/[MITgcm]/MITgcm/doc/tag-index
ViewVC logotype

Diff of /MITgcm/doc/tag-index

Parent Directory Parent Directory | Revision Log Revision Log | View Revision Graph Revision Graph | View Patch Patch

revision 1.413 by edhill, Tue Dec 14 23:00:53 2004 UTC revision 1.447 by edhill, Tue Feb 8 20:39:58 2005 UTC
# Line 3  $Header$ Line 3  $Header$
3      Notes on tags used in MITgcmUV      Notes on tags used in MITgcmUV
4      ==============================      ==============================
5    
6    o add coordinate variables to the MNC output from the diagnostics package
7    o change MNC-flags default value: true when useMNC=TRUE
8    o add a "readgrid_mnc" flag to MNC and give model/src/ini_curvilinear_grid.F
9      the ability (off by default) to read the grid information using MNC
10    o lab_sea: use LSR_ERROR=1.E-12 for testing ; update output.txt
11    o diagnostics: fix a bug (sub-set of levels); keep full precision when averaging
12    o do snap-shot diagnostics at the middle of the time-interval (instead of
13      at the end).
14    o update exp. aim.5l_cs (use default LAND_OPTIONS.h file) and add
15      new test for AIM with thSIce + slab-ocean
16    o cpl_aim+ocn test: update output (optfile & default GMREDI_OPTIONS.h)
17    o move state variable diagnostics to the beginning of the time step ;
18      (note: still needs some work specially for snap-shot diagnostics)
19      duplicate & replace UVELVVEL diagnostics with UV_VEL_C & UV_VEL_Z
20    
21    checkpoint57c_post
22    o Change testing option (-ieee) to get closer agreement between g77 & ifort
23    o generate new output.txt files on faulks with g77 & the new -ieee option
24    checkpoint57c_pre
25    
26    o add "_d 0" in freeze ; change some "FLOAT" to "DFLOAT" and went back (TAF);
27      update output.txt of exp. global_ocean.90x40x15
28    o fix in ini_eos.F (one "_d 0" was missing): now g77 & ifc give much closer
29      results; update global_ocean_pressure & global_ocean.cs32x15 output.txt
30    o add saltFlux(+File) forcing capability with periodicExternalForcing
31    o allow to use pkg diagnostics for GM-Redi & ThSIce output
32    o diagnostics_fill: fill in up to sNx+1 or sNy+1 (if U,V or Z pt) for mnc.
33    o improvements for the MNC output from DIAGNOSTICS:
34      - correct handling of the unlimitied dimension
35      - all dims now have associated coordinate variables
36      - variables located at U, V, and Corner ("Z") points are now written
37        with the correct horzontal dimensions (eg. 'Xp1', 'Yp1') so that
38        *all* data points are output
39    o added seaice_summary.F and removed obsolete ALLOW_SEAICE's from pkg/seaice
40    o added pkg/seaice/seaice_monitor.F
41    o mdsio_readfield.F can now read files visible only to master MPI process.
42    o pkg/seaice: some test code for ice-modified ocean stress
43    o exf_getffields interpolation defaults to bilinear for all scalar forcing
44      fields (remains bicubic for wind velocity and stress).  This avoids, e.g.,
45      spurious negative numbers for precipitation and humidity.  Will cause
46      some small numerical differences for integrations using pkg/exf/exf_interp.F.
47    o pkg/ctrl/
48      * Add ctrlvec diagnostics in pack/unpack for nondimensional I/O
49        May be enabled via doPackDiag
50      *  introduce z-scaling of
51         + gradient (doZscalePack) and
52         + control (doZscaleUnpack)
53    o pkg/mdsio/
54      * enable useSingleCpuIO for state estimation (ctrl_pack/unpack) mdsio_gl.F
55      * N.B.: leave tiled I/O for tapelev (i.e. mds...vector)
56    
57    checkpoint57b_post
58    o simplify options in diagnostics_fill arguments (remove weird combinations)
59    o fix MNC coordinate variables so that they now contain per-face index
60      values (instead of xC,xG,yC,yG values) when run with EXCH2 since, in
61      general, EXCH2 grids are only aligned to a "local" coordinate system
62    o test diagnostics pkg in dic_example (no output) and ideal_2D_oce (with ouput)
63    o Implement instantaneous output within pkg diagnostics:
64      setting a negative frequency in data.diagnostics produces
65     "snap-shot" output (as opposed to time-average if freq > 0)
66    o move out off EQUIVALENCE all diagnostics that fizhi does not use ;
67      NOTE: change ptracer diagnostics name: use 2 characters to work with
68            more than 9 tracers. Add also diagnostics of advect & diffus flux.
69    o more CF compliance: convert all MNC 'iter' variables to 'T' so that it
70      becomes the coordinate variable for the 'T' dimension
71    o add CF-style coordinate variables to MNC
72      - just a first cut:  numbers are meaningless on the cubesphere and
73        missing along the T axis but otherwise it works!
74    o add surface flux diagnostics: TAUX, TAUY, TFLUX, TRELAX, TICE, SFLUX, SRELAX
75    o pkg/thSIce: read initial state from 6 files ; allow monitor to use MNC.
76    o add diagnostics of advective & diffusive flux for T & S (pTracers coming soon)
77      this is based directly on what the model compute, so that the content of
78      each diagnostics might be affected by switching options (e.g., implicitDiffusion)
79    o small changes for diagnostics (gad_biharm_?.F, arguments of S/R impldiff.F)
80    o clean up build options files for SunOS, in particular
81      - remove -traditional from xmakedepend
82      - change -xarch=v9 to -xarch=native for f77
83      - restore use of make (not gmake)
84      - add CC=gcc if using g77
85  o changes per discussion of AM, JMC, & EH3 today:  o changes per discussion of AM, JMC, & EH3 today:
86    - move redundant "grid" variables out of "state" -- in preparation of    - move redundant "grid" variables out of "state" -- in preparation of
87      creating proper CF-style coordinate variables and in recognition      creating proper CF-style coordinate variables and in recognition

Legend: