/[MITgcm]/MITgcm/doc/tag-index
ViewVC logotype

Diff of /MITgcm/doc/tag-index

Parent Directory Parent Directory | Revision Log Revision Log | View Revision Graph Revision Graph | View Patch Patch

revision 1.390 by jmc, Sun Nov 21 22:22:31 2004 UTC revision 1.446 by jmc, Tue Feb 8 18:07:26 2005 UTC
# Line 3  $Header$ Line 3  $Header$
3      Notes on tags used in MITgcmUV      Notes on tags used in MITgcmUV
4      ==============================      ==============================
5    
6    o change MNC-flags default value: true when useMNC=TRUE
7    o add a "readgrid_mnc" flag to MNC and give model/src/ini_curvilinear_grid.F
8      the ability (off by default) to read the grid information using MNC
9    o lab_sea: use LSR_ERROR=1.E-12 for testing ; update output.txt
10    o diagnostics: fix a bug (sub-set of levels); keep full precision when averaging
11    o do snap-shot diagnostics at the middle of the time-interval (instead of
12      at the end).
13    o update exp. aim.5l_cs (use default LAND_OPTIONS.h file) and add
14      new test for AIM with thSIce + slab-ocean
15    o cpl_aim+ocn test: update output (optfile & default GMREDI_OPTIONS.h)
16    o move state variable diagnostics to the beginning of the time step ;
17      (note: still needs some work specially for snap-shot diagnostics)
18      duplicate & replace UVELVVEL diagnostics with UV_VEL_C & UV_VEL_Z
19    
20    checkpoint57c_post
21    o Change testing option (-ieee) to get closer agreement between g77 & ifort
22    o generate new output.txt files on faulks with g77 & the new -ieee option
23    checkpoint57c_pre
24    
25    o add "_d 0" in freeze ; change some "FLOAT" to "DFLOAT" and went back (TAF);
26      update output.txt of exp. global_ocean.90x40x15
27    o fix in ini_eos.F (one "_d 0" was missing): now g77 & ifc give much closer
28      results; update global_ocean_pressure & global_ocean.cs32x15 output.txt
29    o add saltFlux(+File) forcing capability with periodicExternalForcing
30    o allow to use pkg diagnostics for GM-Redi & ThSIce output
31    o diagnostics_fill: fill in up to sNx+1 or sNy+1 (if U,V or Z pt) for mnc.
32    o improvements for the MNC output from DIAGNOSTICS:
33      - correct handling of the unlimitied dimension
34      - all dims now have associated coordinate variables
35      - variables located at U, V, and Corner ("Z") points are now written
36        with the correct horzontal dimensions (eg. 'Xp1', 'Yp1') so that
37        *all* data points are output
38    o added seaice_summary.F and removed obsolete ALLOW_SEAICE's from pkg/seaice
39    o added pkg/seaice/seaice_monitor.F
40    o mdsio_readfield.F can now read files visible only to master MPI process.
41    o pkg/seaice: some test code for ice-modified ocean stress
42    o exf_getffields interpolation defaults to bilinear for all scalar forcing
43      fields (remains bicubic for wind velocity and stress).  This avoids, e.g.,
44      spurious negative numbers for precipitation and humidity.  Will cause
45      some small numerical differences for integrations using pkg/exf/exf_interp.F.
46    o pkg/ctrl/
47      * Add ctrlvec diagnostics in pack/unpack for nondimensional I/O
48        May be enabled via doPackDiag
49      *  introduce z-scaling of
50         + gradient (doZscalePack) and
51         + control (doZscaleUnpack)
52    o pkg/mdsio/
53      * enable useSingleCpuIO for state estimation (ctrl_pack/unpack) mdsio_gl.F
54      * N.B.: leave tiled I/O for tapelev (i.e. mds...vector)
55    
56    checkpoint57b_post
57    o simplify options in diagnostics_fill arguments (remove weird combinations)
58    o fix MNC coordinate variables so that they now contain per-face index
59      values (instead of xC,xG,yC,yG values) when run with EXCH2 since, in
60      general, EXCH2 grids are only aligned to a "local" coordinate system
61    o test diagnostics pkg in dic_example (no output) and ideal_2D_oce (with ouput)
62    o Implement instantaneous output within pkg diagnostics:
63      setting a negative frequency in data.diagnostics produces
64     "snap-shot" output (as opposed to time-average if freq > 0)
65    o move out off EQUIVALENCE all diagnostics that fizhi does not use ;
66      NOTE: change ptracer diagnostics name: use 2 characters to work with
67            more than 9 tracers. Add also diagnostics of advect & diffus flux.
68    o more CF compliance: convert all MNC 'iter' variables to 'T' so that it
69      becomes the coordinate variable for the 'T' dimension
70    o add CF-style coordinate variables to MNC
71      - just a first cut:  numbers are meaningless on the cubesphere and
72        missing along the T axis but otherwise it works!
73    o add surface flux diagnostics: TAUX, TAUY, TFLUX, TRELAX, TICE, SFLUX, SRELAX
74    o pkg/thSIce: read initial state from 6 files ; allow monitor to use MNC.
75    o add diagnostics of advective & diffusive flux for T & S (pTracers coming soon)
76      this is based directly on what the model compute, so that the content of
77      each diagnostics might be affected by switching options (e.g., implicitDiffusion)
78    o small changes for diagnostics (gad_biharm_?.F, arguments of S/R impldiff.F)
79    o clean up build options files for SunOS, in particular
80      - remove -traditional from xmakedepend
81      - change -xarch=v9 to -xarch=native for f77
82      - restore use of make (not gmake)
83      - add CC=gcc if using g77
84    o changes per discussion of AM, JMC, & EH3 today:
85      - move redundant "grid" variables out of "state" -- in preparation of
86        creating proper CF-style coordinate variables and in recognition
87        that any/all grid variables can be easily copied (eg. w/NCO) from
88        the grid files into any of the other NetCDF files
89      - *always* output grid variables with MDSIO (this will eventually be
90        changed)
91      - output MNC grid file if useMNC is true
92    o every instance of _END_MASTER() has been found and replaced with
93      _END_MASTER( myThid ) in order to satisfy certain picky Sun
94      preprocessors
95    o re-arrange diagnostics pkg initialisation:
96     - allow each package to extend the available diagnostics list
97     - add some checking and fix small problems (multi-threaded, ...)
98     - new S/R diagnostics_fill (replace fill_diagnostics):
99       look through the short list of active diag. (instead of the long list)
100       create function DIAGNOSTICS_IS_ON to tell if a diagnostics is active
101    
102    checkpoint57a_post
103    o this set of changes restores TAMC compatibility
104      tested for global_ocean.90x40x15 adjoint on trough
105      (what a pain)
106    
107    checkpoint57a_pre
108    o some modifs in tools/build_options for sunos
109    o call ctrl_pack for ctrl at end for optimcycle=0
110    
111    checkpoint57
112    o add horizontal bi-harmonic viscosity for vertical velocity
113      - new parameter viscA4W (defaults to viscA4)
114      - affects only non-hydrostatic code
115      - to be done: no-slip lateral boundary conditions
116    o switch back to "sflux = sflux - runoff" in exf_getforcing.F
117    o implement Implicit Vertical advection for pTracers
118    o depth convergence accelerator: replace deltaTtracer by dTtracerLev(k)
119      (implemented also for implicit vertical diffusion & advection)
120    o OBCS: extend application of tracer open boundary conditions
121      to a strip beyond the boundary of width Olx/Oly
122    o add call monitor to TAF set of required calls (flow directives)
123      and include in natl_box_adjoint
124    o untangle a few ifdefs related to cost, ctrl, autodiff
125      untangel a few ALLOW_ECCO_OPTIMIZATION
126    o Apply Cooper & Haines representative estimates also at sub-surface (k=Nr)
127      (theta2, salt2 in ecco_cost_weights)
128    
129    checkpoint56c_post
130    o OBCS as control variables
131      - update ctrl_ad_diff.list, obcs_ad_diff.list
132      - remove balance of obcs controls from default
133      - fix index bug nobcs in ctrl_init
134      - fix dummy fields filen in ctrl_pack
135      - add dummy weights for obcs
136    o lsopt: comment out fort.94 output
137    o optim:
138      - remove unnecessary header files
139      - adjusted namelists
140      - add xerbla.F to Makefile
141    o exf:
142      - multiple modifications of exf_check_range
143      - unit change in exf_init_runoff from [m/year] to [m/s]
144    o mdsio:
145      - i/o-vector change debugLevel from debLevA to debLevB
146    
147    checkpoint56b_post
148    o collect all ptracers output in an new routine (PTRACERS_OUTPUT) that
149      is called from DO_THE_MODEL_IO
150      - rename PTRACERS_STATV_WRITE to PTRACERS_WRITE_TIMEAVE
151      - introduce new parameter PTRACERS_dumpFreq (defaults to dumpFreq)
152      - clean up PTRACERS_WRITE_TIMEAVE a little
153    o add another verification experiment that tests both the cfc-pkg and
154      the gchem-pkg with GCHEM_SEPARATE_FORCING undefined, that is with
155      reactive tendencies treated inline with regular timestepping
156    o testreport previously did a lousy job of comparing small numbers, so
157      we (Ed and Martin) changed the  way the cut-off of 1.e-12 is
158      implemented in the little c-progam tmp_cmpnum.c which is embedded in
159      testreport.
160    o ptracers_monitor: bug fix for MPI
161    
162    checkpoint56a_post
163    o GCHEM: finish reorganizating the package
164      - forward_step calls GCHEM_CALC_TENDENDY, which computes gchemTendency
165        (introduces another 3D-array for each passive tracer, but only if
166        GCHEM_SEPARATE_FORCING is undefined. For GCHEM_SEPARATE_FORCING
167        gchemTendency is not needed because the timestep is done separately)
168      - gchemTendency is added to gPtr in GCHEM_ADD_TENDENCY
169      - GCHEM is now---more or less cleanly---separate from PTRACERS
170      - to bo done: handling of surfaceForcingPtr that is needed for KPP not
171        so clear to me how that should be done in a general way.
172    o CFC: improve formatting of output in CFC_ATMOS
173    o PTRACERS:
174      - rename GCHEM_MONITOR to PTRACERS_MONITOR and call it from MONITOR, so
175        that ALL experiments with ptracers enable can be checked. This makes
176        GCHEM_MONITOR obsolete.
177      - include a runtime parameter PTRACERS_monitorFreq that defaults to
178        monitorFreq
179      - set default PTRACERS_write_mdsio to false if PTRACERS_write_mnc is true
180    o add PTRACERS (PTR0[1-5]) to testreport output
181    o exf_check_range:
182      * default changed to .TRUE.
183      * will check values for niter0 if debLevA, every timestep if debLevB
184      * STOP in exf_check_range if 'out of range'
185      * range chosen generous to allow for potential extema
186      TBD: a version with stricter range
187           permitted range would be runtime parameters
188  o GMredi:  o GMredi:
189    - fix ldd97 slope limit ; extend valid domain of Psi-Bolus ;    - fix ldd97 slope limit ; extend valid domain of Psi-Bolus ;
190    - change S/R GRAD_SIGMA to be valid in the overlap on CS-grid.    - change S/R GRAD_SIGMA to be valid in the overlap on CS-grid.
# Line 11  o GCHEM: Line 193  o GCHEM:
193    - move call to GCHEM_FORCING_SEP, so that it is now called before    - move call to GCHEM_FORCING_SEP, so that it is now called before
194      the blocking exchanges to avoid computing halos in GCHEM_FORCING_SEP      the blocking exchanges to avoid computing halos in GCHEM_FORCING_SEP
195    - introduced a useGCHEM runtime flag and applied it everywhere.    - introduced a useGCHEM runtime flag and applied it everywhere.
196      - renamed PTRACERS_SEPARATE_FORCING to GCHEM_SEPARATE_FORCING;
197        this flag is now only visible within GCHEM-pkg routines.
198      - moved gchem_forcing_int temporarily into ptracers_forcing, this will
199        be replaced by a 3D array that is computed before thermodynamics; for
200        this, the tracer ID iTracer had to be included into the parameter list
201        of ptracers_forcing
202      - set up forward_step to call gchem_forcing, that will replace
203        gchem_forcing_int in ptracers_forcing
204      - cleaning up
205  o small cleaning of exch2: remove files that are also in eesupp/src  o small cleaning of exch2: remove files that are also in eesupp/src
206    
207  checkpoint56  checkpoint56

Legend:
Removed from v.1.390  
changed lines
  Added in v.1.446

  ViewVC Help
Powered by ViewVC 1.1.22