/[MITgcm]/MITgcm/doc/tag-index
ViewVC logotype

Diff of /MITgcm/doc/tag-index

Parent Directory Parent Directory | Revision Log Revision Log | View Revision Graph Revision Graph | View Patch Patch

revision 1.416 by jmc, Fri Dec 17 00:52:42 2004 UTC revision 1.426 by dimitri, Wed Dec 22 00:49:36 2004 UTC
# Line 3  $Header$ Line 3  $Header$
3      Notes on tags used in MITgcmUV      Notes on tags used in MITgcmUV
4      ==============================      ==============================
5    
6    o pkg/seaice: some test code for ice-modified ocean stress
7    o exf_getffields interpolation defaults to bilinear for all scalar forcing
8      fields (remains bicubic for wind velocity and stress).  This avoids, e.g.,
9      spurious negative numbers for precipitation and humidity.  Will cause
10      some small numerical differences for integrations using pkg/exf/exf_interp.F.
11    
12    checkpoint57b_post
13    o simplify options in diagnostics_fill arguments (remove weird combinations)
14    o fix MNC coordinate variables so that they now contain per-face index
15      values (instead of xC,xG,yC,yG values) when run with EXCH2 since, in
16      general, EXCH2 grids are only aligned to a "local" coordinate system
17    o test diagnostics pkg in dic_example (no output) and ideal_2D_oce (with ouput)
18    o Implement instantaneous output within pkg diagnostics:
19      setting a negative frequency in data.diagnostics produces
20     "snap-shot" output (as opposed to time-average if freq > 0)
21    o move out off EQUIVALENCE all diagnostics that fizhi does not use ;
22      NOTE: change ptracer diagnostics name: use 2 characters to work with
23            more than 9 tracers. Add also diagnostics of advect & diffus flux.
24    o more CF compliance: convert all MNC 'iter' variables to 'T' so that it
25      becomes the coordinate variable for the 'T' dimension
26    o add CF-style coordinate variables to MNC
27      - just a first cut:  numbers are meaningless on the cubesphere and
28        missing along the T axis but otherwise it works!
29    o add surface flux diagnostics: TAUX, TAUY, TFLUX, TRELAX, TICE, SFLUX, SRELAX
30    o pkg/thSIce: read initial state from 6 files ; allow monitor to use MNC.
31  o add diagnostics of advective & diffusive flux for T & S (pTracers coming soon)  o add diagnostics of advective & diffusive flux for T & S (pTracers coming soon)
32    this is based directly on what the model compute, so that the content of    this is based directly on what the model compute, so that the content of
33    each diagnostics might be affected by switching options (e.g., implicitDiffusion)    each diagnostics might be affected by switching options (e.g., implicitDiffusion)

Legend:
Removed from v.1.416  
changed lines
  Added in v.1.426

  ViewVC Help
Powered by ViewVC 1.1.22