/[MITgcm]/MITgcm/doc/tag-index
ViewVC logotype

Diff of /MITgcm/doc/tag-index

Parent Directory Parent Directory | Revision Log Revision Log | View Revision Graph Revision Graph | View Patch Patch

revision 1.418 by dimitri, Fri Dec 17 19:17:56 2004 UTC revision 1.426 by dimitri, Wed Dec 22 00:49:36 2004 UTC
# Line 3  $Header$ Line 3  $Header$
3      Notes on tags used in MITgcmUV      Notes on tags used in MITgcmUV
4      ==============================      ==============================
5    
6    o pkg/seaice: some test code for ice-modified ocean stress
7    o exf_getffields interpolation defaults to bilinear for all scalar forcing
8      fields (remains bicubic for wind velocity and stress).  This avoids, e.g.,
9      spurious negative numbers for precipitation and humidity.  Will cause
10      some small numerical differences for integrations using pkg/exf/exf_interp.F.
11    
12    checkpoint57b_post
13    o simplify options in diagnostics_fill arguments (remove weird combinations)
14    o fix MNC coordinate variables so that they now contain per-face index
15      values (instead of xC,xG,yC,yG values) when run with EXCH2 since, in
16      general, EXCH2 grids are only aligned to a "local" coordinate system
17    o test diagnostics pkg in dic_example (no output) and ideal_2D_oce (with ouput)
18    o Implement instantaneous output within pkg diagnostics:
19      setting a negative frequency in data.diagnostics produces
20     "snap-shot" output (as opposed to time-average if freq > 0)
21    o move out off EQUIVALENCE all diagnostics that fizhi does not use ;
22      NOTE: change ptracer diagnostics name: use 2 characters to work with
23            more than 9 tracers. Add also diagnostics of advect & diffus flux.
24    o more CF compliance: convert all MNC 'iter' variables to 'T' so that it
25      becomes the coordinate variable for the 'T' dimension
26    o add CF-style coordinate variables to MNC
27      - just a first cut:  numbers are meaningless on the cubesphere and
28        missing along the T axis but otherwise it works!
29  o add surface flux diagnostics: TAUX, TAUY, TFLUX, TRELAX, TICE, SFLUX, SRELAX  o add surface flux diagnostics: TAUX, TAUY, TFLUX, TRELAX, TICE, SFLUX, SRELAX
30  o pkg/thSIce: read initial state from 6 files ; allow monitor to use MNC.  o pkg/thSIce: read initial state from 6 files ; allow monitor to use MNC.
31  o add diagnostics of advective & diffusive flux for T & S (pTracers coming soon)  o add diagnostics of advective & diffusive flux for T & S (pTracers coming soon)

Legend: