/[MITgcm]/MITgcm/doc/tag-index
ViewVC logotype

Diff of /MITgcm/doc/tag-index

Parent Directory Parent Directory | Revision Log Revision Log | View Revision Graph Revision Graph | View Patch Patch

revision 1.417 by jmc, Fri Dec 17 05:03:43 2004 UTC revision 1.448 by edhill, Wed Feb 9 17:34:19 2005 UTC
# Line 3  $Header$ Line 3  $Header$
3      Notes on tags used in MITgcmUV      Notes on tags used in MITgcmUV
4      ==============================      ==============================
5    
6    o make genmake2 more portable by using ".$FS" instead of ".f" for more
7      of the test compilations (eg. IBM xlf on Mac OSX w/HFS filesys)
8    o add coordinate variables to the MNC output from the diagnostics package
9    o change MNC-flags default value: true when useMNC=TRUE
10    o add a "readgrid_mnc" flag to MNC and give model/src/ini_curvilinear_grid.F
11      the ability (off by default) to read the grid information using MNC
12    o lab_sea: use LSR_ERROR=1.E-12 for testing ; update output.txt
13    o diagnostics: fix a bug (sub-set of levels); keep full precision when averaging
14    o do snap-shot diagnostics at the middle of the time-interval (instead of
15      at the end).
16    o update exp. aim.5l_cs (use default LAND_OPTIONS.h file) and add
17      new test for AIM with thSIce + slab-ocean
18    o cpl_aim+ocn test: update output (optfile & default GMREDI_OPTIONS.h)
19    o move state variable diagnostics to the beginning of the time step ;
20      (note: still needs some work specially for snap-shot diagnostics)
21      duplicate & replace UVELVVEL diagnostics with UV_VEL_C & UV_VEL_Z
22    
23    checkpoint57c_post
24    o Change testing option (-ieee) to get closer agreement between g77 & ifort
25    o generate new output.txt files on faulks with g77 & the new -ieee option
26    checkpoint57c_pre
27    
28    o add "_d 0" in freeze ; change some "FLOAT" to "DFLOAT" and went back (TAF);
29      update output.txt of exp. global_ocean.90x40x15
30    o fix in ini_eos.F (one "_d 0" was missing): now g77 & ifc give much closer
31      results; update global_ocean_pressure & global_ocean.cs32x15 output.txt
32    o add saltFlux(+File) forcing capability with periodicExternalForcing
33    o allow to use pkg diagnostics for GM-Redi & ThSIce output
34    o diagnostics_fill: fill in up to sNx+1 or sNy+1 (if U,V or Z pt) for mnc.
35    o improvements for the MNC output from DIAGNOSTICS:
36      - correct handling of the unlimitied dimension
37      - all dims now have associated coordinate variables
38      - variables located at U, V, and Corner ("Z") points are now written
39        with the correct horzontal dimensions (eg. 'Xp1', 'Yp1') so that
40        *all* data points are output
41    o added seaice_summary.F and removed obsolete ALLOW_SEAICE's from pkg/seaice
42    o added pkg/seaice/seaice_monitor.F
43    o mdsio_readfield.F can now read files visible only to master MPI process.
44    o pkg/seaice: some test code for ice-modified ocean stress
45    o exf_getffields interpolation defaults to bilinear for all scalar forcing
46      fields (remains bicubic for wind velocity and stress).  This avoids, e.g.,
47      spurious negative numbers for precipitation and humidity.  Will cause
48      some small numerical differences for integrations using pkg/exf/exf_interp.F.
49    o pkg/ctrl/
50      * Add ctrlvec diagnostics in pack/unpack for nondimensional I/O
51        May be enabled via doPackDiag
52      *  introduce z-scaling of
53         + gradient (doZscalePack) and
54         + control (doZscaleUnpack)
55    o pkg/mdsio/
56      * enable useSingleCpuIO for state estimation (ctrl_pack/unpack) mdsio_gl.F
57      * N.B.: leave tiled I/O for tapelev (i.e. mds...vector)
58    
59    checkpoint57b_post
60    o simplify options in diagnostics_fill arguments (remove weird combinations)
61    o fix MNC coordinate variables so that they now contain per-face index
62      values (instead of xC,xG,yC,yG values) when run with EXCH2 since, in
63      general, EXCH2 grids are only aligned to a "local" coordinate system
64    o test diagnostics pkg in dic_example (no output) and ideal_2D_oce (with ouput)
65    o Implement instantaneous output within pkg diagnostics:
66      setting a negative frequency in data.diagnostics produces
67     "snap-shot" output (as opposed to time-average if freq > 0)
68    o move out off EQUIVALENCE all diagnostics that fizhi does not use ;
69      NOTE: change ptracer diagnostics name: use 2 characters to work with
70            more than 9 tracers. Add also diagnostics of advect & diffus flux.
71    o more CF compliance: convert all MNC 'iter' variables to 'T' so that it
72      becomes the coordinate variable for the 'T' dimension
73    o add CF-style coordinate variables to MNC
74      - just a first cut:  numbers are meaningless on the cubesphere and
75        missing along the T axis but otherwise it works!
76    o add surface flux diagnostics: TAUX, TAUY, TFLUX, TRELAX, TICE, SFLUX, SRELAX
77  o pkg/thSIce: read initial state from 6 files ; allow monitor to use MNC.  o pkg/thSIce: read initial state from 6 files ; allow monitor to use MNC.
78  o add diagnostics of advective & diffusive flux for T & S (pTracers coming soon)  o add diagnostics of advective & diffusive flux for T & S (pTracers coming soon)
79    this is based directly on what the model compute, so that the content of    this is based directly on what the model compute, so that the content of

Legend:
Removed from v.1.417  
changed lines
  Added in v.1.448

  ViewVC Help
Powered by ViewVC 1.1.22