/[MITgcm]/MITgcm/doc/tag-index
ViewVC logotype

Diff of /MITgcm/doc/tag-index

Parent Directory Parent Directory | Revision Log Revision Log | View Revision Graph Revision Graph | View Patch Patch

revision 1.407 by heimbach, Thu Dec 9 15:37:25 2004 UTC revision 1.418 by dimitri, Fri Dec 17 19:17:56 2004 UTC
# Line 3  $Header$ Line 3  $Header$
3      Notes on tags used in MITgcmUV      Notes on tags used in MITgcmUV
4      ==============================      ==============================
5    
6    o add surface flux diagnostics: TAUX, TAUY, TFLUX, TRELAX, TICE, SFLUX, SRELAX
7    o pkg/thSIce: read initial state from 6 files ; allow monitor to use MNC.
8    o add diagnostics of advective & diffusive flux for T & S (pTracers coming soon)
9      this is based directly on what the model compute, so that the content of
10      each diagnostics might be affected by switching options (e.g., implicitDiffusion)
11    o small changes for diagnostics (gad_biharm_?.F, arguments of S/R impldiff.F)
12    o clean up build options files for SunOS, in particular
13      - remove -traditional from xmakedepend
14      - change -xarch=v9 to -xarch=native for f77
15      - restore use of make (not gmake)
16      - add CC=gcc if using g77
17    o changes per discussion of AM, JMC, & EH3 today:
18      - move redundant "grid" variables out of "state" -- in preparation of
19        creating proper CF-style coordinate variables and in recognition
20        that any/all grid variables can be easily copied (eg. w/NCO) from
21        the grid files into any of the other NetCDF files
22      - *always* output grid variables with MDSIO (this will eventually be
23        changed)
24      - output MNC grid file if useMNC is true
25    o every instance of _END_MASTER() has been found and replaced with
26      _END_MASTER( myThid ) in order to satisfy certain picky Sun
27      preprocessors
28    o re-arrange diagnostics pkg initialisation:
29     - allow each package to extend the available diagnostics list
30     - add some checking and fix small problems (multi-threaded, ...)
31     - new S/R diagnostics_fill (replace fill_diagnostics):
32       look through the short list of active diag. (instead of the long list)
33       create function DIAGNOSTICS_IS_ON to tell if a diagnostics is active
34    
35    checkpoint57a_post
36    o this set of changes restores TAMC compatibility
37      tested for global_ocean.90x40x15 adjoint on trough
38      (what a pain)
39    
40    checkpoint57a_pre
41    o some modifs in tools/build_options for sunos
42    o call ctrl_pack for ctrl at end for optimcycle=0
43    
44    checkpoint57
45  o add horizontal bi-harmonic viscosity for vertical velocity  o add horizontal bi-harmonic viscosity for vertical velocity
46    - new parameter viscA4W (defaults to viscA4)    - new parameter viscA4W (defaults to viscA4)
47    - affects only non-hydrostatic code    - affects only non-hydrostatic code

Legend:
Removed from v.1.407  
changed lines
  Added in v.1.418

  ViewVC Help
Powered by ViewVC 1.1.22