myThid ) |
106 |
STOP 'ABNORMAL END: S/R CONFIG_CHECK' |
errCount = errCount + 1 |
107 |
ENDIF |
ENDIF |
108 |
IF ( saltImplVertAdv ) THEN |
IF ( saltImplVertAdv ) THEN |
109 |
WRITE(msgBuf,'(A)') |
WRITE(msgBuf,'(A)') |
110 |
& 'CONFIG_CHECK: #undef INCLUDE_IMPLVERTADV_CODE' |
& 'CONFIG_CHECK: #undef INCLUDE_IMPLVERTADV_CODE' |
111 |
CALL PRINT_ERROR( msgBuf , myThid) |
CALL PRINT_ERROR( msgBuf, myThid ) |
112 |
WRITE(msgBuf,'(A)') |
WRITE(msgBuf,'(A)') |
113 |
& 'CONFIG_CHECK: but saltImplVertAdv is TRUE' |
& 'CONFIG_CHECK: but saltImplVertAdv is TRUE' |
114 |
CALL PRINT_ERROR( msgBuf , myThid) |
CALL PRINT_ERROR( msgBuf, myThid ) |
115 |
STOP 'ABNORMAL END: S/R CONFIG_CHECK' |
errCount = errCount + 1 |
116 |
ENDIF |
ENDIF |
117 |
IF ( dTtracerLev(1).NE.dTtracerLev(Nr) .AND. implicitDiffusion |
IF ( dTtracerLev(1).NE.dTtracerLev(Nr) .AND. implicitDiffusion |
118 |
& .AND. ( saltStepping .OR. tempStepping .OR. usePTRACERS ) |
& .AND. ( saltStepping .OR. tempStepping .OR. usePTRACERS ) |
119 |
& ) THEN |
& ) THEN |
120 |
WRITE(msgBuf,'(A)') |
WRITE(msgBuf,'(A)') |
121 |
& 'CONFIG_CHECK: #undef INCLUDE_IMPLVERTADV_CODE' |
& 'CONFIG_CHECK: #undef INCLUDE_IMPLVERTADV_CODE' |
122 |
CALL PRINT_ERROR( msgBuf , myThid) |
CALL PRINT_ERROR( msgBuf, myThid ) |
123 |
WRITE(msgBuf,'(2A)') 'CONFIG_CHECK: ', |
WRITE(msgBuf,'(2A)') 'CONFIG_CHECK: ', |
124 |
& 'but implicitDiffusion=T with non-uniform dTtracerLev' |
& 'but implicitDiffusion=T with non-uniform dTtracerLev' |
125 |
CALL PRINT_ERROR( msgBuf , myThid) |
CALL PRINT_ERROR( msgBuf, myThid ) |
126 |
STOP 'ABNORMAL END: S/R CONFIG_CHECK' |
errCount = errCount + 1 |
127 |
|
ENDIF |
128 |
|
#endif |
129 |
|
|
130 |
|
#ifdef ALLOW_AUTODIFF_TAMC |
131 |
|
IF ( momImplVertAdv ) THEN |
132 |
|
WRITE(msgBuf,'(A)') |
133 |
|
& 'CONFIG_CHECK: momImplVertAdv is not yet' |
134 |
|
CALL PRINT_ERROR( msgBuf, myThid ) |
135 |
|
WRITE(msgBuf,'(A)') |
136 |
|
& 'CONFIG_CHECK: supported in adjoint mode' |
137 |
|
CALL PRINT_ERROR( msgBuf, myThid ) |
138 |
|
errCount = errCount + 1 |
139 |
|
ENDIF |
140 |
|
#endif |
141 |
|
|
142 |
|
#ifdef ALLOW_DEPTH_CONTROL |
143 |
|
IF ( useOBCS ) THEN |
144 |
|
WRITE(msgBuf,'(A)') |
145 |
|
& 'CONFIG_CHECK: DEPTH_CONTROL code not compatible with OBCS' |
146 |
|
CALL PRINT_ERROR( msgBuf, myThid ) |
147 |
|
errCount = errCount + 1 |
148 |
ENDIF |
ENDIF |
149 |
#endif |
#endif |
150 |
|
|
151 |
#ifndef EXACT_CONSERV |
#ifndef EXACT_CONSERV |
152 |
IF (exactConserv) THEN |
IF (exactConserv) THEN |
153 |
WRITE(msgBuf,'(A)') |
WRITE(msgBuf,'(A)') |
154 |
& 'CONFIG_CHECK: #undef EXACT_CONSERV and' |
& 'CONFIG_CHECK: #undef EXACT_CONSERV and' |
155 |
CALL PRINT_ERROR( msgBuf , myThid) |
CALL PRINT_ERROR( msgBuf, myThid ) |
156 |
WRITE(msgBuf,'(A)') |
WRITE(msgBuf,'(A)') |
157 |
& 'CONFIG_CHECK: exactConserv is TRUE' |
& 'CONFIG_CHECK: exactConserv is TRUE' |
158 |
CALL PRINT_ERROR( msgBuf , myThid) |
CALL PRINT_ERROR( msgBuf, myThid ) |
159 |
STOP 'ABNORMAL END: S/R CONFIG_CHECK' |
errCount = errCount + 1 |
160 |
ENDIF |
ENDIF |
161 |
#endif |
#endif |
162 |
|
|
163 |
#ifndef NONLIN_FRSURF |
#ifndef NONLIN_FRSURF |
164 |
IF (nonlinFreeSurf.NE.0) THEN |
IF (nonlinFreeSurf.NE.0) THEN |
165 |
WRITE(msgBuf,'(A)') |
WRITE(msgBuf,'(A)') |
166 |
& 'CONFIG_CHECK: #undef NONLIN_FRSURF and' |
& 'CONFIG_CHECK: #undef NONLIN_FRSURF and' |
167 |
CALL PRINT_ERROR( msgBuf , myThid) |
CALL PRINT_ERROR( msgBuf, myThid ) |
168 |
WRITE(msgBuf,'(A)') |
WRITE(msgBuf,'(A)') |
169 |
& 'CONFIG_CHECK: nonlinFreeSurf is non-zero' |
& 'CONFIG_CHECK: nonlinFreeSurf is non-zero' |
170 |
CALL PRINT_ERROR( msgBuf , myThid) |
CALL PRINT_ERROR( msgBuf, myThid ) |
171 |
STOP 'ABNORMAL END: S/R CONFIG_CHECK' |
errCount = errCount + 1 |
172 |
ENDIF |
ENDIF |
173 |
#endif |
#endif |
174 |
|
|
175 |
#ifndef NONLIN_FRSURF |
#ifndef NONLIN_FRSURF |
176 |
IF (select_rStar .NE. 0) THEN |
IF (select_rStar .NE. 0) THEN |
177 |
WRITE(msgBuf,'(A)') |
WRITE(msgBuf,'(A)') |
178 |
& 'CONFIG_CHECK: rStar is part of NonLin-FS ' |
& 'CONFIG_CHECK: rStar is part of NonLin-FS ' |
179 |
CALL PRINT_ERROR( msgBuf, myThid) |
CALL PRINT_ERROR( msgBuf, myThid ) |
180 |
WRITE(msgBuf,'(A)') |
WRITE(msgBuf,'(A)') |
181 |
& 'CONFIG_CHECK: ==> use #define NONLIN_FRSURF to use it' |
& 'CONFIG_CHECK: ==> set #define NONLIN_FRSURF to use it' |
182 |
CALL PRINT_ERROR( msgBuf, myThid) |
CALL PRINT_ERROR( msgBuf, myThid ) |
183 |
STOP 'ABNORMAL END: S/R CONFIG_CHECK' |
errCount = errCount + 1 |
184 |
ENDIF |
ENDIF |
185 |
#endif /* NONLIN_FRSURF */ |
#endif /* NONLIN_FRSURF */ |
186 |
|
|
187 |
|
#ifdef DISABLE_RSTAR_CODE |
188 |
|
IF ( select_rStar.NE.0 ) THEN |
189 |
|
WRITE(msgBuf,'(A)') |
190 |
|
& 'CONFIG_CHECK: rStar code disable (DISABLE_RSTAR_CODE defined)' |
191 |
|
CALL PRINT_ERROR( msgBuf, myThid ) |
192 |
|
WRITE(msgBuf,'(A)') |
193 |
|
& 'CONFIG_CHECK: ==> set #undef DISABLE_RSTAR_CODE to use it' |
194 |
|
CALL PRINT_ERROR( msgBuf, myThid ) |
195 |
|
errCount = errCount + 1 |
196 |
|
ENDIF |
197 |
|
#endif /* DISABLE_RSTAR_CODE */ |
198 |
|
|
199 |
|
#ifdef DISABLE_SIGMA_CODE |
200 |
|
IF ( selectSigmaCoord.NE.0 ) THEN |
201 |
|
WRITE(msgBuf,'(A)') |
202 |
|
& 'CONFIG_CHECK: Sigma code disable (DISABLE_SIGMA_CODE defined)' |
203 |
|
CALL PRINT_ERROR( msgBuf, myThid ) |
204 |
|
WRITE(msgBuf,'(A)') |
205 |
|
& 'CONFIG_CHECK: ==> set #undef DISABLE_SIGMA_CODE to use it' |
206 |
|
CALL PRINT_ERROR( msgBuf, myThid ) |
207 |
|
errCount = errCount + 1 |
208 |
|
ENDIF |
209 |
|
#endif /* DISABLE_SIGMA_CODE */ |
210 |
|
|
211 |
#ifdef USE_NATURAL_BCS |
#ifdef USE_NATURAL_BCS |
212 |
WRITE(msgBuf,'(A)') |
WRITE(msgBuf,'(A)') |
213 |
& 'CONFIG_CHECK: USE_NATURAL_BCS option has been replaced' |
& 'CONFIG_CHECK: USE_NATURAL_BCS option has been replaced' |
214 |
CALL PRINT_ERROR( msgBuf , myThid) |
CALL PRINT_ERROR( msgBuf, myThid ) |
215 |
WRITE(msgBuf,'(A)') |
WRITE(msgBuf,'(A)') |
216 |
& 'CONFIG_CHECK: by useRealFreshWaterFlux=TRUE in data file' |
& 'CONFIG_CHECK: by useRealFreshWaterFlux=TRUE in data file' |
217 |
CALL PRINT_ERROR( msgBuf , myThid) |
CALL PRINT_ERROR( msgBuf, myThid ) |
218 |
STOP 'ABNORMAL END: S/R CONFIG_CHECK' |
errCount = errCount + 1 |
219 |
#endif |
#endif |
220 |
|
|
221 |
|
#ifndef ALLOW_ADDFLUID |
222 |
|
IF ( selectAddFluid.NE.0 ) THEN |
223 |
|
WRITE(msgBuf,'(A)') |
224 |
|
& 'CONFIG_CHECK: #undef ALLOW_ADDFLUID and' |
225 |
|
CALL PRINT_ERROR( msgBuf, myThid ) |
226 |
|
WRITE(msgBuf,'(A,I4,A)') 'CONFIG_CHECK: selectAddFluid=', |
227 |
|
& selectAddFluid, ' is not zero' |
228 |
|
CALL PRINT_ERROR( msgBuf, myThid ) |
229 |
|
errCount = errCount + 1 |
230 |
|
ENDIF |
231 |
|
#endif /* ALLOW_ADDFLUID */ |
232 |
|
|
233 |
C o If pLoadFile is set, then we should make sure the corresponing |
C o If pLoadFile is set, then we should make sure the corresponing |
234 |
C code is being compiled |
C code is being compiled |
235 |
#ifndef ATMOSPHERIC_LOADING |
#ifndef ATMOSPHERIC_LOADING |
236 |
IF (pLoadFile.NE.' ') THEN |
IF (pLoadFile.NE.' ') THEN |
237 |
WRITE(msgBuf,'(A)') |
WRITE(msgBuf,'(A)') |
238 |
& 'CONFIG_CHECK: pLoadFile is set but you have not' |
& 'CONFIG_CHECK: pLoadFile is set but you have not' |
239 |
CALL PRINT_ERROR( msgBuf , myThid) |
CALL PRINT_ERROR( msgBuf, myThid ) |
240 |
WRITE(msgBuf,'(A)') |
WRITE(msgBuf,'(A)') |
241 |
& 'compiled the model with the pressure loading code.' |
& 'compiled the model with the pressure loading code.' |
242 |
CALL PRINT_ERROR( msgBuf , myThid) |
CALL PRINT_ERROR( msgBuf, myThid ) |
243 |
WRITE(msgBuf,'(A)') |
WRITE(msgBuf,'(A)') |
244 |
& 'Re-compile with: #define ATMOSPHERIC_LOADING' |
& 'Re-compile with: #define ATMOSPHERIC_LOADING' |
245 |
CALL PRINT_ERROR( msgBuf , myThid) |
CALL PRINT_ERROR( msgBuf, myThid ) |
246 |
STOP 'ABNORMAL END: S/R CONFIG_CHECK' |
errCount = errCount + 1 |
247 |
ENDIF |
ENDIF |
248 |
IF ( useRealFreshWaterFlux .AND. useThSIce ) THEN |
IF ( useRealFreshWaterFlux .AND. useThSIce ) THEN |
249 |
WRITE(msgBuf,'(A)') |
WRITE(msgBuf,'(A)') |
250 |
& 'CONFIG_CHECK: sIceLoad is computed but' |
& 'CONFIG_CHECK: sIceLoad is computed but' |
251 |
CALL PRINT_ERROR( msgBuf , myThid) |
CALL PRINT_ERROR( msgBuf, myThid ) |
252 |
WRITE(msgBuf,'(A)') |
WRITE(msgBuf,'(A)') |
253 |
& 'pressure loading code is not compiled.' |
& 'pressure loading code is not compiled.' |
254 |
CALL PRINT_ERROR( msgBuf , myThid) |
CALL PRINT_ERROR( msgBuf, myThid ) |
255 |
WRITE(msgBuf,'(A)') |
WRITE(msgBuf,'(A)') |
256 |
& 'Re-compile with: #define ATMOSPHERIC_LOADING' |
& 'Re-compile with: #define ATMOSPHERIC_LOADING' |
257 |
CALL PRINT_ERROR( msgBuf , myThid) |
CALL PRINT_ERROR( msgBuf, myThid ) |
258 |
STOP 'ABNORMAL END: S/R CONFIG_CHECK' |
errCount = errCount + 1 |
|
ENDIF |
|
|
#endif |
|
|
|
|
|
#ifndef ALLOW_GENERIC_ADVDIFF |
|
|
IF ( tempStepping .OR. saltStepping ) THEN |
|
|
WRITE(msgBuf,'(2A)') |
|
|
& 'CONFIG_CHECK: cannot step forward Temp or Salt', |
|
|
& ' without pkg/generic_advdiff' |
|
|
CALL PRINT_ERROR( msgBuf , 1) |
|
|
WRITE(msgBuf,'(A)') |
|
|
& 'Re-compile with pkg "generic_advdiff" in packages.conf' |
|
|
CALL PRINT_ERROR( msgBuf , 1) |
|
|
STOP 'ABNORMAL END: S/R CONFIG_CHECK' |
|
259 |
ENDIF |
ENDIF |
260 |
#endif |
#endif |
261 |
|
|
262 |
C o If taveFreq is finite, then we must make sure the diagnostics |
#ifndef ALLOW_BALANCE_FLUXES |
263 |
C code is being compiled |
IF (balanceEmPmR .OR. balanceQnet) THEN |
264 |
#ifndef ALLOW_TIMEAVE |
WRITE(msgBuf,'(A,A)') |
265 |
IF (taveFreq.NE.0.) THEN |
& 'CONFIG_CHECK: balanceEmPmR/Qnet is set but balance code ', |
266 |
WRITE(msgBuf,'(A)') |
& 'is not compiled.' |
267 |
& 'CONFIG_CHECK: taveFreq <> 0 but pkg/timeave is not compiled' |
CALL PRINT_ERROR( msgBuf, myThid ) |
|
CALL PRINT_ERROR( msgBuf , 1) |
|
268 |
WRITE(msgBuf,'(A)') |
WRITE(msgBuf,'(A)') |
269 |
& 'Re-compile with pkg "timeave" in packages.conf' |
& 'Re-compile with ALLOW_BALANCE_FLUXES defined' |
270 |
CALL PRINT_ERROR( msgBuf , 1) |
CALL PRINT_ERROR( msgBuf, myThid ) |
271 |
STOP 'ABNORMAL END: S/R CONFIG_CHECK' |
errCount = errCount + 1 |
272 |
ENDIF |
ENDIF |
273 |
#endif |
#endif |
274 |
|
|
275 |
C o If calendarDumps is set, pkg/cal is required |
#ifndef ALLOW_BALANCE_RELAX |
276 |
#ifndef ALLOW_CAL |
IF (balanceThetaClimRelax .OR. balanceSaltClimRelax) THEN |
277 |
IF (calendarDumps) THEN |
WRITE(msgBuf,'(A,A)') |
278 |
WRITE(msgBuf,'(A)') |
& 'CONFIG_CHECK: balanceTheta/SaltClimRelax is set ', |
279 |
& 'CONFIG_CHECK: calendarDumps is set but pkg/cal is not compiled' |
& 'but balance code is not compiled.' |
280 |
CALL PRINT_ERROR( msgBuf , 1) |
CALL PRINT_ERROR( msgBuf, myThid ) |
281 |
WRITE(msgBuf,'(A)') |
WRITE(msgBuf,'(A)') |
282 |
& 'Re-compile with pkg "cal" in packages.conf' |
& 'Re-compile with ALLOW_BALANCE_RELAX defined' |
283 |
CALL PRINT_ERROR( msgBuf , 1) |
CALL PRINT_ERROR( msgBuf, myThid ) |
284 |
STOP 'ABNORMAL END: S/R CONFIG_CHECK' |
errCount = errCount + 1 |
285 |
ENDIF |
ENDIF |
286 |
#endif |
#endif |
287 |
|
|
288 |
#ifndef ALLOW_MATRIX |
#ifndef ALLOW_SRCG |
289 |
IF (useMATRIX) THEN |
IF (useSRCGSolver) THEN |
290 |
WRITE(msgBuf,'(A)') |
WRITE(msgBuf,'(A,A)') |
291 |
& 'CONFIG_CHECK: useMATRIX is TRUE and #undef ALLOW_MATRIX' |
& 'CONFIG_CHECK: useSRCGSolver = .TRUE., but single reduction ', |
292 |
CALL PRINT_ERROR( msgBuf , myThid) |
& 'code is not compiled.' |
293 |
STOP 'ABNORMAL END: S/R CONFIG_CHECK' |
CALL PRINT_ERROR( msgBuf, myThid ) |
294 |
|
WRITE(msgBuf,'(A)') |
295 |
|
& 'CONFIG_CHECK: Re-compile with ALLOW_SRCG defined' |
296 |
|
CALL PRINT_ERROR( msgBuf, myThid ) |
297 |
|
errCount = errCount + 1 |
298 |
ENDIF |
ENDIF |
299 |
#endif |
#endif /* ALLOW_SRCG */ |
300 |
|
|
301 |
C---+----1----+----2----+----3----+----4----+----5----+----6----+----7-|--+----| |
C---+----1----+----2----+----3----+----4----+----5----+----6----+----7-|--+----| |
302 |
|
|
303 |
C- check parameter consistency : |
C-- Check parameter consistency : |
304 |
|
|
305 |
IF ( ( Olx.LT.3 .OR. Oly.LT.3 ) .AND. |
IF ( ( OLx.LT.3 .OR. OLy.LT.3 ) .AND. |
306 |
& ( viscC4leith.NE.0. .OR. viscA4Grid.NE.0. |
& ( viscC4leithD.NE.0. .OR. viscC4leith.NE.0. |
307 |
& .OR. viscA4D.NE.0. .OR. viscA4Z.NE.0. ) ) THEN |
& .OR. viscC4smag.NE.0. .OR. viscA4Grid.NE.0. |
308 |
|
& .OR. viscA4D.NE.0. .OR. viscA4Z.NE.0. ) ) THEN |
309 |
WRITE(msgBuf,'(A,A)') |
WRITE(msgBuf,'(A,A)') |
310 |
& 'CONFIG_CHECK: cannot use Biharmonic Visc. (viscA4) with', |
& 'CONFIG_CHECK: cannot use Biharmonic Visc. (viscA4) with', |
311 |
& ' overlap (Olx,Oly) smaller than 3' |
& ' overlap (OLx,OLy) smaller than 3' |
312 |
CALL PRINT_ERROR( msgBuf , myThid) |
CALL PRINT_ERROR( msgBuf, myThid ) |
313 |
STOP 'ABNORMAL END: S/R CONFIG_CHECK' |
errCount = errCount + 1 |
314 |
ENDIF |
ENDIF |
315 |
|
IF ( ( OLx.LT.3 .OR. OLy.LT.3 ) .AND. |
316 |
|
& ( viscC2leithD.NE.0. .OR. viscC4leithD.NE.0. ) |
317 |
|
& ) THEN |
318 |
|
WRITE(msgBuf,'(A,A)') |
319 |
|
& 'CONFIG_CHECK: cannot use Leith Visc.(div.part) with', |
320 |
|
& ' overlap (OLx,OLy) smaller than 3' |
321 |
|
CALL PRINT_ERROR( msgBuf, myThid ) |
322 |
|
errCount = errCount + 1 |
323 |
|
ENDIF |
324 |
|
|
325 |
|
#ifndef DISCONNECTED_TILES |
326 |
|
C Overlaps cannot be larger than interior tile except for special cases |
327 |
|
IF ( sNx.LT.OLx ) THEN |
328 |
|
#ifdef ALLOW_EXCH2 |
329 |
|
WRITE(msgBuf,'(A)') |
330 |
|
& 'CONFIG_CHECK: sNx<OLx not allowed with ALLOW_EXCH2 defined' |
331 |
|
CALL PRINT_ERROR( msgBuf, myThid ) |
332 |
|
errCount = errCount + 1 |
333 |
|
#endif /* ALLOW_EXCH2 */ |
334 |
|
IF ( Nx.NE.1 ) THEN |
335 |
|
WRITE(msgBuf,'(A)') |
336 |
|
& 'CONFIG_CHECK: sNx<OLx not allowed unless Nx=1' |
337 |
|
CALL PRINT_ERROR( msgBuf, myThid ) |
338 |
|
errCount = errCount + 1 |
339 |
|
ENDIF |
340 |
|
ENDIF |
341 |
|
IF ( sNy.LT.OLy ) THEN |
342 |
|
#ifdef ALLOW_EXCH2 |
343 |
|
WRITE(msgBuf,'(A)') |
344 |
|
& 'CONFIG_CHECK: sNy<OLy not allowed with ALLOW_EXCH2 defined' |
345 |
|
CALL PRINT_ERROR( msgBuf, myThid ) |
346 |
|
errCount = errCount + 1 |
347 |
|
#endif /* ALLOW_EXCH2 */ |
348 |
|
IF ( Ny.NE.1 ) THEN |
349 |
|
WRITE(msgBuf,'(A)') |
350 |
|
& 'CONFIG_CHECK: sNy<OLy not allowed unless Ny=1' |
351 |
|
CALL PRINT_ERROR( msgBuf, myThid ) |
352 |
|
errCount = errCount + 1 |
353 |
|
ENDIF |
354 |
|
ENDIF |
355 |
|
#endif /* ndef DISCONNECTED_TILES */ |
356 |
|
|
357 |
|
C-- Deep-Atmosphere & Anelastic limitations: |
358 |
|
IF ( deepAtmosphere .AND. |
359 |
|
& useRealFreshWaterFlux .AND. usingPCoords ) THEN |
360 |
|
WRITE(msgBuf,'(A,A)') |
361 |
|
& 'CONFIG_CHECK: Deep-Atmosphere not yet implemented with', |
362 |
|
& ' real-Fresh-Water option in P-coordinate' |
363 |
|
CALL PRINT_ERROR( msgBuf, myThid ) |
364 |
|
errCount = errCount + 1 |
365 |
|
ENDIF |
366 |
|
IF ( select_rStar.NE.0 .AND. |
367 |
|
& ( deepAtmosphere .OR. |
368 |
|
& usingZCoords.AND.rhoRefFile .NE. ' ' ) ) THEN |
369 |
|
WRITE(msgBuf,'(A,A)') |
370 |
|
& 'CONFIG_CHECK: Deep-Atmosphere or Anelastic', |
371 |
|
& ' not yet implemented with rStar' |
372 |
|
CALL PRINT_ERROR( msgBuf, myThid ) |
373 |
|
errCount = errCount + 1 |
374 |
|
ENDIF |
375 |
|
IF ( vectorInvariantMomentum .AND. |
376 |
|
& ( deepAtmosphere .OR. |
377 |
|
& usingZCoords.AND.rhoRefFile .NE. ' ' ) ) THEN |
378 |
|
WRITE(msgBuf,'(A,A)') |
379 |
|
& 'CONFIG_CHECK: Deep-Atmosphere or Anelastic', |
380 |
|
& ' not yet implemented in Vector-Invariant momentum code' |
381 |
|
CALL PRINT_ERROR( msgBuf, myThid ) |
382 |
|
errCount = errCount + 1 |
383 |
|
ENDIF |
384 |
|
|
385 |
|
C-- Free-surface related limitations: |
386 |
IF ( rigidLid .AND. implicitFreeSurface ) THEN |
IF ( rigidLid .AND. implicitFreeSurface ) THEN |
387 |
WRITE(msgBuf,'(A,A)') |
WRITE(msgBuf,'(A,A)') |
388 |
& 'CONFIG_CHECK: Cannot select both implicitFreeSurface', |
& 'CONFIG_CHECK: Cannot select both implicitFreeSurface', |
389 |
& ' and rigidLid.' |
& ' and rigidLid.' |
390 |
CALL PRINT_ERROR( msgBuf , myThid) |
CALL PRINT_ERROR( msgBuf, myThid ) |
391 |
STOP 'ABNORMAL END: S/R CONFIG_CHECK' |
errCount = errCount + 1 |
392 |
ENDIF |
ENDIF |
393 |
|
|
394 |
IF (rigidLid .AND. exactConserv) THEN |
IF (rigidLid .AND. exactConserv) THEN |
395 |
WRITE(msgBuf,'(A)') |
WRITE(msgBuf,'(A)') |
396 |
& 'CONFIG_CHECK: exactConserv not compatible with' |
& 'CONFIG_CHECK: exactConserv not compatible with' |
397 |
CALL PRINT_ERROR( msgBuf , myThid) |
CALL PRINT_ERROR( msgBuf, myThid ) |
398 |
WRITE(msgBuf,'(A)') |
WRITE(msgBuf,'(A)') |
399 |
& 'CONFIG_CHECK: rigidLid (meaningless in that case)' |
& 'CONFIG_CHECK: rigidLid (meaningless in that case)' |
400 |
CALL PRINT_ERROR( msgBuf , myThid) |
CALL PRINT_ERROR( msgBuf, myThid ) |
401 |
STOP 'ABNORMAL END: S/R CONFIG_CHECK' |
errCount = errCount + 1 |
402 |
|
ENDIF |
403 |
|
|
404 |
|
IF ( linFSConserveTr .AND. nonlinFreeSurf.NE.0 ) THEN |
405 |
|
WRITE(msgBuf,'(A)') |
406 |
|
& 'CONFIG_CHECK: Cannot select both a Nonlinear Free Surf.' |
407 |
|
CALL PRINT_ERROR( msgBuf, myThid ) |
408 |
|
WRITE(msgBuf,'(A)') |
409 |
|
& 'CONFIG_CHECK: and Tracer Correction of Lin. Free Surf.' |
410 |
|
CALL PRINT_ERROR( msgBuf, myThid ) |
411 |
|
errCount = errCount + 1 |
412 |
ENDIF |
ENDIF |
413 |
|
|
414 |
IF (rigidLid .AND. useRealFreshWaterFlux) THEN |
IF (rigidLid .AND. useRealFreshWaterFlux) THEN |
415 |
WRITE(msgBuf,'(A)') |
WRITE(msgBuf,'(A)') |
416 |
& 'CONFIG_CHECK: useRealFreshWaterFlux not compatible with' |
& 'CONFIG_CHECK: useRealFreshWaterFlux not compatible with' |
417 |
CALL PRINT_ERROR( msgBuf , myThid) |
CALL PRINT_ERROR( msgBuf, myThid ) |
418 |
WRITE(msgBuf,'(A)') |
WRITE(msgBuf,'(A)') |
419 |
& 'CONFIG_CHECK: rigidLid (meaningless in that case)' |
& 'CONFIG_CHECK: rigidLid (meaningless in that case)' |
420 |
CALL PRINT_ERROR( msgBuf , myThid) |
CALL PRINT_ERROR( msgBuf, myThid ) |
421 |
STOP 'ABNORMAL END: S/R CONFIG_CHECK' |
errCount = errCount + 1 |
|
ENDIF |
|
|
|
|
|
IF ( (implicSurfPress.NE.1. .OR. implicDiv2DFlow.NE.1.) |
|
|
& .AND. nonHydrostatic ) THEN |
|
|
WRITE(msgBuf,'(A,A)') 'CONFIG_CHECK: nonHydrostatic', |
|
|
& ' NOT SAFE with non-fully implicit Barotropic solver' |
|
|
CALL PRINT_ERROR( msgBuf , myThid) |
|
|
WRITE(msgBuf,'(A,A)') 'CONFIG_CHECK: To by-pass this', |
|
|
& 'STOP, comment this test and re-compile config_check' |
|
|
CALL PRINT_ERROR( msgBuf , myThid) |
|
|
STOP 'ABNORMAL END: S/R CONFIG_CHECK' |
|
422 |
ENDIF |
ENDIF |
423 |
|
|
424 |
IF (nonlinFreeSurf.NE.0 .AND. .NOT.exactConserv) THEN |
IF (nonlinFreeSurf.NE.0 .AND. .NOT.exactConserv) THEN |
425 |
WRITE(msgBuf,'(A)') |
WRITE(msgBuf,'(A)') |
426 |
& 'CONFIG_CHECK: nonlinFreeSurf cannot be used' |
& 'CONFIG_CHECK: nonlinFreeSurf cannot be used' |
427 |
CALL PRINT_ERROR( msgBuf , myThid) |
CALL PRINT_ERROR( msgBuf, myThid ) |
428 |
WRITE(msgBuf,'(A)') |
WRITE(msgBuf,'(A)') |
429 |
& 'CONFIG_CHECK: without exactConserv' |
& 'CONFIG_CHECK: without exactConserv' |
430 |
CALL PRINT_ERROR( msgBuf , myThid) |
CALL PRINT_ERROR( msgBuf, myThid ) |
431 |
STOP 'ABNORMAL END: S/R CONFIG_CHECK' |
errCount = errCount + 1 |
432 |
ENDIF |
ENDIF |
433 |
|
|
434 |
IF (select_rStar.NE.0 .AND. .NOT.exactConserv) THEN |
IF (select_rStar.NE.0 .AND. .NOT.exactConserv) THEN |
435 |
WRITE(msgBuf,'(A)') |
WRITE(msgBuf,'(A)') |
436 |
& 'CONFIG_CHECK: r* Coordinate cannot be used' |
& 'CONFIG_CHECK: r* Coordinate cannot be used' |
437 |
CALL PRINT_ERROR( msgBuf , myThid) |
CALL PRINT_ERROR( msgBuf, myThid ) |
438 |
WRITE(msgBuf,'(A)') |
WRITE(msgBuf,'(A)') |
439 |
& 'CONFIG_CHECK: without exactConserv' |
& 'CONFIG_CHECK: without exactConserv' |
440 |
CALL PRINT_ERROR( msgBuf , myThid) |
CALL PRINT_ERROR( msgBuf, myThid ) |
441 |
STOP 'ABNORMAL END: S/R CONFIG_CHECK' |
errCount = errCount + 1 |
442 |
ENDIF |
ENDIF |
443 |
|
|
444 |
C- note : not implemented in checkpoint48b but it's done now (since 01-28-03) |
IF ( select_rStar.GE.1 .AND. nonlinFreeSurf.LE.0 ) THEN |
445 |
|
WRITE(msgBuf,'(2A,I3,A)') 'CONFIG_CHECK: r* Coordinate', |
446 |
|
& ' (select_rStar=', select_rStar, ' ) cannot be used' |
447 |
|
CALL PRINT_ERROR( msgBuf, myThid ) |
448 |
|
WRITE(msgBuf,'(2A,I3,A)') 'CONFIG_CHECK: ', |
449 |
|
& ' with Linear FreeSurf (nonlinFreeSurf=', nonlinFreeSurf,' )' |
450 |
|
CALL PRINT_ERROR( msgBuf, myThid ) |
451 |
|
errCount = errCount + 1 |
452 |
|
ENDIF |
453 |
|
|
454 |
|
IF ( selectSigmaCoord.NE.0 ) THEN |
455 |
|
IF ( fluidIsWater ) THEN |
456 |
|
WRITE(msgBuf,'(A)') |
457 |
|
& 'CONFIG_CHECK: Sigma-Coords not yet coded for Oceanic set-up' |
458 |
|
CALL PRINT_ERROR( msgBuf, myThid ) |
459 |
|
errCount = errCount + 1 |
460 |
|
ENDIF |
461 |
|
IF ( nonlinFreeSurf.LE.0 ) THEN |
462 |
|
WRITE(msgBuf,'(A)') |
463 |
|
& 'CONFIG_CHECK: Sigma-Coords not coded for Lin-FreeSurf' |
464 |
|
CALL PRINT_ERROR( msgBuf, myThid ) |
465 |
|
errCount = errCount + 1 |
466 |
|
ENDIF |
467 |
|
IF (select_rStar.NE.0 ) THEN |
468 |
|
WRITE(msgBuf,'(A)') |
469 |
|
& 'CONFIG_CHECK: Sigma-Coords and rStar are not compatible' |
470 |
|
CALL PRINT_ERROR( msgBuf, myThid ) |
471 |
|
errCount = errCount + 1 |
472 |
|
ENDIF |
473 |
|
WRITE(msgBuf,'(A)') |
474 |
|
& 'CONFIG_CHECK: Sigma-Coords code neither complete nor tested' |
475 |
|
CALL PRINT_MESSAGE( msgBuf, errorMessageUnit, |
476 |
|
& SQUEEZE_RIGHT, myThid ) |
477 |
|
ENDIF |
478 |
|
|
479 |
|
C- note : not implemented in checkpoint48b but it is done now (since 01-28-03) |
480 |
c IF (select_rStar.GT.0 .AND. useOBCS ) THEN |
c IF (select_rStar.GT.0 .AND. useOBCS ) THEN |
|
c WRITE(msgBuf,'(A)') |
|
|
c & 'CONFIG_CHECK: r* Coordinate not yet implemented' |
|
|
c CALL PRINT_ERROR( msgBuf , 1) |
|
|
c WRITE(msgBuf,'(A)') |
|
|
c & 'CONFIG_CHECK: in OBC package' |
|
|
c CALL PRINT_ERROR( msgBuf , 1) |
|
481 |
c STOP 'ABNORMAL END: S/R CONFIG_CHECK' |
c STOP 'ABNORMAL END: S/R CONFIG_CHECK' |
482 |
c ENDIF |
c ENDIF |
483 |
|
|
484 |
IF (nonlinFreeSurf.NE.0 .AND. nonHydrostatic) THEN |
IF ( nonlinFreeSurf.NE.0 .AND. |
|
WRITE(msgBuf,'(A)') |
|
|
& 'CONFIG_CHECK: nonlinFreeSurf not yet implemented' |
|
|
CALL PRINT_ERROR( msgBuf , myThid) |
|
|
WRITE(msgBuf,'(A)') |
|
|
& 'CONFIG_CHECK: in nonHydrostatic code' |
|
|
CALL PRINT_ERROR( msgBuf , myThid) |
|
|
STOP 'ABNORMAL END: S/R CONFIG_CHECK' |
|
|
ENDIF |
|
|
|
|
|
IF ( nonlinFreeSurf.NE.0 .AND. |
|
485 |
& deltaTfreesurf.NE.dTtracerLev(1) ) THEN |
& deltaTfreesurf.NE.dTtracerLev(1) ) THEN |
486 |
WRITE(msgBuf,'(A)') |
WRITE(msgBuf,'(2A)') '** WARNING ** CONFIG_CHECK: ', |
487 |
& 'CONFIG_CHECK: WARNING: nonlinFreeSurf might cause problems' |
& 'nonlinFreeSurf might cause problems' |
488 |
CALL PRINT_MESSAGE( msgBuf, errorMessageUnit, |
CALL PRINT_MESSAGE( msgBuf, errorMessageUnit, |
489 |
& SQUEEZE_RIGHT , myThid) |
& SQUEEZE_RIGHT, myThid ) |
490 |
WRITE(msgBuf,'(A)') |
WRITE(msgBuf,'(2A)') '** WARNING ** ', |
491 |
& 'CONFIG_CHECK: with different FreeSurf & Tracer time-steps' |
& 'with different FreeSurf & Tracer time-steps' |
492 |
CALL PRINT_MESSAGE( msgBuf, errorMessageUnit, |
CALL PRINT_MESSAGE( msgBuf, errorMessageUnit, |
493 |
& SQUEEZE_RIGHT , myThid) |
& SQUEEZE_RIGHT, myThid ) |
494 |
ENDIF |
ENDIF |
495 |
|
|
496 |
IF ( useRealFreshWaterFlux .AND. exactConserv |
IF ( useRealFreshWaterFlux .AND. exactConserv |
497 |
& .AND. implicDiv2DFlow.EQ.0. _d 0 |
& .AND. implicDiv2Dflow.EQ.0. _d 0 |
498 |
& .AND. startTime.NE.baseTime .AND. usePickupBeforeC54 ) THEN |
& .AND. startTime.NE.baseTime .AND. usePickupBeforeC54 ) THEN |
499 |
WRITE(msgBuf,'(A)') |
WRITE(msgBuf,'(A)') |
500 |
& 'CONFIG_CHECK: RealFreshWaterFlux+implicSurfP=0+exactConserv:' |
& 'CONFIG_CHECK: RealFreshWaterFlux+implicSurfP=0+exactConserv:' |
501 |
CALL PRINT_ERROR( msgBuf , myThid) |
CALL PRINT_ERROR( msgBuf, myThid ) |
502 |
WRITE(msgBuf,'(A)') |
WRITE(msgBuf,'(A)') |
503 |
& 'CONFIG_CHECK: restart not implemented in this config' |
& 'CONFIG_CHECK: restart not implemented in this config' |
504 |
CALL PRINT_ERROR( msgBuf , myThid) |
CALL PRINT_ERROR( msgBuf, myThid ) |
505 |
STOP 'ABNORMAL END: S/R CONFIG_CHECK' |
errCount = errCount + 1 |
506 |
ENDIF |
ENDIF |
507 |
|
|
508 |
IF ( useRealFreshWaterFlux .AND. .NOT.exactConserv |
IF ( useRealFreshWaterFlux .AND. .NOT.exactConserv |
509 |
& .AND. implicDiv2DFlow.NE.1. ) THEN |
& .AND. implicDiv2Dflow.NE.1. ) THEN |
510 |
WRITE(msgBuf,'(2A)') 'CONFIG_CHECK: **WARNNING** ', |
WRITE(msgBuf,'(2A)') '** WARNING ** CONFIG_CHECK: ', |
511 |
& 'RealFreshWater & implicDiv2DFlow < 1' |
& 'RealFreshWater & implicDiv2Dflow < 1' |
512 |
CALL PRINT_MESSAGE( msgBuf, errorMessageUnit, |
CALL PRINT_MESSAGE( msgBuf, errorMessageUnit, |
513 |
& SQUEEZE_RIGHT , myThid) |
& SQUEEZE_RIGHT, myThid ) |
514 |
WRITE(msgBuf,'(2A)') 'CONFIG_CHECK: works better', |
WRITE(msgBuf,'(2A)') '** WARNING ** works better', |
515 |
& ' with exactConserv=.T. (+ #define EXACT_CONSERV)' |
& ' with exactConserv=.T. (+ #define EXACT_CONSERV)' |
516 |
CALL PRINT_MESSAGE( msgBuf, errorMessageUnit, |
CALL PRINT_MESSAGE( msgBuf, errorMessageUnit, |
517 |
& SQUEEZE_RIGHT , myThid) |
& SQUEEZE_RIGHT, myThid ) |
518 |
ENDIF |
ENDIF |
519 |
|
|
520 |
#ifdef EXACT_CONSERV |
#ifdef EXACT_CONSERV |
521 |
IF (useRealFreshWaterFlux .AND. .NOT.exactConserv |
IF (useRealFreshWaterFlux .AND. .NOT.exactConserv |
522 |
& .AND. buoyancyRelation.EQ.'OCEANICP' ) THEN |
& .AND. buoyancyRelation.EQ.'OCEANICP' ) THEN |
523 |
WRITE(msgBuf,'(A)') |
WRITE(msgBuf,'(A)') |
524 |
& 'CONFIG_CHECK: RealFreshWaterFlux with OCEANICP' |
& 'CONFIG_CHECK: RealFreshWaterFlux with OCEANICP' |
525 |
CALL PRINT_ERROR( msgBuf , myThid) |
CALL PRINT_ERROR( msgBuf, myThid ) |
526 |
WRITE(msgBuf,'(A)') |
WRITE(msgBuf,'(A)') |
527 |
& 'CONFIG_CHECK: requires exactConserv=T' |
& 'CONFIG_CHECK: requires exactConserv=T' |
528 |
CALL PRINT_ERROR( msgBuf , myThid) |
CALL PRINT_ERROR( msgBuf, myThid ) |
529 |
STOP 'ABNORMAL END: S/R CONFIG_CHECK' |
errCount = errCount + 1 |
530 |
ENDIF |
ENDIF |
531 |
#else |
#else |
532 |
IF (useRealFreshWaterFlux |
IF (useRealFreshWaterFlux |
533 |
& .AND. buoyancyRelation.EQ.'OCEANICP' ) THEN |
& .AND. buoyancyRelation.EQ.'OCEANICP' ) THEN |
534 |
WRITE(msgBuf,'(A)') |
WRITE(msgBuf,'(2A)') '** WARNING ** CONFIG_CHECK: ', |
535 |
& 'CONFIG_CHECK: E-P effects on wVel are not included' |
& 'E-P effects on wVel are not included' |
536 |
CALL PRINT_MESSAGE( msgBuf, errorMessageUnit, |
CALL PRINT_MESSAGE( msgBuf, errorMessageUnit, |
537 |
& SQUEEZE_RIGHT , myThid) |
& SQUEEZE_RIGHT, myThid ) |
538 |
WRITE(msgBuf,'(A)') |
WRITE(msgBuf,'(2A)') '** WARNING ** CONFIG_CHECK: ', |
539 |
& 'CONFIG_CHECK: ==> use #define EXACT_CONSERV to fix it' |
& '==> use #define EXACT_CONSERV to fix it' |
540 |
CALL PRINT_MESSAGE( msgBuf, errorMessageUnit, |
CALL PRINT_MESSAGE( msgBuf, errorMessageUnit, |
541 |
& SQUEEZE_RIGHT , myThid) |
& SQUEEZE_RIGHT, myThid ) |
542 |
ENDIF |
ENDIF |
543 |
#endif /* EXACT_CONSERV */ |
#endif /* EXACT_CONSERV */ |
544 |
|
|
545 |
|
IF ( selectAddFluid.LT.-1 .OR. selectAddFluid.GT.2 ) THEN |
546 |
|
WRITE(msgBuf,'(A,I10,A)') 'CONFIG_CHECK: selectAddFluid=', |
547 |
|
& selectAddFluid, ' not allowed' |
548 |
|
CALL PRINT_ERROR( msgBuf, myThid ) |
549 |
|
WRITE(msgBuf,'(2A)') 'CONFIG_CHECK: ', |
550 |
|
& 'should be =0 (Off), 1,2 (Add Mass) or -1 (Virtual Flux)' |
551 |
|
CALL PRINT_ERROR( msgBuf, myThid ) |
552 |
|
errCount = errCount + 1 |
553 |
|
ENDIF |
554 |
|
IF ( selectAddFluid.GE.1 .AND. rigidLid ) THEN |
555 |
|
WRITE(msgBuf,'(A)') |
556 |
|
& 'CONFIG_CHECK: selectAddFluid > 0 not compatible with' |
557 |
|
CALL PRINT_ERROR( msgBuf, myThid ) |
558 |
|
WRITE(msgBuf,'(A)') |
559 |
|
& 'CONFIG_CHECK: rigidLid (meaningless in that case)' |
560 |
|
CALL PRINT_ERROR( msgBuf, myThid ) |
561 |
|
errCount = errCount + 1 |
562 |
|
ENDIF |
563 |
|
IF ( selectAddFluid.GE.1 .AND. .NOT.staggerTimeStep ) THEN |
564 |
|
WRITE(msgBuf,'(2A)') '** WARNING ** CONFIG_CHECK: ', |
565 |
|
& 'synchronous time-stepping =>' |
566 |
|
CALL PRINT_MESSAGE( msgBuf, errorMessageUnit, |
567 |
|
& SQUEEZE_RIGHT, myThid ) |
568 |
|
WRITE(msgBuf,'(2A)') '** WARNING ** ', |
569 |
|
& '1 time-step mismatch in AddFluid effects on T & S' |
570 |
|
CALL PRINT_MESSAGE( msgBuf, errorMessageUnit, |
571 |
|
& SQUEEZE_RIGHT, myThid ) |
572 |
|
ENDIF |
573 |
|
|
574 |
|
C-- Non-hydrostatic and 3-D solver related limitations: |
575 |
|
IF (nonlinFreeSurf.NE.0 .AND. use3Dsolver) THEN |
576 |
|
WRITE(msgBuf,'(A)') |
577 |
|
& 'CONFIG_CHECK: nonlinFreeSurf not yet implemented' |
578 |
|
CALL PRINT_ERROR( msgBuf, myThid ) |
579 |
|
WRITE(msgBuf,'(A)') |
580 |
|
& 'CONFIG_CHECK: in nonHydrostatic code' |
581 |
|
CALL PRINT_ERROR( msgBuf, myThid ) |
582 |
|
errCount = errCount + 1 |
583 |
|
ENDIF |
584 |
|
|
585 |
|
IF ( implicitNHPress*implicSurfPress*implicDiv2Dflow.NE.1. |
586 |
|
& .AND. implicitIntGravWave ) THEN |
587 |
|
WRITE(msgBuf,'(2A)') 'CONFIG_CHECK: implicitIntGravWave', |
588 |
|
& ' NOT SAFE with non-fully implicit solver' |
589 |
|
CALL PRINT_ERROR( msgBuf, myThid ) |
590 |
|
WRITE(msgBuf,'(2A)') 'CONFIG_CHECK: To by-pass this', |
591 |
|
& 'STOP, comment this test and re-compile config_check' |
592 |
|
CALL PRINT_ERROR( msgBuf, myThid ) |
593 |
|
errCount = errCount + 1 |
594 |
|
ENDIF |
595 |
|
IF ( nonHydrostatic .AND. .NOT.exactConserv |
596 |
|
& .AND. implicDiv2Dflow.NE.1. ) THEN |
597 |
|
WRITE(msgBuf,'(2A)') 'CONFIG_CHECK: Needs exactConserv=T', |
598 |
|
& ' for nonHydrostatic with implicDiv2Dflow < 1' |
599 |
|
CALL PRINT_ERROR( msgBuf, myThid ) |
600 |
|
errCount = errCount + 1 |
601 |
|
ENDIF |
602 |
|
IF ( nonHydrostatic .AND. |
603 |
|
& implicitNHPress.NE.implicSurfPress ) THEN |
604 |
|
WRITE(msgBuf,'(2A)') '** WARNING ** CONFIG_CHECK: ', |
605 |
|
& ' nonHydrostatic might cause problems with' |
606 |
|
CALL PRINT_MESSAGE( msgBuf, errorMessageUnit, |
607 |
|
& SQUEEZE_RIGHT, myThid ) |
608 |
|
WRITE(msgBuf,'(2A)') '** WARNING ** CONFIG_CHECK: ', |
609 |
|
& 'different implicitNHPress & implicSurfPress' |
610 |
|
CALL PRINT_MESSAGE( msgBuf, errorMessageUnit, |
611 |
|
& SQUEEZE_RIGHT, myThid ) |
612 |
|
ENDIF |
613 |
|
|
614 |
|
IF ( implicitViscosity .AND. use3Dsolver ) THEN |
615 |
|
WRITE(msgBuf,'(2A)') '** WARNING ** CONFIG_CHECK: ', |
616 |
|
& 'Implicit viscosity applies to provisional u,vVel' |
617 |
|
CALL PRINT_MESSAGE( msgBuf, errorMessageUnit, |
618 |
|
& SQUEEZE_RIGHT, myThid ) |
619 |
|
WRITE(msgBuf,'(2A)') '** WARNING ** => not consistent with', |
620 |
|
& 'final vertical shear (after appling 3-D solver solution' |
621 |
|
CALL PRINT_MESSAGE( msgBuf, errorMessageUnit, |
622 |
|
& SQUEEZE_RIGHT, myThid ) |
623 |
|
ENDIF |
624 |
|
IF ( implicitViscosity .AND. nonHydrostatic ) THEN |
625 |
|
WRITE(msgBuf,'(2A)') '** WARNING ** CONFIG_CHECK: ', |
626 |
|
& 'Implicit viscosity not implemented in CALC_GW' |
627 |
|
CALL PRINT_MESSAGE( msgBuf, errorMessageUnit, |
628 |
|
& SQUEEZE_RIGHT, myThid ) |
629 |
|
WRITE(msgBuf,'(2A)') '** WARNING ** CONFIG_CHECK: ', |
630 |
|
& 'Explicit viscosity might become unstable if too large' |
631 |
|
CALL PRINT_MESSAGE( msgBuf, errorMessageUnit, |
632 |
|
& SQUEEZE_RIGHT, myThid ) |
633 |
|
ENDIF |
634 |
|
|
635 |
|
C-- Momentum related limitations: |
636 |
|
IF ( vectorInvariantMomentum.AND.momStepping ) THEN |
637 |
|
IF ( highOrderVorticity.AND.upwindVorticity ) THEN |
638 |
|
WRITE(msgBuf,'(2A)') 'CONFIG_CHECK: ', |
639 |
|
& '"highOrderVorticity" conflicts with "upwindVorticity"' |
640 |
|
CALL PRINT_ERROR( msgBuf, myThid ) |
641 |
|
errCount = errCount + 1 |
642 |
|
ENDIF |
643 |
|
ENDIF |
644 |
|
IF ( selectCoriMap.LT.0 .OR. selectCoriMap.GT.3 ) THEN |
645 |
|
WRITE(msgBuf,'(2A,I4)') 'CONFIG_CHECK: ', |
646 |
|
& 'Invalid option: selectCoriMap=', selectCoriMap |
647 |
|
CALL PRINT_ERROR( msgBuf, myThid ) |
648 |
|
errCount = errCount + 1 |
649 |
|
ENDIF |
650 |
|
|
651 |
IF (.NOT.useCDscheme .AND. (tauCD.NE.0. .OR. rCD.NE.-1.) ) THEN |
IF (.NOT.useCDscheme .AND. (tauCD.NE.0. .OR. rCD.NE.-1.) ) THEN |
652 |
C- jmc: since useCDscheme is a new [04-13-03] flag (default=F), |
C- jmc: since useCDscheme is a new [04-13-03] flag (default=F), |
653 |
C put this WARNING to stress that even if CD-scheme parameters |
C put this WARNING to stress that even if CD-scheme parameters |
654 |
C (tauCD,rCD) are set, CD-scheme is not used without useCDscheme=T |
C (tauCD,rCD) are set, CD-scheme is not used without useCDscheme=T |
655 |
C- and STOP if using mom_fluxform (following Chris advise). |
C- and STOP if using mom_fluxform (following Chris advise). |
656 |
C- jmc: but ultimately, this block can/will be removed. |
C- jmc: but ultimately, this block can/will be removed. |
657 |
IF (.NOT.vectorInvariantMomentum.AND.momStepping) THEN |
IF (.NOT.vectorInvariantMomentum.AND.momStepping) THEN |
658 |
WRITE(msgBuf,'(A)') |
WRITE(msgBuf,'(A)') |
659 |
& 'CONFIG_CHECK: CD-scheme is OFF but params(tauCD,rCD) are set' |
& 'CONFIG_CHECK: CD-scheme is OFF but params(tauCD,rCD) are set' |
660 |
CALL PRINT_ERROR( msgBuf , myThid) |
CALL PRINT_ERROR( msgBuf, myThid ) |
661 |
WRITE(msgBuf,'(2A)') |
WRITE(msgBuf,'(2A)') |
662 |
& 'CONFIG_CHECK: to turn ON CD-scheme: => "useCDscheme=.TRUE."', |
& 'CONFIG_CHECK: to turn ON CD-scheme: => "useCDscheme=.TRUE."', |
663 |
& ' in "data", namelist PARM01' |
& ' in "data", namelist PARM01' |
664 |
CALL PRINT_ERROR( msgBuf , myThid) |
CALL PRINT_ERROR( msgBuf, myThid ) |
665 |
STOP 'ABNORMAL END: S/R CONFIG_CHECK' |
errCount = errCount + 1 |
666 |
ENDIF |
ENDIF |
667 |
WRITE(msgBuf,'(2A)') '**WARNNING** ', |
WRITE(msgBuf,'(2A)') '** WARNING ** CONFIG_CHECK: ', |
668 |
& 'CONFIG_CHECK: CD-scheme is OFF but params(tauCD,rCD) are set' |
& 'CD-scheme is OFF but params(tauCD,rCD) are set' |
669 |
CALL PRINT_MESSAGE( msgBuf, errorMessageUnit, |
CALL PRINT_MESSAGE( msgBuf, errorMessageUnit, |
670 |
& SQUEEZE_RIGHT , myThid) |
& SQUEEZE_RIGHT, myThid ) |
671 |
WRITE(msgBuf,'(2A)') |
WRITE(msgBuf,'(3A)') '** WARNING ** ', |
672 |
& 'CONFIG_CHECK: to turn ON CD-scheme: => "useCDscheme=.TRUE."', |
& 'to turn ON CD-scheme: => "useCDscheme=.TRUE."', |
673 |
& ' in "data", namelist PARM01' |
& ' in "data", namelist PARM01' |
674 |
|
WRITE(msgBuf,'(3A)') '** WARNING ** to turn ON CD-scheme:', |
675 |
|
& ' => "useCDscheme=.TRUE." in "data", namelist PARM01' |
676 |
CALL PRINT_MESSAGE( msgBuf, errorMessageUnit, |
CALL PRINT_MESSAGE( msgBuf, errorMessageUnit, |
677 |
& SQUEEZE_RIGHT , myThid) |
& SQUEEZE_RIGHT, myThid ) |
678 |
ENDIF |
ENDIF |
679 |
|
|
680 |
IF ( useCDscheme .AND. useCubedSphereExchange ) THEN |
IF ( useCDscheme .AND. useCubedSphereExchange ) THEN |
681 |
WRITE(msgBuf,'(2A)') |
WRITE(msgBuf,'(2A)') |
682 |
& 'CONFIG_CHECK: CD-scheme not implemented on CubedSphere grid' |
& 'CONFIG_CHECK: CD-scheme not implemented on CubedSphere grid' |
683 |
CALL PRINT_ERROR( msgBuf , myThid) |
CALL PRINT_ERROR( msgBuf, myThid ) |
684 |
STOP 'ABNORMAL END: S/R CONFIG_CHECK' |
cph errCount = errCount + 1 |
685 |
ENDIF |
ENDIF |
686 |
|
|
687 |
IF ( useOldFreezing .AND. allowFreezing ) THEN |
C-- Time-stepping limitations |
688 |
|
IF ( momForcingOutAB.NE.0 .AND. momForcingOutAB.NE.1 ) THEN |
689 |
|
WRITE(msgBuf,'(A,I10,A)') 'CONFIG_CHECK: momForcingOutAB=', |
690 |
|
& momForcingOutAB, ' not allowed' |
691 |
|
CALL PRINT_ERROR( msgBuf, myThid ) |
692 |
|
WRITE(msgBuf,'(2A)') 'CONFIG_CHECK: momForcingOutAB ', |
693 |
|
& 'should be =1 (Out of AB) or =0 (In AB)' |
694 |
|
CALL PRINT_ERROR( msgBuf, myThid ) |
695 |
|
errCount = errCount + 1 |
696 |
|
ENDIF |
697 |
|
IF ( tracForcingOutAB.NE.0 .AND. tracForcingOutAB.NE.1 ) THEN |
698 |
|
WRITE(msgBuf,'(A,I10,A)') 'CONFIG_CHECK: tracForcingOutAB=', |
699 |
|
& tracForcingOutAB, ' not allowed' |
700 |
|
CALL PRINT_ERROR( msgBuf, myThid ) |
701 |
|
WRITE(msgBuf,'(2A)') 'CONFIG_CHECK: tracForcingOutAB ', |
702 |
|
& 'should be =1 (Out of AB) or =0 (In AB)' |
703 |
|
CALL PRINT_ERROR( msgBuf, myThid ) |
704 |
|
errCount = errCount + 1 |
705 |
|
ENDIF |
706 |
|
|
707 |
|
C-- Grid limitations: |
708 |
|
IF ( rotateGrid ) THEN |
709 |
|
IF ( .NOT. usingSphericalPolarGrid ) THEN |
710 |
WRITE(msgBuf,'(2A)') |
WRITE(msgBuf,'(2A)') |
711 |
& 'CONFIG_CHECK: cannot set both: allowFreezing & useOldFreezing' |
& 'CONFIG_CHECK: specifying Euler angles makes only ', |
712 |
CALL PRINT_ERROR( msgBuf , myThid) |
& 'sense with usingSphericalGrid=.TRUE.' |
713 |
STOP 'ABNORMAL END: S/R CONFIG_CHECK' |
CALL PRINT_ERROR( msgBuf, myThid ) |
714 |
|
errCount = errCount + 1 |
715 |
|
ENDIF |
716 |
|
IF ( useFLT .OR. useZonal_Filt .OR. useECCO ) THEN |
717 |
|
WRITE(msgBuf,'(2A)') |
718 |
|
& 'CONFIG_CHECK: specifying Euler angles will probably ', |
719 |
|
& 'not work with pkgs FLT, ZONAL_FLT, ECCO' |
720 |
|
CALL PRINT_ERROR( msgBuf, myThid ) |
721 |
|
errCount = errCount + 1 |
722 |
|
ENDIF |
723 |
ENDIF |
ENDIF |
724 |
|
|
725 |
|
C-- Packages conflict |
726 |
IF ( useMATRIX .AND. useGCHEM ) THEN |
IF ( useMATRIX .AND. useGCHEM ) THEN |
727 |
WRITE(msgBuf,'(2A)') |
WRITE(msgBuf,'(2A)') |
728 |
& 'CONFIG_CHECK: cannot set both: useMATRIX & useGCHEM' |
& 'CONFIG_CHECK: cannot set both: useMATRIX & useGCHEM' |
729 |
CALL PRINT_ERROR( msgBuf , myThid) |
CALL PRINT_ERROR( msgBuf, myThid ) |
730 |
STOP 'ABNORMAL END: S/R CONFIG_CHECK' |
errCount = errCount + 1 |
731 |
ENDIF |
ENDIF |
732 |
|
|
733 |
IF ( useMATRIX .AND. .NOT.usePTRACERS ) THEN |
IF ( useMATRIX .AND. .NOT.usePTRACERS ) THEN |
734 |
WRITE(msgBuf,'(2A)') |
WRITE(msgBuf,'(2A)') |
735 |
& 'CONFIG_CHECK: cannot set useMATRIX without ', |
& 'CONFIG_CHECK: cannot set useMATRIX without ', |
736 |
& 'setting usePTRACERS' |
& 'setting usePTRACERS' |
737 |
CALL PRINT_ERROR( msgBuf , myThid) |
CALL PRINT_ERROR( msgBuf, myThid ) |
738 |
|
errCount = errCount + 1 |
739 |
|
ENDIF |
740 |
|
|
741 |
|
IF ( (useSEAICE .OR. useThSIce) .AND. allowFreezing ) THEN |
742 |
|
WRITE(msgBuf,'(2A)') |
743 |
|
& 'CONFIG_CHECK: cannot set allowFreezing', |
744 |
|
& ' with pkgs SEAICE or THSICE' |
745 |
|
CALL PRINT_ERROR( msgBuf, myThid ) |
746 |
|
errCount = errCount + 1 |
747 |
|
ENDIF |
748 |
|
|
749 |
|
IF ( errCount.GE.1 ) THEN |
750 |
|
WRITE(msgBuf,'(A,I3,A)') |
751 |
|
& 'CONFIG_CHECK: detected', errCount,' fatal error(s)' |
752 |
|
CALL PRINT_ERROR( msgBuf, myThid ) |
753 |
|
CALL ALL_PROC_DIE( 0 ) |
754 |
STOP 'ABNORMAL END: S/R CONFIG_CHECK' |
STOP 'ABNORMAL END: S/R CONFIG_CHECK' |
755 |
ENDIF |
ENDIF |
756 |
|
_END_MASTER(myThid) |
757 |
WRITE(msgBuf,'(A)') 'CONFIG_CHECK: OK' |
|
758 |
CALL PRINT_MESSAGE(msgBuf,standardMessageUnit, |
C---+----1----+----2----+----3----+----4----+----5----+----6----+----7-|--+----| |
759 |
& SQUEEZE_RIGHT,myThid) |
|
760 |
|
_BEGIN_MASTER(myThid) |
761 |
|
WRITE(msgBuf,'(A)') |
762 |
|
&'// =======================================================' |
763 |
|
CALL PRINT_MESSAGE( msgBuf, standardMessageUnit, |
764 |
|
& SQUEEZE_RIGHT, myThid ) |
765 |
|
WRITE(msgBuf,'(A)') '// CONFIG_CHECK : Normal End' |
766 |
|
CALL PRINT_MESSAGE( msgBuf, standardMessageUnit, |
767 |
|
& SQUEEZE_RIGHT, myThid ) |
768 |
|
WRITE(msgBuf,'(A)') |
769 |
|
&'// =======================================================' |
770 |
|
CALL PRINT_MESSAGE( msgBuf, standardMessageUnit, |
771 |
|
& SQUEEZE_RIGHT, myThid ) |
772 |
|
WRITE(msgBuf,'(A)') ' ' |
773 |
|
CALL PRINT_MESSAGE( msgBuf, standardMessageUnit, |
774 |
|
& SQUEEZE_RIGHT, myThid ) |
775 |
|
_END_MASTER(myThid) |
776 |
|
|
777 |
RETURN |
RETURN |
778 |
END |
END |