/[MITgcm]/MITgcm/doc/tag-index
ViewVC logotype

Diff of /MITgcm/doc/tag-index

Parent Directory Parent Directory | Revision Log Revision Log | View Revision Graph Revision Graph | View Patch Patch

revision 1.438 by jmc, Thu Jan 27 17:37:28 2005 UTC revision 1.473 by heimbach, Thu Apr 7 23:40:07 2005 UTC
# Line 3  $Header$ Line 3  $Header$
3      Notes on tags used in MITgcmUV      Notes on tags used in MITgcmUV
4      ==============================      ==============================
5    
6    o make lambda[Theta,Salt]ClimRelax spatially varying
7      (default remains spatially uniform constant based on tau)
8    o added new control variables
9      * init. uVel, vVel, etanN
10      * lambda[Theta,Salt]ClimRelax
11    o separate masks used for ctrl_pack/unpack 'from write_grid' output
12      (suggested by G. Forget)
13    
14    checkpoint57f_post
15    o add parameter "baseTime" = model base time = time at iteration zero
16      new function DIFF_BASE_MULTIPLE (replace DIFFERENT_MULTIPLE) to
17      account for baseTime shift
18    o move Coriolis arrays from PARAMS.h to GRID.h
19    checkpoint57f_pre
20    
21    o mnc-ifying the seaice package
22    o introduced an alternative length scale calculation for use in the limiting
23      maximum viscosity (off by default, see mom_vi_hdissip.F for details)
24    o S/R ptracers_calc_diff: argument list bug for CALL KPP_CALC_DIFF_S
25    o added modified Leith scheme with viscosity proportional to grad(Hdiv)
26      as well as grad(vort3).  Made it compatible with both approximate form
27      for the cubed sphere and full form of these gradients.  Added flag
28      useFullLeith to select between approximate and full form.  
29    o add "d0" in getcon.F to reduce differences between compilers/platforms
30      update output.txt of exp. fizhi-gridalt-hs
31    o change port_rand funtion to allow to set the seed.
32    o fix obscure MNC bug involving conversion between reals and integers
33      - it caused no problems with certain (eg. gcc, ifc) compilers but the
34        new version is now more standards-compliant
35    o adjoint-related modifications
36      * gad_dst3_adv_?: to be able to use advscheme=30 in adjoint
37      * gad_calc_rhs: fool adjoint, revert to advscheme=30 in reverse when using 33
38      * mom_vi_hdissip: to be able to use Leith scheme in adjoint
39    
40    checkpoint57e_post
41    o Adding eddy stress controls a la Ferreira et al.
42    checkpoint57e_pre
43    
44    o fizhi pkg: fix AtoC and CtoA when called with same input & output array
45      update output.txt of exp. fizhi-gridalt-hs
46    o add more "Z" dimensions and associated coordinate vars to MNC
47    o pkg/exf: added twoDigitYear capability for option useExfYearlyFields
48    o parameter calendarDumps: when set, approximate months (30-31 days) and years
49      (360-372 days) for parameters chkPtFreq, pChkPtFreq, taveFreq, SEAICE_taveFreq,
50      KPP_taveFreq, and freq in pkg/diagnostics are converted to exact calendar
51      months and years.  Requires pkg/cal.
52    o diagnostics: add pickup functionality
53      - off by default for backwards compatibility
54      - current version only uses MDSIO -- MNC will be added
55    o allow to use pkg diagnostics for LAND pkg output & Shapiro Tendencies.
56    o pkg/shap_filt: fix for multi-tiles per face (CS-grid with EXCH2)
57    
58    checkpoint57d_post
59    o pkg/thsice used in the ocean: fix tile Pb related to sIceLoad forcing
60    o modify verification/ideal_2D_oce so that it tests the creation of mnc
61      output from the diagnostics package
62    o temporary fix in EXCH2_UV: add a 3rd call to fix the 24.tiles CS-grid set-up
63    o make genmake2 more portable by using ".$FS" instead of ".f" for more
64      of the test compilations (eg. IBM xlf on Mac OSX w/HFS filesys)
65    o add coordinate variables to the MNC output from the diagnostics package
66    o change MNC-flags default value: true when useMNC=TRUE
67    o add a "readgrid_mnc" flag to MNC and give model/src/ini_curvilinear_grid.F
68      the ability (off by default) to read the grid information using MNC
69    o lab_sea: use LSR_ERROR=1.E-12 for testing ; update output.txt
70    o diagnostics: fix a bug (sub-set of levels); keep full precision when averaging
71    o do snap-shot diagnostics at the middle of the time-interval (instead of
72      at the end).
73    o update exp. aim.5l_cs (use default LAND_OPTIONS.h file) and add
74      new test for AIM with thSIce + slab-ocean
75    o cpl_aim+ocn test: update output (optfile & default GMREDI_OPTIONS.h)
76    o move state variable diagnostics to the beginning of the time step ;
77      (note: still needs some work specially for snap-shot diagnostics)
78      duplicate & replace UVELVVEL diagnostics with UV_VEL_C & UV_VEL_Z
79    
80  checkpoint57c_post  checkpoint57c_post
81  o Change testing option (-ieee) to get closer agreement between g77 & ifort  o Change testing option (-ieee) to get closer agreement between g77 & ifort
82  o generate new output.txt files on faulks with g77 & the new -ieee option  o generate new output.txt files on faulks with g77 & the new -ieee option

Legend:
Removed from v.1.438  
changed lines
  Added in v.1.473

  ViewVC Help
Powered by ViewVC 1.1.22