/[MITgcm]/MITgcm/doc/tag-index
ViewVC logotype

Diff of /MITgcm/doc/tag-index

Parent Directory Parent Directory | Revision Log Revision Log | View Revision Graph Revision Graph | View Patch Patch

revision 1.428 by dimitri, Thu Dec 23 21:28:47 2004 UTC revision 1.453 by jmc, Mon Feb 14 01:03:06 2005 UTC
# Line 3  $Header$ Line 3  $Header$
3      Notes on tags used in MITgcmUV      Notes on tags used in MITgcmUV
4      ==============================      ==============================
5    
6    o allow to use pkg diagnostics for LAND pkg output.
7    o pkg/shap_filt: fix for multi-tiles per face (CS-grid with EXCH2)
8    
9    checkpoint57d_post
10    o pkg/thsice used in the ocean: fix tile Pb related to sIceLoad forcing
11    o modify verification/ideal_2D_oce so that it tests the creation of mnc
12      output from the diagnostics package
13    o temporary fix in EXCH2_UV: add a 3rd call to fix the 24.tiles CS-grid set-up
14    o make genmake2 more portable by using ".$FS" instead of ".f" for more
15      of the test compilations (eg. IBM xlf on Mac OSX w/HFS filesys)
16    o add coordinate variables to the MNC output from the diagnostics package
17    o change MNC-flags default value: true when useMNC=TRUE
18    o add a "readgrid_mnc" flag to MNC and give model/src/ini_curvilinear_grid.F
19      the ability (off by default) to read the grid information using MNC
20    o lab_sea: use LSR_ERROR=1.E-12 for testing ; update output.txt
21    o diagnostics: fix a bug (sub-set of levels); keep full precision when averaging
22    o do snap-shot diagnostics at the middle of the time-interval (instead of
23      at the end).
24    o update exp. aim.5l_cs (use default LAND_OPTIONS.h file) and add
25      new test for AIM with thSIce + slab-ocean
26    o cpl_aim+ocn test: update output (optfile & default GMREDI_OPTIONS.h)
27    o move state variable diagnostics to the beginning of the time step ;
28      (note: still needs some work specially for snap-shot diagnostics)
29      duplicate & replace UVELVVEL diagnostics with UV_VEL_C & UV_VEL_Z
30    
31    checkpoint57c_post
32    o Change testing option (-ieee) to get closer agreement between g77 & ifort
33    o generate new output.txt files on faulks with g77 & the new -ieee option
34    checkpoint57c_pre
35    
36    o add "_d 0" in freeze ; change some "FLOAT" to "DFLOAT" and went back (TAF);
37      update output.txt of exp. global_ocean.90x40x15
38    o fix in ini_eos.F (one "_d 0" was missing): now g77 & ifc give much closer
39      results; update global_ocean_pressure & global_ocean.cs32x15 output.txt
40    o add saltFlux(+File) forcing capability with periodicExternalForcing
41    o allow to use pkg diagnostics for GM-Redi & ThSIce output
42    o diagnostics_fill: fill in up to sNx+1 or sNy+1 (if U,V or Z pt) for mnc.
43    o improvements for the MNC output from DIAGNOSTICS:
44      - correct handling of the unlimitied dimension
45      - all dims now have associated coordinate variables
46      - variables located at U, V, and Corner ("Z") points are now written
47        with the correct horzontal dimensions (eg. 'Xp1', 'Yp1') so that
48        *all* data points are output
49    o added seaice_summary.F and removed obsolete ALLOW_SEAICE's from pkg/seaice
50  o added pkg/seaice/seaice_monitor.F  o added pkg/seaice/seaice_monitor.F
51  o mdsio_readfield.F can now read files visible only to master MPI process.  o mdsio_readfield.F can now read files visible only to master MPI process.
52  o pkg/seaice: some test code for ice-modified ocean stress  o pkg/seaice: some test code for ice-modified ocean stress
# Line 10  o exf_getffields interpolation defaults Line 54  o exf_getffields interpolation defaults
54    fields (remains bicubic for wind velocity and stress).  This avoids, e.g.,    fields (remains bicubic for wind velocity and stress).  This avoids, e.g.,
55    spurious negative numbers for precipitation and humidity.  Will cause    spurious negative numbers for precipitation and humidity.  Will cause
56    some small numerical differences for integrations using pkg/exf/exf_interp.F.    some small numerical differences for integrations using pkg/exf/exf_interp.F.
57    o pkg/ctrl/
58      * Add ctrlvec diagnostics in pack/unpack for nondimensional I/O
59        May be enabled via doPackDiag
60      *  introduce z-scaling of
61         + gradient (doZscalePack) and
62         + control (doZscaleUnpack)
63    o pkg/mdsio/
64      * enable useSingleCpuIO for state estimation (ctrl_pack/unpack) mdsio_gl.F
65      * N.B.: leave tiled I/O for tapelev (i.e. mds...vector)
66    
67  checkpoint57b_post  checkpoint57b_post
68  o simplify options in diagnostics_fill arguments (remove weird combinations)  o simplify options in diagnostics_fill arguments (remove weird combinations)

Legend:
Removed from v.1.428  
changed lines
  Added in v.1.453

  ViewVC Help
Powered by ViewVC 1.1.22