/[MITgcm]/MITgcm/doc/tag-index
ViewVC logotype

Diff of /MITgcm/doc/tag-index

Parent Directory Parent Directory | Revision Log Revision Log | View Revision Graph Revision Graph | View Patch Patch

revision 1.423 by edhill, Mon Dec 20 17:10:27 2004 UTC revision 1.438 by jmc, Thu Jan 27 17:37:28 2005 UTC
# Line 3  $Header$ Line 3  $Header$
3      Notes on tags used in MITgcmUV      Notes on tags used in MITgcmUV
4      ==============================      ==============================
5    
6    checkpoint57c_post
7    o Change testing option (-ieee) to get closer agreement between g77 & ifort
8    o generate new output.txt files on faulks with g77 & the new -ieee option
9    checkpoint57c_pre
10    
11    o add "_d 0" in freeze ; change some "FLOAT" to "DFLOAT" and went back (TAF);
12      update output.txt of exp. global_ocean.90x40x15
13    o fix in ini_eos.F (one "_d 0" was missing): now g77 & ifc give much closer
14      results; update global_ocean_pressure & global_ocean.cs32x15 output.txt
15    o add saltFlux(+File) forcing capability with periodicExternalForcing
16    o allow to use pkg diagnostics for GM-Redi & ThSIce output
17    o diagnostics_fill: fill in up to sNx+1 or sNy+1 (if U,V or Z pt) for mnc.
18    o improvements for the MNC output from DIAGNOSTICS:
19      - correct handling of the unlimitied dimension
20      - all dims now have associated coordinate variables
21      - variables located at U, V, and Corner ("Z") points are now written
22        with the correct horzontal dimensions (eg. 'Xp1', 'Yp1') so that
23        *all* data points are output
24    o added seaice_summary.F and removed obsolete ALLOW_SEAICE's from pkg/seaice
25    o added pkg/seaice/seaice_monitor.F
26    o mdsio_readfield.F can now read files visible only to master MPI process.
27    o pkg/seaice: some test code for ice-modified ocean stress
28    o exf_getffields interpolation defaults to bilinear for all scalar forcing
29      fields (remains bicubic for wind velocity and stress).  This avoids, e.g.,
30      spurious negative numbers for precipitation and humidity.  Will cause
31      some small numerical differences for integrations using pkg/exf/exf_interp.F.
32    o pkg/ctrl/
33      * Add ctrlvec diagnostics in pack/unpack for nondimensional I/O
34        May be enabled via doPackDiag
35      *  introduce z-scaling of
36         + gradient (doZscalePack) and
37         + control (doZscaleUnpack)
38    o pkg/mdsio/
39      * enable useSingleCpuIO for state estimation (ctrl_pack/unpack) mdsio_gl.F
40      * N.B.: leave tiled I/O for tapelev (i.e. mds...vector)
41    
42    checkpoint57b_post
43    o simplify options in diagnostics_fill arguments (remove weird combinations)
44  o fix MNC coordinate variables so that they now contain per-face index  o fix MNC coordinate variables so that they now contain per-face index
45    values (instead of xC,xG,yC,yG values) when run with EXCH2 since, in    values (instead of xC,xG,yC,yG values) when run with EXCH2 since, in
46    general, EXCH2 grids are only aligned to a "local" coordinate system    general, EXCH2 grids are only aligned to a "local" coordinate system

Legend:
Removed from v.1.423  
changed lines
  Added in v.1.438

  ViewVC Help
Powered by ViewVC 1.1.22