/[MITgcm]/MITgcm/doc/tag-index
ViewVC logotype

Diff of /MITgcm/doc/tag-index

Parent Directory Parent Directory | Revision Log Revision Log | View Revision Graph Revision Graph | View Patch Patch

revision 1.420 by edhill, Sat Dec 18 02:18:59 2004 UTC revision 1.444 by edhill, Mon Feb 7 18:37:19 2005 UTC
# Line 3  $Header$ Line 3  $Header$
3      Notes on tags used in MITgcmUV      Notes on tags used in MITgcmUV
4      ==============================      ==============================
5    
6    o add a "readgrid_mnc" flag to MNC and give model/src/ini_curvilinear_grid.F
7      the ability (off by default) to read the grid information using MNC
8    o diagnostics: fix a bug (sub-set of levels); keep full precision when averaging
9    o do snap-shot diagnostics at the middle of the time-interval (instead of
10      at the end).
11    o update exp. aim.5l_cs (use default LAND_OPTIONS.h file) and add
12      new test for AIM with thSIce + slab-ocean
13    o cpl_aim+ocn test: update output (optfile & default GMREDI_OPTIONS.h)
14    o move state variable diagnostics to the beginning of the time step ;
15      (note: still needs some work specially for snap-shot diagnostics)
16      duplicate & replace UVELVVEL diagnostics with UV_VEL_C & UV_VEL_Z
17    
18    checkpoint57c_post
19    o Change testing option (-ieee) to get closer agreement between g77 & ifort
20    o generate new output.txt files on faulks with g77 & the new -ieee option
21    checkpoint57c_pre
22    
23    o add "_d 0" in freeze ; change some "FLOAT" to "DFLOAT" and went back (TAF);
24      update output.txt of exp. global_ocean.90x40x15
25    o fix in ini_eos.F (one "_d 0" was missing): now g77 & ifc give much closer
26      results; update global_ocean_pressure & global_ocean.cs32x15 output.txt
27    o add saltFlux(+File) forcing capability with periodicExternalForcing
28    o allow to use pkg diagnostics for GM-Redi & ThSIce output
29    o diagnostics_fill: fill in up to sNx+1 or sNy+1 (if U,V or Z pt) for mnc.
30    o improvements for the MNC output from DIAGNOSTICS:
31      - correct handling of the unlimitied dimension
32      - all dims now have associated coordinate variables
33      - variables located at U, V, and Corner ("Z") points are now written
34        with the correct horzontal dimensions (eg. 'Xp1', 'Yp1') so that
35        *all* data points are output
36    o added seaice_summary.F and removed obsolete ALLOW_SEAICE's from pkg/seaice
37    o added pkg/seaice/seaice_monitor.F
38    o mdsio_readfield.F can now read files visible only to master MPI process.
39    o pkg/seaice: some test code for ice-modified ocean stress
40    o exf_getffields interpolation defaults to bilinear for all scalar forcing
41      fields (remains bicubic for wind velocity and stress).  This avoids, e.g.,
42      spurious negative numbers for precipitation and humidity.  Will cause
43      some small numerical differences for integrations using pkg/exf/exf_interp.F.
44    o pkg/ctrl/
45      * Add ctrlvec diagnostics in pack/unpack for nondimensional I/O
46        May be enabled via doPackDiag
47      *  introduce z-scaling of
48         + gradient (doZscalePack) and
49         + control (doZscaleUnpack)
50    o pkg/mdsio/
51      * enable useSingleCpuIO for state estimation (ctrl_pack/unpack) mdsio_gl.F
52      * N.B.: leave tiled I/O for tapelev (i.e. mds...vector)
53    
54    checkpoint57b_post
55    o simplify options in diagnostics_fill arguments (remove weird combinations)
56    o fix MNC coordinate variables so that they now contain per-face index
57      values (instead of xC,xG,yC,yG values) when run with EXCH2 since, in
58      general, EXCH2 grids are only aligned to a "local" coordinate system
59    o test diagnostics pkg in dic_example (no output) and ideal_2D_oce (with ouput)
60    o Implement instantaneous output within pkg diagnostics:
61      setting a negative frequency in data.diagnostics produces
62     "snap-shot" output (as opposed to time-average if freq > 0)
63    o move out off EQUIVALENCE all diagnostics that fizhi does not use ;
64      NOTE: change ptracer diagnostics name: use 2 characters to work with
65            more than 9 tracers. Add also diagnostics of advect & diffus flux.
66  o more CF compliance: convert all MNC 'iter' variables to 'T' so that it  o more CF compliance: convert all MNC 'iter' variables to 'T' so that it
67    becomes the coordinate variable for the 'T' dimension    becomes the coordinate variable for the 'T' dimension
68  o add CF-style coordinate variables to MNC  o add CF-style coordinate variables to MNC

Legend:
Removed from v.1.420  
changed lines
  Added in v.1.444

  ViewVC Help
Powered by ViewVC 1.1.22