/[MITgcm]/MITgcm/doc/tag-index
ViewVC logotype

Diff of /MITgcm/doc/tag-index

Parent Directory Parent Directory | Revision Log Revision Log | View Revision Graph Revision Graph | View Patch Patch

revision 1.408 by jmc, Thu Dec 9 17:41:09 2004 UTC revision 1.428 by dimitri, Thu Dec 23 21:28:47 2004 UTC
# Line 3  $Header$ Line 3  $Header$
3      Notes on tags used in MITgcmUV      Notes on tags used in MITgcmUV
4      ==============================      ==============================
5    
6    o added pkg/seaice/seaice_monitor.F
7    o mdsio_readfield.F can now read files visible only to master MPI process.
8    o pkg/seaice: some test code for ice-modified ocean stress
9    o exf_getffields interpolation defaults to bilinear for all scalar forcing
10      fields (remains bicubic for wind velocity and stress).  This avoids, e.g.,
11      spurious negative numbers for precipitation and humidity.  Will cause
12      some small numerical differences for integrations using pkg/exf/exf_interp.F.
13    
14    checkpoint57b_post
15    o simplify options in diagnostics_fill arguments (remove weird combinations)
16    o fix MNC coordinate variables so that they now contain per-face index
17      values (instead of xC,xG,yC,yG values) when run with EXCH2 since, in
18      general, EXCH2 grids are only aligned to a "local" coordinate system
19    o test diagnostics pkg in dic_example (no output) and ideal_2D_oce (with ouput)
20    o Implement instantaneous output within pkg diagnostics:
21      setting a negative frequency in data.diagnostics produces
22     "snap-shot" output (as opposed to time-average if freq > 0)
23    o move out off EQUIVALENCE all diagnostics that fizhi does not use ;
24      NOTE: change ptracer diagnostics name: use 2 characters to work with
25            more than 9 tracers. Add also diagnostics of advect & diffus flux.
26    o more CF compliance: convert all MNC 'iter' variables to 'T' so that it
27      becomes the coordinate variable for the 'T' dimension
28    o add CF-style coordinate variables to MNC
29      - just a first cut:  numbers are meaningless on the cubesphere and
30        missing along the T axis but otherwise it works!
31    o add surface flux diagnostics: TAUX, TAUY, TFLUX, TRELAX, TICE, SFLUX, SRELAX
32    o pkg/thSIce: read initial state from 6 files ; allow monitor to use MNC.
33    o add diagnostics of advective & diffusive flux for T & S (pTracers coming soon)
34      this is based directly on what the model compute, so that the content of
35      each diagnostics might be affected by switching options (e.g., implicitDiffusion)
36    o small changes for diagnostics (gad_biharm_?.F, arguments of S/R impldiff.F)
37    o clean up build options files for SunOS, in particular
38      - remove -traditional from xmakedepend
39      - change -xarch=v9 to -xarch=native for f77
40      - restore use of make (not gmake)
41      - add CC=gcc if using g77
42    o changes per discussion of AM, JMC, & EH3 today:
43      - move redundant "grid" variables out of "state" -- in preparation of
44        creating proper CF-style coordinate variables and in recognition
45        that any/all grid variables can be easily copied (eg. w/NCO) from
46        the grid files into any of the other NetCDF files
47      - *always* output grid variables with MDSIO (this will eventually be
48        changed)
49      - output MNC grid file if useMNC is true
50    o every instance of _END_MASTER() has been found and replaced with
51      _END_MASTER( myThid ) in order to satisfy certain picky Sun
52      preprocessors
53    o re-arrange diagnostics pkg initialisation:
54     - allow each package to extend the available diagnostics list
55     - add some checking and fix small problems (multi-threaded, ...)
56     - new S/R diagnostics_fill (replace fill_diagnostics):
57       look through the short list of active diag. (instead of the long list)
58       create function DIAGNOSTICS_IS_ON to tell if a diagnostics is active
59    
60    checkpoint57a_post
61    o this set of changes restores TAMC compatibility
62      tested for global_ocean.90x40x15 adjoint on trough
63      (what a pain)
64    
65    checkpoint57a_pre
66    o some modifs in tools/build_options for sunos
67    o call ctrl_pack for ctrl at end for optimcycle=0
68    
69  checkpoint57  checkpoint57
70  o add horizontal bi-harmonic viscosity for vertical velocity  o add horizontal bi-harmonic viscosity for vertical velocity
71    - new parameter viscA4W (defaults to viscA4)    - new parameter viscA4W (defaults to viscA4)

Legend:
Removed from v.1.408  
changed lines
  Added in v.1.428

  ViewVC Help
Powered by ViewVC 1.1.22