/[MITgcm]/MITgcm/doc/tag-index
ViewVC logotype

Diff of /MITgcm/doc/tag-index

Parent Directory Parent Directory | Revision Log Revision Log | View Revision Graph Revision Graph | View Patch Patch

revision 1.433 by heimbach, Tue Jan 4 22:08:07 2005 UTC revision 1.439 by jmc, Fri Jan 28 01:32:09 2005 UTC
# Line 3  $Header$ Line 3  $Header$
3      Notes on tags used in MITgcmUV      Notes on tags used in MITgcmUV
4      ==============================      ==============================
5    
6    o move state variable diagnostics to the beginning of the time step ;
7      (note: still needs some work specially for snap-shot diagnostics)
8      duplicate & replace UVELVVEL diagnostics with UV_VEL_C & UV_VEL_Z
9    
10    checkpoint57c_post
11    o Change testing option (-ieee) to get closer agreement between g77 & ifort
12    o generate new output.txt files on faulks with g77 & the new -ieee option
13    checkpoint57c_pre
14    
15    o add "_d 0" in freeze ; change some "FLOAT" to "DFLOAT" and went back (TAF);
16      update output.txt of exp. global_ocean.90x40x15
17    o fix in ini_eos.F (one "_d 0" was missing): now g77 & ifc give much closer
18      results; update global_ocean_pressure & global_ocean.cs32x15 output.txt
19  o add saltFlux(+File) forcing capability with periodicExternalForcing  o add saltFlux(+File) forcing capability with periodicExternalForcing
20  o allow to use pkg diagnostics for GM-Redi & ThSIce output  o allow to use pkg diagnostics for GM-Redi & ThSIce output
21  o diagnostics_fill: fill in up to sNx+1 or sNy+1 (if U,V or Z pt) for mnc.  o diagnostics_fill: fill in up to sNx+1 or sNy+1 (if U,V or Z pt) for mnc.
# Line 20  o exf_getffields interpolation defaults Line 33  o exf_getffields interpolation defaults
33    fields (remains bicubic for wind velocity and stress).  This avoids, e.g.,    fields (remains bicubic for wind velocity and stress).  This avoids, e.g.,
34    spurious negative numbers for precipitation and humidity.  Will cause    spurious negative numbers for precipitation and humidity.  Will cause
35    some small numerical differences for integrations using pkg/exf/exf_interp.F.    some small numerical differences for integrations using pkg/exf/exf_interp.F.
36  o Add ctrlvec diagnostics in pack/unpack for nondimensional I/O  o pkg/ctrl/
37    May be enabled via doPackDiag    * Add ctrlvec diagnostics in pack/unpack for nondimensional I/O
38        May be enabled via doPackDiag
39      *  introduce z-scaling of
40         + gradient (doZscalePack) and
41         + control (doZscaleUnpack)
42    o pkg/mdsio/
43      * enable useSingleCpuIO for state estimation (ctrl_pack/unpack) mdsio_gl.F
44      * N.B.: leave tiled I/O for tapelev (i.e. mds...vector)
45    
46  checkpoint57b_post  checkpoint57b_post
47  o simplify options in diagnostics_fill arguments (remove weird combinations)  o simplify options in diagnostics_fill arguments (remove weird combinations)

Legend:
Removed from v.1.433  
changed lines
  Added in v.1.439

  ViewVC Help
Powered by ViewVC 1.1.22