/[MITgcm]/MITgcm/doc/tag-index
ViewVC logotype

Diff of /MITgcm/doc/tag-index

Parent Directory Parent Directory | Revision Log Revision Log | View Revision Graph Revision Graph | View Patch Patch

revision 1.416 by jmc, Fri Dec 17 00:52:42 2004 UTC revision 1.425 by dimitri, Mon Dec 20 23:32:52 2004 UTC
# Line 3  $Header$ Line 3  $Header$
3      Notes on tags used in MITgcmUV      Notes on tags used in MITgcmUV
4      ==============================      ==============================
5    
6    o exf_getffields interpolation defaults to bilinear for all scalar forcing
7      fields (remains bicubic for wind velocity and stress).  This avoids, e.g.,
8      spurious negative numbers for precipitation and humidity.  Will cause
9      some small numerical differences for integrations using pkg/exf/exf_interp.F.
10    
11    checkpoint57b_post
12    o simplify options in diagnostics_fill arguments (remove weird combinations)
13    o fix MNC coordinate variables so that they now contain per-face index
14      values (instead of xC,xG,yC,yG values) when run with EXCH2 since, in
15      general, EXCH2 grids are only aligned to a "local" coordinate system
16    o test diagnostics pkg in dic_example (no output) and ideal_2D_oce (with ouput)
17    o Implement instantaneous output within pkg diagnostics:
18      setting a negative frequency in data.diagnostics produces
19     "snap-shot" output (as opposed to time-average if freq > 0)
20    o move out off EQUIVALENCE all diagnostics that fizhi does not use ;
21      NOTE: change ptracer diagnostics name: use 2 characters to work with
22            more than 9 tracers. Add also diagnostics of advect & diffus flux.
23    o more CF compliance: convert all MNC 'iter' variables to 'T' so that it
24      becomes the coordinate variable for the 'T' dimension
25    o add CF-style coordinate variables to MNC
26      - just a first cut:  numbers are meaningless on the cubesphere and
27        missing along the T axis but otherwise it works!
28    o add surface flux diagnostics: TAUX, TAUY, TFLUX, TRELAX, TICE, SFLUX, SRELAX
29    o pkg/thSIce: read initial state from 6 files ; allow monitor to use MNC.
30  o add diagnostics of advective & diffusive flux for T & S (pTracers coming soon)  o add diagnostics of advective & diffusive flux for T & S (pTracers coming soon)
31    this is based directly on what the model compute, so that the content of    this is based directly on what the model compute, so that the content of
32    each diagnostics might be affected by switching options (e.g., implicitDiffusion)    each diagnostics might be affected by switching options (e.g., implicitDiffusion)

Legend:
Removed from v.1.416  
changed lines
  Added in v.1.425

  ViewVC Help
Powered by ViewVC 1.1.22