/[MITgcm]/MITgcm/doc/tag-index
ViewVC logotype

Diff of /MITgcm/doc/tag-index

Parent Directory Parent Directory | Revision Log Revision Log | View Revision Graph Revision Graph | View Patch Patch

revision 1.407 by heimbach, Thu Dec 9 15:37:25 2004 UTC revision 1.439 by jmc, Fri Jan 28 01:32:09 2005 UTC
# Line 3  $Header$ Line 3  $Header$
3      Notes on tags used in MITgcmUV      Notes on tags used in MITgcmUV
4      ==============================      ==============================
5    
6    o move state variable diagnostics to the beginning of the time step ;
7      (note: still needs some work specially for snap-shot diagnostics)
8      duplicate & replace UVELVVEL diagnostics with UV_VEL_C & UV_VEL_Z
9    
10    checkpoint57c_post
11    o Change testing option (-ieee) to get closer agreement between g77 & ifort
12    o generate new output.txt files on faulks with g77 & the new -ieee option
13    checkpoint57c_pre
14    
15    o add "_d 0" in freeze ; change some "FLOAT" to "DFLOAT" and went back (TAF);
16      update output.txt of exp. global_ocean.90x40x15
17    o fix in ini_eos.F (one "_d 0" was missing): now g77 & ifc give much closer
18      results; update global_ocean_pressure & global_ocean.cs32x15 output.txt
19    o add saltFlux(+File) forcing capability with periodicExternalForcing
20    o allow to use pkg diagnostics for GM-Redi & ThSIce output
21    o diagnostics_fill: fill in up to sNx+1 or sNy+1 (if U,V or Z pt) for mnc.
22    o improvements for the MNC output from DIAGNOSTICS:
23      - correct handling of the unlimitied dimension
24      - all dims now have associated coordinate variables
25      - variables located at U, V, and Corner ("Z") points are now written
26        with the correct horzontal dimensions (eg. 'Xp1', 'Yp1') so that
27        *all* data points are output
28    o added seaice_summary.F and removed obsolete ALLOW_SEAICE's from pkg/seaice
29    o added pkg/seaice/seaice_monitor.F
30    o mdsio_readfield.F can now read files visible only to master MPI process.
31    o pkg/seaice: some test code for ice-modified ocean stress
32    o exf_getffields interpolation defaults to bilinear for all scalar forcing
33      fields (remains bicubic for wind velocity and stress).  This avoids, e.g.,
34      spurious negative numbers for precipitation and humidity.  Will cause
35      some small numerical differences for integrations using pkg/exf/exf_interp.F.
36    o pkg/ctrl/
37      * Add ctrlvec diagnostics in pack/unpack for nondimensional I/O
38        May be enabled via doPackDiag
39      *  introduce z-scaling of
40         + gradient (doZscalePack) and
41         + control (doZscaleUnpack)
42    o pkg/mdsio/
43      * enable useSingleCpuIO for state estimation (ctrl_pack/unpack) mdsio_gl.F
44      * N.B.: leave tiled I/O for tapelev (i.e. mds...vector)
45    
46    checkpoint57b_post
47    o simplify options in diagnostics_fill arguments (remove weird combinations)
48    o fix MNC coordinate variables so that they now contain per-face index
49      values (instead of xC,xG,yC,yG values) when run with EXCH2 since, in
50      general, EXCH2 grids are only aligned to a "local" coordinate system
51    o test diagnostics pkg in dic_example (no output) and ideal_2D_oce (with ouput)
52    o Implement instantaneous output within pkg diagnostics:
53      setting a negative frequency in data.diagnostics produces
54     "snap-shot" output (as opposed to time-average if freq > 0)
55    o move out off EQUIVALENCE all diagnostics that fizhi does not use ;
56      NOTE: change ptracer diagnostics name: use 2 characters to work with
57            more than 9 tracers. Add also diagnostics of advect & diffus flux.
58    o more CF compliance: convert all MNC 'iter' variables to 'T' so that it
59      becomes the coordinate variable for the 'T' dimension
60    o add CF-style coordinate variables to MNC
61      - just a first cut:  numbers are meaningless on the cubesphere and
62        missing along the T axis but otherwise it works!
63    o add surface flux diagnostics: TAUX, TAUY, TFLUX, TRELAX, TICE, SFLUX, SRELAX
64    o pkg/thSIce: read initial state from 6 files ; allow monitor to use MNC.
65    o add diagnostics of advective & diffusive flux for T & S (pTracers coming soon)
66      this is based directly on what the model compute, so that the content of
67      each diagnostics might be affected by switching options (e.g., implicitDiffusion)
68    o small changes for diagnostics (gad_biharm_?.F, arguments of S/R impldiff.F)
69    o clean up build options files for SunOS, in particular
70      - remove -traditional from xmakedepend
71      - change -xarch=v9 to -xarch=native for f77
72      - restore use of make (not gmake)
73      - add CC=gcc if using g77
74    o changes per discussion of AM, JMC, & EH3 today:
75      - move redundant "grid" variables out of "state" -- in preparation of
76        creating proper CF-style coordinate variables and in recognition
77        that any/all grid variables can be easily copied (eg. w/NCO) from
78        the grid files into any of the other NetCDF files
79      - *always* output grid variables with MDSIO (this will eventually be
80        changed)
81      - output MNC grid file if useMNC is true
82    o every instance of _END_MASTER() has been found and replaced with
83      _END_MASTER( myThid ) in order to satisfy certain picky Sun
84      preprocessors
85    o re-arrange diagnostics pkg initialisation:
86     - allow each package to extend the available diagnostics list
87     - add some checking and fix small problems (multi-threaded, ...)
88     - new S/R diagnostics_fill (replace fill_diagnostics):
89       look through the short list of active diag. (instead of the long list)
90       create function DIAGNOSTICS_IS_ON to tell if a diagnostics is active
91    
92    checkpoint57a_post
93    o this set of changes restores TAMC compatibility
94      tested for global_ocean.90x40x15 adjoint on trough
95      (what a pain)
96    
97    checkpoint57a_pre
98    o some modifs in tools/build_options for sunos
99    o call ctrl_pack for ctrl at end for optimcycle=0
100    
101    checkpoint57
102  o add horizontal bi-harmonic viscosity for vertical velocity  o add horizontal bi-harmonic viscosity for vertical velocity
103    - new parameter viscA4W (defaults to viscA4)    - new parameter viscA4W (defaults to viscA4)
104    - affects only non-hydrostatic code    - affects only non-hydrostatic code

Legend: